Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,7 +15,6 @@ 15 15 16 16 = 1.Introduction = 17 17 18 - 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( ... ... @@ -54,7 +54,6 @@ 54 54 55 55 ))) 56 56 57 - 58 58 == 1.2 Specifications == 59 59 60 60 ((( ... ... @@ -64,7 +64,7 @@ 64 64 ))) 65 65 66 66 * ((( 67 -STM32L072 CZT6MCU65 +STM32L072xxxx MCU 68 68 ))) 69 69 * ((( 70 70 SX1276/78 Wireless Chip ... ... @@ -171,7 +171,6 @@ 171 171 Packet engine up to 256 bytes with CRC. 172 172 173 173 174 - 175 175 176 176 ))) 177 177 ... ... @@ -232,10 +232,8 @@ 232 232 [[image:1653297104069-180.png]] 233 233 234 234 235 - 236 236 = 3. Operation Mode = 237 237 238 - 239 239 == 3.1 How it works? == 240 240 241 241 ... ... @@ -248,7 +248,6 @@ 248 248 ))) 249 249 250 250 251 - 252 252 == 3.2 Example to join LoRaWAN network == 253 253 254 254 ... ... @@ -300,7 +300,6 @@ 300 300 [[image:1653298044601-602.png||height="405" width="709"]] 301 301 302 302 303 - 304 304 == 3.3 Uplink Payload == 305 305 306 306 ... ... @@ -315,7 +315,6 @@ 315 315 316 316 317 317 318 - 319 319 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 320 320 321 321 ... ... @@ -374,7 +374,6 @@ 374 374 375 375 376 376 377 - 378 378 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 379 379 380 380 ... ... @@ -448,7 +448,6 @@ 448 448 ))) 449 449 450 450 451 - 452 452 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 453 453 454 454 ... ... @@ -495,7 +495,6 @@ 495 495 ))) 496 496 497 497 498 - 499 499 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 500 500 501 501 ... ... @@ -564,7 +564,6 @@ 564 564 ))) 565 565 566 566 567 - 568 568 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 569 569 570 570 ... ... @@ -612,7 +612,6 @@ 612 612 ))) 613 613 614 614 615 - 616 616 === 3.3.6 AT+ADDMOD~=6. (Trigger Mode, Optional) === 617 617 618 618 ... ... @@ -667,7 +667,6 @@ 667 667 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 668 668 669 669 670 - 671 671 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 672 672 673 673 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -728,7 +728,6 @@ 728 728 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 729 729 730 730 731 - 732 732 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 733 733 734 734 [[image:image-20220524090456-4.png]] ... ... @@ -742,7 +742,6 @@ 742 742 00000101: Means both DI1 and DI2 trigger are enabled. 743 743 744 744 745 - 746 746 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 747 747 748 748 Downlink command to poll MOD6 status: ... ... @@ -752,7 +752,6 @@ 752 752 When device got this command, it will send the MOD6 payload. 753 753 754 754 755 - 756 756 === 3.3.7 Payload Decoder === 757 757 758 758 ((( ... ... @@ -762,7 +762,6 @@ 762 762 ))) 763 763 764 764 765 - 766 766 == 3.4 Configure LT via AT or Downlink == 767 767 768 768 ... ... @@ -790,10 +790,8 @@ 790 790 ))) 791 791 792 792 793 - 794 794 === 3.4.2 Sensor related commands === 795 795 796 - 797 797 ==== 3.4.2.1 Set Transmit Interval ==== 798 798 799 799 ... ... @@ -869,7 +869,6 @@ 869 869 870 870 871 871 872 - 873 873 ==== 3.4.2.5 Poll trigger settings ==== 874 874 875 875 ... ... @@ -952,7 +952,7 @@ 952 952 953 953 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 954 954 955 -(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG 1=aa,0x(bb cc)934 +(% style="color:blue" %)**0x09 02 aa bb cc ** (%%)~/~/ same as AT+TRIG2=aa,0x(bb cc) 956 956 957 957 958 958 ... ... @@ -1084,6 +1084,14 @@ 1084 1084 1085 1085 Latching time. Unit: ms 1086 1086 1066 + 1067 +(% style="color:red" %)**Note: ** 1068 + 1069 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1070 + 1071 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1072 + 1073 + 1087 1087 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1088 1088 1089 1089 ... ... @@ -1107,7 +1107,7 @@ 1107 1107 1108 1108 1109 1109 1110 -==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1097 +==== 3.4.2. 