... ... @@ -64,7 +64,7 @@
64 64  )))
65 65  
66 66  * (((
67 -STM32L072CZT6 MCU
67 +STM32L072xxxx MCU
68 68  )))
69 69  * (((
70 70  SX1276/78 Wireless Chip 
... ... @@ -186,7 +186,6 @@
186 186  * Firmware upgradable via program port
187 187  * Counting
188 188  
189 -
190 190  == 1.4  Applications ==
191 191  
192 192  
... ... @@ -197,7 +197,6 @@
197 197  * Smart Cities
198 198  * Smart Factory
199 199  
200 -
201 201  == 1.5 Hardware Variants ==
202 202  
203 203  
... ... @@ -212,7 +212,6 @@
212 212  * 1 x Counting Port
213 213  )))
214 214  
215 -
216 216  = 2. Power ON Device =
217 217  
218 218  
... ... @@ -310,8 +310,6 @@
310 310  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
311 311  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
312 312  
313 -
314 -
315 315  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
316 316  
317 317  
... ... @@ -368,8 +368,6 @@
368 368  ** DO1 is high in case there is load between DO1 and V+.
369 369  ** DO1 LED is off in both case
370 370  
371 -
372 -
373 373  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
374 374  
375 375  
... ... @@ -775,7 +775,6 @@
775 775  
776 776  * (% style="color:blue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
777 777  
778 -
779 779  === 3.4.1 Common Commands ===
780 780  
781 781  
... ... @@ -1253,14 +1253,14 @@
1253 1253  
1254 1254  
1255 1255  
1256 -==== 3.4.2.20 Reset save DR DO state ====
1248 +==== 3.4.2.20 Reset save RO DO state ====
1257 1257  
1258 1258  
1259 1259  * (% style="color:#037691" %)**AT Command:**
1260 1260  
1261 -(% style="color:blue" %)**AT+RODORET=1    **(%%)~/~/ RODO will close when the device joining the network. (default)
1253 +(% style="color:blue" %)**AT+RODORESET=1    **(%%)~/~/ RODO will close when the device joining the network. (default)
1262 1262  
1263 -(% style="color:blue" %)**AT+RODORET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1255 +(% style="color:blue" %)**AT+RODORESET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1264 1264  
1265 1265  
1266 1266  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
... ... @@ -1546,8 +1546,10 @@
1546 1546  === 3.6.3 Digital Output Port: DO1/DO2 /DO3 ===
1547 1547  
1548 1548  
1549 -NPN output: GND or Float. Max voltage can apply to output pin is 36v.
1541 +**NPN output**: GND or Float. Max voltage can apply to output pin is 36v.
1550 1550  
1543 +Note: DO pins go to float when device is power off.
1544 +
1551 1551  [[image:1653357531600-905.png]]
1552 1552  
1553 1553  
... ... @@ -1588,7 +1588,9 @@
1588 1588  
1589 1589  
1590 1590  (((
1591 -The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below:
1585 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below:
1586 +
1587 +**Note**: RO pins go to Open(NO) when device is power off.
1592 1592  )))
1593 1593  
1594 1594  [[image:image-20220524100215-9.png]]
... ... @@ -2131,11 +2131,13 @@
2131 2131  [[image:image-20221006170630-1.png||height="610" width="945"]]
2132 2132  
2133 2133  
2134 -== 5.8 Can LT22222 save RO state? ==
2130 +== 5.8 Can LT22222-L save RO state? ==
2135 2135  
2132 +
2136 2136  Firmware version needs to be no less than 1.6.0.
2137 2137  
2138 2138  
2136 +
2139 2139  = 6. Trouble Shooting =
2140 2140  
2141 2141  
... ... @@ -2198,7 +2198,6 @@
2198 2198  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2199 2199  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2200 2200  
2201 -
2202 2202  = 8. Packing Info =
2203 2203  
2204 2204  
... ... @@ -2216,7 +2216,6 @@
2216 2216  * Package Size / pcs : 14.5 x 8 x 5 cm
2217 2217  * Weight / pcs : 170g
2218 2218  
2219 -
2220 2220  = 9. Support =
2221 2221  
2222 2222  
... ... @@ -2227,7 +2227,6 @@
2227 2227  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
2228 2228  
2229 2229  
2230 -
2231 2231  
2232 2232  )))
2233 2233  
image-20221112174847-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +102.6 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved