Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,16 +15,13 @@ 15 15 16 16 = 1.Introduction = 17 17 18 - 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 22 23 23 24 -((( 25 25 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 26 26 ))) 27 -))) 28 28 29 29 ((( 30 30 The LT I/O Controllers allows the user to send data and reach extremely long ranges. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. It targets professional wireless sensor network applications such as irrigation systems, smart metering, smart cities, smartphone detection, building automation, and so on. ... ... @@ -39,7 +39,7 @@ 39 39 ))) 40 40 41 41 ((( 42 -1) If user 's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.39 +1) If user’s area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 43 43 ))) 44 44 45 45 ((( ... ... @@ -60,7 +60,7 @@ 60 60 ((( 61 61 62 62 63 - (% style="color:#037691" %)**Hardware System:**60 +**Hardware System:** 64 64 ))) 65 65 66 66 * ((( ... ... @@ -85,7 +85,7 @@ 85 85 ((( 86 86 87 87 88 - (% style="color:#037691" %)**Interface for Model: LT22222-L:**85 +**Interface for Model: LT22222-L:** 89 89 ))) 90 90 91 91 * ((( ... ... @@ -110,7 +110,7 @@ 110 110 ((( 111 111 112 112 113 - (% style="color:#037691" %)**LoRa Spec:**110 +**LoRa Spec:** 114 114 ))) 115 115 116 116 * ((( ... ... @@ -180,7 +180,7 @@ 180 180 181 181 * LoRaWAN Class A & Class C protocol 182 182 * Optional Customized LoRa Protocol 183 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 /MA869180 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 184 184 * AT Commands to change parameters 185 185 * Remote configure parameters via LoRa Downlink 186 186 * Firmware upgradable via program port ... ... @@ -218,18 +218,13 @@ 218 218 219 219 220 220 221 - 222 222 = 2. Power ON Device = 223 223 224 224 225 -((( 226 226 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 227 -))) 228 228 229 229 ((( 230 230 PWR will on when device is properly powered. 231 - 232 - 233 233 ))) 234 234 235 235 [[image:1653297104069-180.png]] ... ... @@ -238,7 +238,6 @@ 238 238 239 239 = 3. Operation Mode = 240 240 241 - 242 242 == 3.1 How it works? == 243 243 244 244 ... ... @@ -283,12 +283,12 @@ 283 283 284 284 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 285 285 286 - **Add APP EUI in the application.**277 +Add APP EUI in the application. 287 287 288 288 [[image:1653297955910-247.png||height="321" width="716"]] 289 289 290 290 291 - **Add APP KEY and DEV EUI**282 +Add APP KEY and DEV EUI 292 292 293 293 [[image:1653298023685-319.png]] 294 294 ... ... @@ -296,8 +296,6 @@ 296 296 297 297 ((( 298 298 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 299 - 300 - 301 301 ))) 302 302 303 303 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -322,9 +322,7 @@ 322 322 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 323 323 324 324 325 -((( 326 326 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 327 -))) 328 328 329 329 [[image:image-20220523174024-3.png]] 330 330 ... ... @@ -340,7 +340,7 @@ 340 340 * DI is for digital input. DIx=1: high or float, DIx=0: low. 341 341 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 342 342 343 -(% style="color:red" %) **Note: DI3 and DO3 bit are not valid for LT-22222-L**330 +(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L 344 344 345 345 For example if payload is: [[image:image-20220523175847-2.png]] 346 346 ... ... @@ -360,6 +360,7 @@ 360 360 * [1] RO1 relay channel is close and the RO1 LED is ON. 361 361 * [0] RO2 relay channel is open and RO2 LED is OFF; 362 362 350 + 363 363 **LT22222-L:** 364 364 365 365 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -381,9 +381,7 @@ 381 381 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 382 382 383 383 384 -((( 385 385 **For LT-22222-L**: this mode the **DI1 and DI2** are used as counting pins. 386 -))) 387 387 388 388 ((( 389 389 Total : 11 bytes payload ... ... @@ -403,7 +403,7 @@ 403 403 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 404 404 405 405 ((( 406 -(% style="color:red" %) **Note: DO3 bit is not valid for LT-22222-L.**392 +(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 407 407 ))) 408 408 409 409 ((( ... ... @@ -415,22 +415,16 @@ 415 415 (% class="box infomessage" %) 416 416 ((( 417 417 ((( 418 -((( 419 419 **AT+MOD=2** 420 -))) 421 421 422 -((( 423 423 **ATZ** 424 424 ))) 425 425 ))) 426 -))) 427 427 428 428 ((( 429 429 430 430 431 431 (% style="color:#4f81bd" %)**AT Commands for counting:** 432 - 433 - 434 434 ))) 435 435 436 436 ((( ... ... @@ -472,7 +472,7 @@ 472 472 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 473 473 474 474 ((( 475 -(% style="color:red" %) **Note: DO3 is not valid for LT-22222-L.**455 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 476 476 ))) 477 477 478 478 ... ... @@ -483,15 +483,11 @@ 483 483 (% class="box infomessage" %) 484 484 ((( 485 485 ((( 486 -((( 487 487 **AT+MOD=3** 488 -))) 489 489 490 -((( 491 491 **ATZ** 492 492 ))) 493 493 ))) 494 -))) 495 495 496 496 ((( 497 497 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -502,13 +502,9 @@ 502 502 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 503 503 504 504 505 -((( 506 506 **LT22222-L**: This mode the DI1 is used as a counting pin. 507 -))) 508 508 509 -((( 510 510 The AVI1 is also used for counting. AVI1 is used to monitor the voltage. It will check the voltage **every 60s**, if voltage is higher or lower than VOLMAX mV, the AVI1 Counting increase 1, so AVI1 counting can be used to measure a machine working hour. 511 -))) 512 512 513 513 [[image:image-20220523181903-8.png]] 514 514 ... ... @@ -524,7 +524,7 @@ 524 524 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 525 525 526 526 ((( 527 -(% style="color:red" %) **Note: DO3 is not valid for LT-22222-L.**499 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 528 528 ))) 529 529 530 530 ((( ... ... @@ -536,17 +536,14 @@ 536 536 (% class="box infomessage" %) 537 537 ((( 538 538 ((( 539 -((( 540 540 **AT+MOD=4** 541 -))) 542 542 543 -((( 544 544 **ATZ** 545 545 ))) 546 546 ))) 547 -))) 548 548 549 549 518 + 550 550 ((( 551 551 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 552 552 ))) ... ... @@ -588,7 +588,7 @@ 588 588 ))) 589 589 590 590 ((( 591 -(% style="color:red" %) **Note: DO3 is not valid for LT-22222-L.**560 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 592 592 ))) 593 593 594 594 ((( ... ... @@ -600,15 +600,11 @@ 600 600 (% class="box infomessage" %) 601 601 ((( 602 602 ((( 603 -((( 604 604 **AT+MOD=5** 605 -))) 606 606 607 -((( 608 608 **ATZ** 609 609 ))) 610 610 ))) 611 -))) 612 612 613 613 ((( 614 614 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. ... ... @@ -638,7 +638,6 @@ 638 638 639 639 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 640 640 641 - 642 642 **Example:** 643 643 644 644 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) ... ... @@ -651,7 +651,6 @@ 651 651 652 652 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 653 653 654 - 655 655 **Example:** 656 656 657 657 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) ... ... @@ -670,7 +670,6 @@ 670 670 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 671 671 672 672 673 - 674 674 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 675 675 676 676 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -719,7 +719,6 @@ 719 719 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 720 720 721 721 722 - 723 723 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 724 724 725 725 [[image:image-20220524090249-3.png]] ... ... @@ -731,7 +731,6 @@ 731 731 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 732 732 733 733 734 - 735 735 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 736 736 737 737 [[image:image-20220524090456-4.png]] ... ... @@ -745,7 +745,6 @@ 745 745 00000101: Means both DI1 and DI2 trigger are enabled. 746 746 747 747 748 - 749 749 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 750 750 751 751 Downlink command to poll MOD6 status: ... ... @@ -761,36 +761,32 @@ 761 761 ((( 762 762 763 763 764 -**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 723 +**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 724 + 725 + 765 765 ))) 766 766 767 767 768 - 769 769 == 3.4 Configure LT via AT or Downlink == 770 770 771 771 772 -((( 773 773 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 774 -))) 775 775 776 776 ((( 777 -((( 778 778 There are two kinds of Commands: 779 779 ))) 780 -))) 781 781 782 -* (% style="color:b lue" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]738 +* (% style="color:#4f81bd" %)**Common Commands**(%%): They should be available for each sensor, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 783 783 784 -* (% style="color:b lue" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below:740 +* (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 785 785 786 786 787 787 744 + 788 788 === 3.4.1 Common Commands === 789 789 790 790 791 -((( 792 792 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 793 -))) 794 794 795 795 796 796 ... ... @@ -804,7 +804,7 @@ 804 804 805 805 * (% style="color:#037691" %)**AT Command:** 806 806 807 -** (% style="color:blue" %)AT+TDC=N **762 +**AT+TDC=N ** 808 808 809 809 810 810 **Example: **AT+TDC=30000. Means set interval to 30 seconds ... ... @@ -812,7 +812,7 @@ 812 812 813 813 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 814 814 815 -** (% style="color:blue" %)0x01 aa bb cc(%%)~/~/ Same as AT+TDC=0x(aa bb cc)**770 +**0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 816 816 817 817 818 818 ... ... @@ -824,7 +824,7 @@ 824 824 825 825 * (% style="color:#037691" %)**AT Command:** 826 826 827 -** (% style="color:blue" %)AT+MOD=N **782 +**AT+MOD=N ** 828 828 829 829 830 830 **Example**: AT+MOD=2. Set work mode to Double DI counting mode ... ... @@ -832,7 +832,7 @@ 832 832 833 833 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 834 834 835 -** (% style="color:blue" %)0x0A aa(%%)** ~/~/ Same as AT+MOD=aa790 +**0x0A aa ** ~/~/ Same as AT+MOD=aa 836 836 837 837 838 838 ... ... @@ -847,9 +847,8 @@ 847 847 848 848 * (% style="color:#037691" %)**Downlink Payload (prefix 0x08):** 849 849 850 -** (% style="color:blue" %)0x08 FF(%%)**~/~/ Poll an uplink805 +**0x08 FF **~/~/ Poll an uplink 851 851 852 - 853 853 **Example**: 0x08FF, ask device to send an Uplink 854 854 855 855 ... ... @@ -862,16 +862,16 @@ 862 862 863 863 * (% style="color:#037691" %)**AT Command:** 864 864 865 -** (% style="color:blue" %)AT+ADDMOD6=1 or 0**819 +**AT+ADDMOD6=1 or 0** 866 866 867 - **(% style="color:red" %)1:**Enable Trigger Mode821 +1: Enable Trigger Mode 868 868 869 - **(% style="color:red" %)0:**Disable Trigger Mode823 +0: Disable Trigger Mode 870 870 871 871 872 872 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):** 873 873 874 -** (% style="color:blue" %)0x0A 06 aa **(%%)828 +**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 875 875 876 876 877 877 ... ... @@ -888,7 +888,7 @@ 888 888 889 889 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 890 890 891 -** (% style="color:blue" %)0xAB 06 **(%%)~/~/ Poll trigger settings, device will uplink trigger settings once receive this command845 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 892 892 893 893 894 894 ... ... @@ -909,7 +909,7 @@ 909 909 910 910 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):** 911 911 912 -** (% style="color:blue" %)0xAA 02 aa bb **(%%)~/~/ Same as AT+DTRI=aa,bb866 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 913 913 914 914 915 915 ... ... @@ -921,11 +921,11 @@ 921 921 922 922 * (% style="color:#037691" %)**AT Command:** 923 923 924 -** (% style="color:blue" %)AT+TRIG1=a,b**878 +**AT+TRIG1=a,b** 925 925 926 - **(% style="color:red" %)a :**(%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).880 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 927 927 928 - **(% style="color:red" %)b :**(%%)delay timing.882 +b : delay timing. 929 929 930 930 931 931 **Example:** ... ... @@ -934,7 +934,7 @@ 934 934 935 935 936 936 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 937 -* ** (% style="color:blue" %)0x09 01 aa bb cc **(%%)~/~/ same as AT+TRIG1=aa,0x(bb cc)891 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 938 938 939 939 940 940 ... ... @@ -946,12 +946,12 @@ 946 946 947 947 * (% style="color:#037691" %)**AT Command:** 948 948 949 -** (% style="color:blue" %)AT+TRIG2=a,b**903 +**AT+TRIG2=a,b** 950 950 951 951 952 - **(% style="color:red" %)a :**(%%)Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).906 +a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 953 953 954 - **(% style="color:red" %)b :**(%%)delay timing.908 +b : delay timing. 955 955 956 956 957 957 **Example:** ... ... @@ -961,7 +961,7 @@ 961 961 962 962 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 963 963 964 -** (% style="color:blue" %)0x09 02 aa bb cc **(%%)~/~/ same as AT+TRIG1=aa,0x(bb cc)918 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 965 965 966 966 967 967 ... ... @@ -973,12 +973,12 @@ 973 973 974 974 * (% style="color:#037691" %)**AT Command** 975 975 976 -** (% style="color:blue" %)AT+ACLIM**930 +**AT+ACLIM** 977 977 978 978 979 979 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 980 980 981 -** (% style="color:blue" %)0x AA 01 aa bb cc dd ee ff gg hh **(%%)~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]935 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 982 982 983 983 984 984 ... ... @@ -990,12 +990,12 @@ 990 990 991 991 * (% style="color:#037691" %)**AT Command** 992 992 993 -** (% style="color:blue" %)AT+AVLIM(%%)See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**947 +**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 994 994 995 995 996 996 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 997 997 998 -** (% style="color:blue" %)0x AA 00 aa bb cc dd ee ff gg hh **(%%)~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]952 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 999 999 1000 1000 1001 1001 ... ... @@ -1007,17 +1007,17 @@ 1007 1007 1008 1008 * (% style="color:#037691" %)**AT Command** 1009 1009 1010 -** (% style="color:blue" %)AT+ATDC=5 **(%%)Device won't response the second trigger within 5 minute after the first trigger.964 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 1011 1011 1012 1012 1013 1013 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 1014 1014 1015 -** (% style="color:blue" %)0x AC aa bb **(%%)~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)969 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 1016 1016 1017 1017 ((( 1018 1018 1019 1019 1020 -(% style="color:red" %) **Note: ATDC setting must be more than 5min**974 +(% style="color:red" %)Note: ATDC setting must be more than 5min 1021 1021 ))) 1022 1022 1023 1023 ... ... @@ -1032,7 +1032,7 @@ 1032 1032 1033 1033 1034 1034 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 1035 -* ** (% style="color:blue" %)0x02 aa bb cc **(%%)~/~/ Set DO1/DO2/DO3 output989 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1036 1036 1037 1037 ((( 1038 1038 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. ... ... @@ -1045,11 +1045,11 @@ 1045 1045 [[image:image-20220524092754-5.png]] 1046 1046 1047 1047 ((( 1048 -(% style="color:red" %) **Note: For LT-22222-L, there is no DO3, the last byte can use any value.**1002 +(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value. 1049 1049 ))) 1050 1050 1051 1051 ((( 1052 -(% style="color:red" %) **Device will upload a packet if downlink code executes successfully.**1006 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1053 1053 ))) 1054 1054 1055 1055 ... ... @@ -1065,7 +1065,7 @@ 1065 1065 1066 1066 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1067 1067 1068 -** (% style="color:blue" %)0xA9 aa bb cc **(%%)~/~/ Set DO1/DO2/DO3 output with time control1022 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1069 1069 1070 1070 1071 1071 This is to control the digital output time of DO pin. Include four bytes: ... ... @@ -1094,11 +1094,11 @@ 1094 1094 [[image:image-20220524093351-8.png]] 1095 1095 1096 1096 1097 -(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and NinthByte**:1051 +(% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1098 1098 1099 1099 Latching time. Unit: ms 1100 1100 1101 - (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**1055 +Device will upload a packet if downlink code executes successfully. 1102 1102 1103 1103 1104 1104 **Example payload:** ... ... @@ -1132,7 +1132,7 @@ 1132 1132 1133 1133 * (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1134 1134 1135 -** (% style="color:blue" %)0x03 aa bb **(%%)~/~/ Set RO1/RO2 output1089 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1136 1136 1137 1137 1138 1138 ((( ... ... @@ -1147,7 +1147,7 @@ 1147 1147 [[image:image-20220524093724-9.png]] 1148 1148 ))) 1149 1149 1150 - (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**1104 +Device will upload a packet if downlink code executes successfully. 1151 1151 1152 1152 1153 1153 ... ... @@ -1162,7 +1162,7 @@ 1162 1162 1163 1163 * (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1164 1164 1165 -** (% style="color:blue" %)0x05 aa bb cc dd **(%%)~/~/ Set RO1/RO2 relay with time control1119 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1166 1166 1167 1167 1168 1168 This is to control the relay output time of relay. Include four bytes: ... ... @@ -1178,12 +1178,12 @@ 1178 1178 1179 1179 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1180 1180 1181 -[[image:image-2022 1008095908-1.png||height="364" width="564"]]1135 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1182 1182 1183 1183 1184 -(% style="color:#4f81bd" %)**Fourth/Fifth /Sixth/SeventhBytes(cc)**(%%): Latching time. Unit: ms1138 +(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 1185 1185 1186 - (% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**1140 +Device will upload a packet if downlink code executes successfully. 1187 1187 1188 1188 1189 1189 **Example payload:** ... ... @@ -1206,6 +1206,7 @@ 1206 1206 1207 1207 1208 1208 1163 + 1209 1209 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1210 1210 1211 1211 ... ... @@ -1213,12 +1213,12 @@ 1213 1213 1214 1214 * (% style="color:#037691" %)**AT Command:** 1215 1215 1216 -** (% style="color:blue" %)AT+VOLMAX **(%%)~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]1171 +**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1217 1217 1218 1218 1219 1219 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1220 1220 1221 -** (% style="color:blue" %)0xA5 aa bb cc **(%%)~/~/ Same as AT+VOLMAX=(aa bb),cc1176 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1222 1222 1223 1223 1224 1224 ... ... @@ -1228,16 +1228,20 @@ 1228 1228 1229 1229 * (% style="color:#037691" %)**AT Command:** 1230 1230 1231 -** (% style="color:blue" %)AT+SETCNT=aa,(bb cc dd ee) **1186 +**AT+SETCNT=aa,(bb cc dd ee) ** 1232 1232 1233 - **(% style="color:red" %)aa:**(%%)1: Set count1; 2: Set count2; 3: Set AV1 count1188 +aa: 1: Set count1, 1234 1234 1235 - **(% style="color:red"%)bb cc ddee:**(%%)numberto be set1190 +2: Set count2, 1236 1236 1192 +3: Set AV1 count 1237 1237 1194 +Bb cc dd ee: number to be set 1195 + 1196 + 1238 1238 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1239 1239 1240 -** (% style="color:blue" %)0x A8 aa bb cc dd ee **(%%)~/~/ same as AT+SETCNT=aa,(bb cc dd ee)1199 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1241 1241 1242 1242 1243 