14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1111 1111 1112 1112 1113 1113 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1136,7 +1136,6 @@ 1136 1136 1137 1137 1138 1138 1139 - 1140 1140 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1141 1141 1142 1142 ... ... @@ -1168,12 +1168,20 @@ 1168 1168 1169 1169 (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1170 1170 1157 + 1158 +(% style="color:red" %)**Note:** 1159 + 1160 + Since Firmware v1.6.0, the latch time support 4 bytes and 2 bytes 1161 + 1162 + Before Firmwre v1.6.0 the latch time only suport 2 bytes. 1163 + 1164 + 1171 1171 (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1172 1172 1173 1173 1174 1174 **Example payload:** 1175 1175 1176 -**~1. 05 01 11 07 D** 1170 +**~1. 05 01 11 07 D0** 1177 1177 1178 1178 Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1179 1179 ... ... @@ -1259,14 +1259,14 @@ 1259 1259 1260 1260 1261 1261 1262 -==== 3.4.2.20 Reset save DR DO state ====1256 +==== 3.4.2.20 Reset save RO DO state ==== 1263 1263 1264 1264 1265 1265 * (% style="color:#037691" %)**AT Command:** 1266 1266 1267 -(% style="color:blue" %)**AT+RODORET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1261 +(% style="color:blue" %)**AT+RODORESET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1268 1268 1269 -(% style="color:blue" %)**AT+RODORET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1263 +(% style="color:blue" %)**AT+RODORESET=0 **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1270 1270 1271 1271 1272 1272 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** ... ... @@ -1308,7 +1308,6 @@ 1308 1308 1309 1309 1310 1310 1311 - 1312 1312 ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1313 1313 1314 1314 ... ... @@ -1325,7 +1325,6 @@ 1325 1325 1326 1326 1327 1327 1328 - 1329 1329 ==== 3.4.2.25 Copy downlink to uplink ==== 1330 1330 1331 1331 ... ... @@ -1364,7 +1364,6 @@ 1364 1364 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1365 1365 1366 1366 1367 - 1368 1368 == 3.5 Integrate with Mydevice == 1369 1369 1370 1370 ... ... @@ -1414,10 +1414,8 @@ 1414 1414 [[image:image-20220524094909-5.png||height="341" width="734"]] 1415 1415 1416 1416 1417 - 1418 1418 == 3.6 Interface Detail == 1419 1419 1420 - 1421 1421 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1422 1422 1423 1423 ... ... @@ -1426,7 +1426,6 @@ 1426 1426 [[image:1653356991268-289.png]] 1427 1427 1428 1428 1429 - 1430 1430 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1431 1431 1432 1432 ... ... @@ -1483,8 +1483,6 @@ 1483 1483 1484 1484 ((( 1485 1485 1486 - 1487 - 1488 1488 ))) 1489 1489 1490 1490 ((( ... ... @@ -1516,8 +1516,6 @@ 1516 1516 1517 1517 ((( 1518 1518 1519 - 1520 - 1521 1521 ))) 1522 1522 1523 1523 ((( ... ... @@ -1548,16 +1548,16 @@ 1548 1548 ))) 1549 1549 1550 1550 1551 - 1552 1552 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1553 1553 1554 1554 1555 -NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1538 +**NPN output**: GND or Float. Max voltage can apply to output pin is 36v. 1556 1556 1540 +Note: DO pins go to float when device is power off. 1541 + 1557 1557 [[image:1653357531600-905.png]] 1558 1558 1559 1559 1560 - 1561 1561 === 3.6.4 Analog Input Interface === 1562 1562 1563 1563 ... ... @@ -1589,12 +1589,13 @@ 1589 1589 [[image:1653357648330-671.png||height="155" width="733"]] 1590 1590 1591 1591 1592 - 1593 1593 === 3.6.5 Relay Output === 1594 1594 1595 1595 1596 1596 ((( 1597 -The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1580 +The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device's Power Line to in serial of RO1_1 and RO_2. Such as below: 1581 + 1582 +**Note**: RO pins go to Open(NO) when device is power off. 1598 1598 ))) 1599 1599 1600 1600 [[image:image-20220524100215-9.png]] ... ... @@ -1603,7 +1603,6 @@ 1603 1603 [[image:image-20220524100215-10.png||height="382" width="723"]] 1604 1604 1605 1605 1606 - 1607 1607 == 3.7 LEDs Indicators == 1608 1608 1609 1609 ... ... @@ -1610,10 +1610,8 @@ 1610 1610 [[image:image-20220524100748-11.png]] 1611 1611 1612 1612 1613 - 1614 1614 = 4. Use AT Command = 1615 1615 1616 - 1617 1617 == 4.1 Access AT Command == 1618 1618 1619 1619 ... ... @@ -1824,10 +1824,8 @@ 1824 1824 ))) 1825 1825 1826 1826 1827 - 1828 1828 == 4.2 Common AT Command Sequence == 1829 1829 1830 - 1831 1831 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1832 1832 1833 1833 ((( ... ... @@ -1872,7 +1872,6 @@ 1872 1872 ))) 1873 1873 1874 1874 1875 - 1876 1876 === 4.2.2 Single-channel ABP mode (Use with LG01/LG02) === 1877 1877 1878 1878 ((( ... ... @@ -1958,7 +1958,6 @@ 1958 1958 1959 1959 ))) 1960 1960 1961 - 1962 1962 === 4.2.3 Change to Class A === 1963 1963 1964 1964 ... ... @@ -1970,10 +1970,8 @@ 1970 1970 ))) 1971 1971 1972 1972 1973 - 1974 1974 = 5. FAQ = 1975 1975 1976 - 1977 1977 == 5.1 How to upgrade the image? == 1978 1978 1979 1979 ... ... @@ -2017,8 +2017,6 @@ 2017 2017 2018 2018 ((( 2019 2019 ((( 2020 - 2021 - 2022 2022 == 5.2 How to change the LoRa Frequency Bands/Region? == 2023 2023 2024 2024 ... ... @@ -2032,7 +2032,6 @@ 2032 2032 ((( 2033 2033 2034 2034 2035 - 2036 2036 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2037 2037 2038 2038 ... ... @@ -2096,7 +2096,6 @@ 2096 2096 [[image:1653360498588-932.png||height="485" width="726"]] 2097 2097 2098 2098 2099 - 2100 2100 == 5.4 Can I see counting event in Serial? == 2101 2101 2102 2102 ... ... @@ -2104,13 +2104,11 @@ 2104 2104 User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 2105 2105 2106 2106 2107 - 2108 2108 == 5.5 Can i use point to point communication for LT-22222-L? == 2109 2109 2110 2110 2111 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https:// www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].2082 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://github.com/dragino/LT-22222-L/releases]]. 2112 2112 2113 - 2114 2114 2115 2115 ))) 2116 2116 ... ... @@ -2127,7 +2127,6 @@ 2127 2127 After restart, the status before power failure will be read from flash. 2128 2128 2129 2129 2130 - 2131 2131 == 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2132 2132 2133 2133 ... ... @@ -2137,10 +2137,13 @@ 2137 2137 [[image:image-20221006170630-1.png||height="610" width="945"]] 2138 2138 2139 2139 2109 +== 5.8 Can LT22222-L save RO state? == 2140 2140 2141 -= 6. Trouble Shooting = 2142 2142 2143 - 2112 +Firmware version needs to be no less than 1.6.0. 2113 + 2114 + 2115 += 6. Trouble Shooting = 2144 2144 ))) 2145 2145 2146 2146 ((( ... ... @@ -2158,7 +2158,6 @@ 2158 2158 ((( 2159 2159 2160 2160 2161 - 2162 2162 == 6.2 Have trouble to upload image. == 2163 2163 2164 2164 ... ... @@ -2171,7 +2171,6 @@ 2171 2171 ((( 2172 2172 2173 2173 2174 - 2175 2175 == 6.3 Why I can't join TTN in US915 /AU915 bands? == 2176 2176 2177 2177 ... ... @@ -2182,7 +2182,6 @@ 2182 2182 ))) 2183 2183 2184 2184 2185 - 2186 2186 = 7. Order Info = 2187 2187 2188 2188 ... ... @@ -2231,7 +2231,6 @@ 2231 2231 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2232 2232 2233 2233 2234 - 2235 2235 2236 2236 ))) 2237 2237 ... ... @@ -2241,3 +2241,5 @@ 2241 2241 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2242 2242 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2243 2243 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2212 + 2213 +
- image-20221112174847-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +102.6 KB - Content