<
From version < 102.4 >
edited by Xiaoling
on 2022/10/29 10:05
To version < 102.2 >
edited by Xiaoling
on 2022/10/29 09:42
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -218,6 +218,7 @@
218 218  
219 219  
220 220  
221 +
221 221  = 2. Power ON Device =
222 222  
223 223  
... ... @@ -315,6 +315,9 @@
315 315  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
316 316  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
317 317  
319 +
320 +
321 +
318 318  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
319 319  
320 320  
... ... @@ -371,6 +371,9 @@
371 371  ** DO1 is high in case there is load between DO1 and V+.
372 372  ** DO1 LED is off in both case
373 373  
378 +
379 +
380 +
374 374  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
375 375  
376 376  
... ... @@ -778,7 +778,6 @@
778 778  
779 779  
780 780  
781 -
782 782  === 3.4.1 Common Commands ===
783 783  
784 784  
... ... @@ -798,7 +798,7 @@
798 798  
799 799  * (% style="color:#037691" %)**AT Command:**
800 800  
801 -(% style="color:blue" %)**AT+TDC=N **
807 +**(% style="color:blue" %)AT+TDC=N **
802 802  
803 803  
804 804  **Example: **AT+TDC=30000. Means set interval to 30 seconds
... ... @@ -806,10 +806,11 @@
806 806  
807 807  * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
808 808  
809 -(% style="color:blue" %)**0x01 aa bb cc  **(%%)** ~/~/ Same as AT+TDC=0x(aa bb cc)**
815 +**(% style="color:blue" %)0x01 aa bb cc  (%%)   ~/~/ Same as AT+TDC=0x(aa bb cc)**
810 810  
811 811  
812 812  
819 +
813 813  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
814 814  
815 815  
... ... @@ -817,7 +817,7 @@
817 817  
818 818  * (% style="color:#037691" %)**AT Command:**
819 819  
820 -(% style="color:blue" %)**AT+MOD=N  **
827 +**(% style="color:blue" %)AT+MOD=N  **
821 821  
822 822  
823 823  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
... ... @@ -825,10 +825,11 @@
825 825  
826 826  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
827 827  
828 -(% style="color:blue" %)**0x0A aa  **(%%)** ** ~/~/ Same as AT+MOD=aa
835 +**(% style="color:blue" %)0x0A aa  (%%)  ** ~/~/ Same as AT+MOD=aa
829 829  
830 830  
831 831  
839 +
832 832  ==== 3.4.2.3 Poll an uplink ====
833 833  
834 834  
... ... @@ -839,7 +839,7 @@
839 839  
840 840  * (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
841 841  
842 -(% style="color:blue" %)**0x08 FF  **(%%)** **~/~/ Poll an uplink
850 +**(% style="color:blue" %)0x08 FF  (%%)   **~/~/ Poll an uplink
843 843  
844 844  
845 845  **Example**: 0x08FF, ask device to send an Uplink
... ... @@ -846,6 +846,7 @@
846 846  
847 847  
848 848  
857 +
849 849  ==== 3.4.2.4 Enable Trigger Mode ====
850 850  
851 851  
... ... @@ -853,16 +853,16 @@
853 853  
854 854  * (% style="color:#037691" %)**AT Command:**
855 855  
856 -(% style="color:blue" %)**AT+ADDMOD6=1 or 0**
865 +**(% style="color:blue" %)AT+ADDMOD6=1 or 0**
857 857  
858 -(% style="color:red" %)**1:** (%%)Enable Trigger Mode
867 +**(% style="color:red" %)1:** Enable Trigger Mode
859 859  
860 -(% style="color:red" %)**0: **(%%)Disable Trigger Mode
869 +**(% style="color:red" %)0: **Disable Trigger Mode
861 861  
862 862  
863 863  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
864 864  
865 -(% style="color:blue" %)**0x0A 06 aa    **(%%) ~/~/ Same as AT+ADDMOD6=aa
874 +**(% style="color:blue" %)0x0A 06 aa    **(%%) ~/~/ Same as AT+ADDMOD6=aa
866 866  
867 867  
868 868  
... ... @@ -879,10 +879,11 @@
879 879  
880 880  * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
881 881  
882 -(% style="color:blue" %)**0xAB 06  ** (%%) ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
891 +**(% style="color:blue" %)0xAB 06  ** (%%) ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
883 883  
884 884  
885 885  
895 +
886 886  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
887 887  
888 888  
... ... @@ -890,7 +890,7 @@
890 890  
891 891  * (% style="color:#037691" %)**AT Command:**
892 892  
893 -(% style="color:blue" %)**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
903 +**Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
894 894  
895 895  
896 896  **Example:**
... ... @@ -899,10 +899,11 @@
899 899  
900 900  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
901 901  
902 -(% style="color:blue" %)**0xAA 02 aa bb   ** (%%) ~/~/ Same as AT+DTRI=aa,bb
912 +**(% style="color:blue" %)0xAA 02 aa bb   ** (%%) ~/~/ Same as AT+DTRI=aa,bb
903 903  
904 904  
905 905  
916 +
906 906  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
907 907  
908 908  
... ... @@ -910,11 +910,11 @@
910 910  
911 911  * (% style="color:#037691" %)**AT Command:**
912 912  
913 -(% style="color:blue" %)**AT+TRIG1=a,b**
924 +**(% style="color:blue" %)AT+TRIG1=a,b**
914 914  
915 -(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
926 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
916 916  
917 -(% style="color:red" %)**b :** (%%)delay timing.
928 +b : delay timing.
918 918  
919 919  
920 920  **Example:**
... ... @@ -923,11 +923,8 @@
923 923  
924 924  
925 925  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
937 +* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
926 926  
927 -(% style="color:blue" %)**0x09 01 aa bb cc    ** (%%) ~/~/ same as AT+TRIG1=aa,0x(bb cc)
928 -
929 -
930 -
931 931  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
932 932  
933 933  
... ... @@ -935,13 +935,14 @@
935 935  
936 936  * (% style="color:#037691" %)**AT Command:**
937 937  
938 -(% style="color:blue" %)**AT+TRIG2=a,b**
946 +**AT+TRIG2=a,b**
939 939  
940 -(% style="color:red" %)**a :** (%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
941 941  
942 -(% style="color:red" %)**b :** (%%)delay timing.
949 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
943 943  
951 +b : delay timing.
944 944  
953 +
945 945  **Example:**
946 946  
947 947  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
... ... @@ -949,10 +949,11 @@
949 949  
950 950  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
951 951  
952 -(% style="color:blue" %)**0x09 02 aa bb cc   ** (%%)~/~/ same as AT+TRIG1=aa,0x(bb cc)
961 +**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
953 953  
954 954  
955 955  
965 +
956 956  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
957 957  
958 958  
... ... @@ -960,15 +960,16 @@
960 960  
961 961  * (% style="color:#037691" %)**AT Command**
962 962  
963 -(% style="color:blue" %)**AT+ACLIM**
973 +**AT+ACLIM**
964 964  
965 965  
966 966  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
967 967  
968 -(% style="color:blue" %)**0x AA 01 aa bb cc dd ee ff gg hh        ** (%%) ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
978 +**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
969 969  
970 970  
971 971  
982 +
972 972  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
973 973  
974 974  
... ... @@ -976,15 +976,16 @@
976 976  
977 977  * (% style="color:#037691" %)**AT Command**
978 978  
979 -(% style="color:blue" %)**AT+AVLIM    **(%%)** See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
990 +**AT+AVLIM  See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
980 980  
981 981  
982 982  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
983 983  
984 -(% style="color:blue" %)**0x AA 00 aa bb cc dd ee ff gg hh    ** (%%) ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
995 +**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
985 985  
986 986  
987 987  
999 +
988 988  ==== 3.4.2.11 Trigger – Set minimum interval ====
989 989  
990 990  
... ... @@ -992,12 +992,12 @@
992 992  
993 993  * (% style="color:#037691" %)**AT Command**
994 994  
995 -(% style="color:blue" %)**AT+ATDC=5        ** (%%)Device won't response the second trigger within 5 minute after the first trigger.
1007 +**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
996 996  
997 997  
998 998  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
999 999  
1000 -(% style="color:blue" %)**0x AC aa bb   **(%%) ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
1012 +**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
1001 1001  
1002 1002  (((
1003 1003  
... ... @@ -1007,6 +1007,7 @@
1007 1007  
1008 1008  
1009 1009  
1022 +
1010 1010  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
1011 1011  
1012 1012  
... ... @@ -1016,7 +1016,7 @@
1016 1016  
1017 1017  
1018 1018  * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
1019 -* (% style="color:blue" %)**0x02 aa bb cc     ** (%%)~/~/ Set DO1/DO2/DO3 output
1032 +* **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
1020 1020  
1021 1021  (((
1022 1022  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
... ... @@ -1038,6 +1038,7 @@
1038 1038  
1039 1039  
1040 1040  
1054 +
1041 1041  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
1042 1042  
1043 1043  
... ... @@ -1048,7 +1048,7 @@
1048 1048  
1049 1049  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1050 1050  
1051 -(% style="color:blue" %)**0xA9 aa bb cc     **(%%) ~/~/ Set DO1/DO2/DO3 output with time control
1065 +**0xA9 aa bb cc     **~/~/ Set DO1/DO2/DO3 output with time control
1052 1052  
1053 1053  
1054 1054  This is to control the digital output time of DO pin. Include four bytes:
... ... @@ -1104,6 +1104,7 @@
1104 1104  
1105 1105  
1106 1106  
1121 +
1107 1107  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1108 1108  
1109 1109  
... ... @@ -1114,7 +1114,7 @@
1114 1114  
1115 1115  * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1116 1116  
1117 -(% style="color:blue" %)**0x03 aa bb     ** (%%)~/~/ Set RO1/RO2 output
1132 +**0x03 aa bb     **~/~/ Set RO1/RO2 output
1118 1118  
1119 1119  
1120 1120  (((
... ... @@ -1144,7 +1144,7 @@
1144 1144  
1145 1145  * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1146 1146  
1147 -(% style="color:blue" %)**0x05 aa bb cc dd     ** (%%)~/~/ Set RO1/RO2 relay with time control
1162 +**0x05 aa bb cc dd     **~/~/ Set RO1/RO2 relay with time control
1148 1148  
1149 1149  
1150 1150  This is to control the relay output time of relay. Include four bytes:
... ... @@ -1195,33 +1195,39 @@
1195 1195  
1196 1196  * (% style="color:#037691" %)**AT Command:**
1197 1197  
1198 -(% style="color:blue" %)**AT+VOLMAX   ** (%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1213 +**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1199 1199  
1200 1200  
1201 1201  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
1202 1202  
1203 -(% style="color:blue" %)**0xA5 aa bb cc   ** (%%)~/~/ Same as AT+VOLMAX=(aa bb),cc
1218 +**0xA5 aa bb cc   **~/~/ Same as AT+VOLMAX=(aa bb),cc
1204 1204  
1205 1205  
1206 1206  
1222 +
1207 1207  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1208 1208  
1209 1209  
1210 1210  * (% style="color:#037691" %)**AT Command:**
1211 1211  
1212 -(% style="color:blue" %)**AT+SETCNT=aa,(bb cc dd ee) **
1228 +**AT+SETCNT=aa,(bb cc dd ee) **
1213 1213  
1214 -(% style="color:red" %)**aa:**(%%) 1: Set count1; 2: Set count2; 3: Set AV1 count
1230 +aa: 1: Set count1,
1215 1215  
1216 -(% style="color:red" %)**bb cc dd ee: **(%%)number to be set
1232 +2: Set count2,
1217 1217  
1234 +3: Set AV1 count
1218 1218  
1236 +Bb cc dd ee: number to be set
1237 +
1238 +
1219 1219  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**
1220 1220  
1221 -(% style="color:blue" %)**0x A8 aa bb cc dd ee     ** (%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1241 +**0x A8 aa bb cc dd ee     **~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1222 1222  
1223 1223  
1224 1224  
1245 +
1225 1225  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1226 1226  
1227 1227  
... ... @@ -1229,79 +1229,87 @@
1229 1229  
1230 1230  * (% style="color:#037691" %)**AT Command:**
1231 1231  
1232 -(% style="color:blue" %)**AT+CLRCOUNT **(%%) ~/~/ clear all counting
1253 +**AT+CLRCOUNT ** ~/~/ clear all counting
1233 1233  
1234 1234  
1235 1235  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
1236 1236  
1237 -(% style="color:blue" %)**0x A6 01    ** (%%)~/~/ clear all counting
1258 +**0x A6 01    ** ~/~/ clear all counting
1238 1238  
1239 1239  
1240 1240  
1262 +
1241 1241  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1242 1242  
1243 1243  
1244 1244  * (% style="color:#037691" %)**AT Command:**
1245 1245  
1246 -(% style="color:blue" %)**AT+COUTIME=60  **(%%)~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1268 +**AT+COUTIME=60  **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)
1247 1247  
1248 1248  
1249 1249  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):**
1250 1250  
1251 -(% style="color:blue" %)**0x A7 aa bb cc     ** (%%)~/~/ same as AT+COUTIME =aa bb cc,
1273 +**0x A7 aa bb cc     **~/~/ same as AT+COUTIME =aa bb cc,
1252 1252  
1253 1253  (((
1254 1254  range: aa bb cc:0 to 16777215,  (unit:second)
1255 -)))
1256 1256  
1257 1257  
1258 1258  
1280 +
1281 +)))
1282 +
1259 1259  ==== 3.4.2.20 Reset save DR DO state ====
1260 1260  
1261 1261  
1262 1262  * (% style="color:#037691" %)**AT Command:**
1263 1263  
1264 -(% style="color:blue" %)**AT+RODORET=1    **(%%)~/~/ RODO will close when the device joining the network. (default)
1288 +**AT+RODORET=1  **~/~/ RODO will close when the device joining the network. (default)
1265 1265  
1266 -(% style="color:blue" %)**AT+RODORET=0    **(%%)~/~/ After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1290 +**AT+RODORET=0  **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1267 1267  
1268 1268  
1269 1269  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
1270 1270  
1271 -(% style="color:blue" %)**0x AD aa      ** (%%)~/~/ same as AT+RODORET =aa
1295 +**0x AD aa      **~/~/ same as AT+RODORET =aa
1272 1272  
1297 +(((
1298 +
1273 1273  
1274 1274  
1301 +
1275 1275  ==== 3.4.2.21 Encrypted payload ====
1276 1276  
1277 1277  
1278 1278  * (% style="color:#037691" %)**AT Command:**
1279 1279  
1280 -(% style="color:blue" %)**AT+DECRYPT=1  ** (%%)~/~/ The payload is uploaded without encryption
1307 +**AT+DECRYPT=1  **~/~/ The payload is uploaded without encryption
1281 1281  
1282 -(% style="color:blue" %)**AT+DECRYPT=0    **(%%)~/~/  Encrypt when uploading payload (default)
1309 +**AT+DECRYPT=0  **~/~/Encrypt when uploading payload (default)
1283 1283  
1284 1284  
1285 1285  
1313 +
1286 1286  ==== 3.4.2.22 Get sensor value ====
1287 1287  
1288 1288  
1289 1289  * (% style="color:#037691" %)**AT Command:**
1290 1290  
1291 -(% style="color:blue" %)**AT+GETSENSORVALUE=0    **(%%)~/~/ The serial port gets the reading of the current sensor
1319 +**AT+GETSENSORVALUE=0  **~/~/ The serial port gets the reading of the current sensor
1292 1292  
1293 -(% style="color:blue" %)**AT+GETSENSORVALUE=1    **(%%)~/~/ The serial port gets the current sensor reading and uploads it.
1321 +**AT+GETSENSORVALUE=1  **~/~/The serial port gets the current sensor reading and uploads it.
1294 1294  
1295 1295  
1296 1296  
1325 +
1297 1297  ==== 3.4.2.23 Resets the downlink packet count ====
1298 1298  
1299 1299  
1300 1300  * (% style="color:#037691" %)**AT Command:**
1301 1301  
1302 -(% style="color:blue" %)**AT+DISFCNTCHECK=0   **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
1331 +**AT+DISFCNTCHECK=0  **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
1303 1303  
1304 -(% style="color:blue" %)**AT+DISFCNTCHECK=1   **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1333 +**AT+DISFCNTCHECK=1  **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1305 1305  
1306 1306  
1307 1307  
... ... @@ -1311,14 +1311,14 @@
1311 1311  
1312 1312  * (% style="color:#037691" %)**AT Command:**
1313 1313  
1314 -(% style="color:blue" %)**AT+DISMACANS=0**   (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
1343 + **AT+DISMACANS=0**  ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
1315 1315  
1316 -(% style="color:blue" %)**AT+DISMACANS=1**  (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.
1345 + **AT+DISMACANS=1**      ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.
1317 1317  
1318 1318  
1319 1319  * (% style="color:#037691" %)**Downlink Payload **(%%)**:**
1320 1320  
1321 -(% style="color:blue" %)**0x21 00 01 ** (%%) ~/~/ Set  the DISMACANS=1
1350 +**0x21 00 01 ** ~/~/ Set  the DISMACANS=1
1322 1322  
1323 1323  
1324 1324  
... ... @@ -1328,7 +1328,7 @@
1328 1328  
1329 1329  * (% style="color:#037691" %)**AT Command**(%%)**:**
1330 1330  
1331 -(% style="color:blue" %)**AT+RPL=5**   (%%) ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
1360 + **AT+RPL=5**  ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
1332 1332  
1333 1333  Example:**aa xx xx xx xx**         ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent.
1334 1334  
... ... @@ -1351,7 +1351,7 @@
1351 1351  * (((
1352 1352  (% style="color:#037691" %)**Downlink Payload**(%%)**:**
1353 1353  
1354 -(% style="color:blue" %)**26 01  ** (%%) ~/~/  Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1383 +**26 01  ** ~/~/  Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1355 1355  
1356 1356  
1357 1357  )))
... ... @@ -1361,6 +1361,8 @@
1361 1361  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1362 1362  
1363 1363  
1393 +
1394 +)))
1364 1364  
1365 1365  == 3.5 Integrate with Mydevice ==
1366 1366  
... ... @@ -1960,7 +1960,7 @@
1960 1960  
1961 1961  
1962 1962  (((
1963 -(% style="color:blue" %)**If sensor JOINED:**
1994 +(% style="color:blue" %)If sensor JOINED:
1964 1964  
1965 1965  (% style="background-color:#dcdcdc" %)**AT+CLASS=A
1966 1966  ATZ**
... ... @@ -2045,6 +2045,7 @@
2045 2045  (((
2046 2046  Assume we have a LG02 working in the frequency 868400000 now , below is the step.
2047 2047  
2079 +
2048 2048  
2049 2049  )))
2050 2050  )))
... ... @@ -2197,9 +2197,6 @@
2197 2197  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2198 2198  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2199 2199  
2200 -
2201 -
2202 -
2203 2203  = 8. Packing Info =
2204 2204  
2205 2205  
... ... @@ -2217,9 +2217,6 @@
2217 2217  * Package Size / pcs : 14.5 x 8 x 5 cm
2218 2218  * Weight / pcs : 170g
2219 2219  
2220 -
2221 -
2222 -
2223 2223  = 9. Support =
2224 2224  
2225 2225  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0