1243 ... ... @@ -1249,12 +1249,12 @@ 1249 1249 1250 1250 * (% style="color:#037691" %)**AT Command:** 1251 1251 1252 -** (% style="color:blue" %)AT+CLRCOUNT **(%%)~/~/ clear all counting1211 +**AT+CLRCOUNT ** ~/~/ clear all counting 1253 1253 1254 1254 1255 1255 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1256 1256 1257 -** (% style="color:blue" %)0x A6 01 **(%%)~/~/ clear all counting1216 +**0x A6 01 ** ~/~/ clear all counting 1258 1258 1259 1259 1260 1260 ... ... @@ -1264,131 +1264,21 @@ 1264 1264 1265 1265 * (% style="color:#037691" %)**AT Command:** 1266 1266 1267 -** (% style="color:blue" %)AT+COUTIME=60 **(%%)~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)1226 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1268 1268 1269 1269 1270 1270 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1271 1271 1272 -** (% style="color:blue" %)0x A7 aa bb cc **(%%)~/~/ same as AT+COUTIME =aa bb cc,1231 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1273 1273 1274 1274 ((( 1275 1275 range: aa bb cc:0 to 16777215, (unit:second) 1276 -))) 1277 1277 1278 - 1279 - 1280 - 1281 -==== 3.4.2.20 Reset save DR DO state ==== 1282 - 1283 - 1284 -* (% style="color:#037691" %)**AT Command:** 1285 - 1286 -**(% style="color:blue" %)AT+RODORET=1 **(%%)~/~/ RODO will close when the device joining the network. (default) 1287 - 1288 -**(% style="color:blue" %)AT+RODORET=0 **(%%)~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1289 - 1290 - 1291 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1292 - 1293 -**(% style="color:blue" %)0x AD aa ** (%%)~/~/ same as AT+RODORET =aa 1294 - 1295 1295 1296 - 1297 - 1298 -==== 3.4.2.21 Encrypted payload ==== 1299 - 1300 - 1301 -* (% style="color:#037691" %)**AT Command:** 1302 - 1303 -**(% style="color:blue" %)AT+DECRYPT=1 ** (%%)~/~/ The payload is uploaded without encryption 1304 - 1305 -**(% style="color:blue" %)AT+DECRYPT=0 **(%%)~/~/Encrypt when uploading payload (default) 1306 - 1307 - 1308 - 1309 - 1310 -==== 3.4.2.22 Get sensor value ==== 1311 - 1312 - 1313 -* (% style="color:#037691" %)**AT Command:** 1314 - 1315 -**(% style="color:blue" %)AT+GETSENSORVALUE=0 **(%%)~/~/ The serial port gets the reading of the current sensor 1316 - 1317 -**(% style="color:blue" %)AT+GETSENSORVALUE=1 **(%%)~/~/The serial port gets the current sensor reading and uploads it. 1318 - 1319 - 1320 - 1321 - 1322 -==== 3.4.2.23 Resets the downlink packet count ==== 1323 - 1324 - 1325 -* (% style="color:#037691" %)**AT Command:** 1326 - 1327 -**(% style="color:blue" %)AT+DISFCNTCHECK=0 **(%%)~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1328 - 1329 -**(% style="color:blue" %)AT+DISFCNTCHECK=1 **(%%)~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1330 - 1331 - 1332 - 1333 - 1334 -==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1335 - 1336 - 1337 -* (% style="color:#037691" %)**AT Command:** 1338 - 1339 -**(% style="color:blue" %)AT+DISMACANS=0** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1340 - 1341 -**(% style="color:blue" %)AT+DISMACANS=1** (%%) ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1342 - 1343 - 1344 -* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1345 - 1346 -**(% style="color:blue" %)0x21 00 01 ** (%%) ~/~/ Set the DISMACANS=1 1347 - 1348 - 1349 - 1350 - 1351 -==== 3.4.2.25 Copy downlink to uplink ==== 1352 - 1353 - 1354 -* (% style="color:#037691" %)**AT Command**(%%)**:** 1355 - 1356 -**(% style="color:blue" %)AT+RPL=5** (%%) ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1357 - 1358 -Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1359 - 1360 - 1361 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1362 - 1363 -For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1364 - 1365 - 1366 - 1367 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1368 - 1369 -For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1370 - 1371 - 1372 - 1373 -==== 3.4.2.26 Query version number and frequency band 、TDC ==== 1374 - 1375 - 1376 -* ((( 1377 -(% style="color:#037691" %)**Downlink Payload**(%%)**:** 1378 - 1379 -**(% style="color:blue" %)26 01 ** (%%) ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1380 - 1381 - 1382 1382 ))) 1383 1383 1384 -**Example:** 1385 1385 1386 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1387 1387 1388 - 1389 - 1390 -))) 1391 - 1392 1392 == 3.5 Integrate with Mydevice == 1393 1393 1394 1394 ... ... @@ -1487,10 +1487,10 @@ 1487 1487 ))) 1488 1488 1489 1489 * ((( 1490 -Connect sensor 's output to DI1-1339 +Connect sensor’s output to DI1- 1491 1491 ))) 1492 1492 * ((( 1493 -Connect sensor 's VCC to DI1+.1342 +Connect sensor’s VCC to DI1+. 1494 1494 ))) 1495 1495 1496 1496 ((( ... ... @@ -1498,11 +1498,11 @@ 1498 1498 ))) 1499 1499 1500 1500 ((( 1501 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1 **+**/ 1K.**1350 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.** 1502 1502 ))) 1503 1503 1504 1504 ((( 1505 -If **DI1+**=**12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.1354 +If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1506 1506 ))) 1507 1507 1508 1508 ((( ... ... @@ -1520,10 +1520,10 @@ 1520 1520 ))) 1521 1521 1522 1522 * ((( 1523 -Connect sensor 's output to DI1+1372 +Connect sensor’s output to DI1+ 1524 1524 ))) 1525 1525 * ((( 1526 -Connect sensor 's GND DI1-.1375 +Connect sensor’s GND DI1-. 1527 1527 ))) 1528 1528 1529 1529 ((( ... ... @@ -1553,10 +1553,10 @@ 1553 1553 ))) 1554 1554 1555 1555 * ((( 1556 -Connect sensor 's output to DI1+ with a serial 50K resistor1405 +Connect sensor’s output to DI1+ with a serial 50K resistor 1557 1557 ))) 1558 1558 * ((( 1559 -Connect sensor 's GND DI1-.1408 +Connect sensor’s GND DI1-. 1560 1560 ))) 1561 1561 1562 1562 ((( ... ... @@ -1597,13 +1597,13 @@ 1597 1597 We take the wind speed sensor as an example for reference only. 1598 1598 1599 1599 1600 - (% style="color:blue" %)**Specifications of the wind speed sensor:**1449 +**Specifications of the wind speed sensor:** 1601 1601 1602 - **Red: 12~~24v**1451 +Red: 12~~24v 1603 1603 1604 - **Yellow: 4~~20mA**1453 +Yellow: 4~~20mA 1605 1605 1606 - **Black: GND**1455 +Black: GND 1607 1607 1608 1608 1609 1609 **Connection diagram:** ... ... @@ -1623,7 +1623,6 @@ 1623 1623 1624 1624 [[image:image-20220524100215-9.png]] 1625 1625 1626 - 1627 1627 [[image:image-20220524100215-10.png||height="382" width="723"]] 1628 1628 1629 1629 ... ... @@ -1641,14 +1641,8 @@ 1641 1641 == 4.1 Access AT Command == 1642 1642 1643 1643 1644 -((( 1645 1645 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1646 -))) 1647 1647 1648 -((( 1649 - 1650 -))) 1651 - 1652 1652 [[image:1653358238933-385.png]] 1653 1653 1654 1654 ... ... @@ -1676,7 +1676,7 @@ 1676 1676 ))) 1677 1677 1678 1678 ((( 1679 -AT+<CMD>=? : 1521 +AT+<CMD>=? : Get the value 1680 1680 ))) 1681 1681 1682 1682 ((( ... ... @@ -1704,11 +1704,11 @@ 1704 1704 ))) 1705 1705 1706 1706 ((( 1707 -AT+APPSKEY: 1549 +AT+APPSKEY: Get or Set the Application Session Key 1708 1708 ))) 1709 1709 1710 1710 ((( 1711 -AT+APPEUI: 1553 +AT+APPEUI: Get or Set the Application EUI 1712 1712 ))) 1713 1713 1714 1714 ((( ... ... @@ -1720,7 +1720,7 @@ 1720 1720 ))) 1721 1721 1722 1722 ((( 1723 -AT+DR: 1565 +AT+DR: Get or Set the Data Rate. (0-7 corresponding to DR_X) 1724 1724 ))) 1725 1725 1726 1726 ((( ... ... @@ -1756,7 +1756,7 @@ 1756 1756 ))) 1757 1757 1758 1758 ((( 1759 -AT+NJM: 1601 +AT+NJM: Get or Set the Network Join Mode. (0: ABP, 1: OTAA) 1760 1760 ))) 1761 1761 1762 1762 ((( ... ... @@ -1800,7 +1800,7 @@ 1800 1800 ))) 1801 1801 1802 1802 ((( 1803 -AT+VER: 1645 +AT+VER: Get current image version and Frequency Band 1804 1804 ))) 1805 1805 1806 1806 ((( ... ... @@ -1808,7 +1808,7 @@ 1808 1808 ))) 1809 1809 1810 1810 ((( 1811 -AT+CFS: 1653 +AT+CFS: Get confirmation status of the last AT+SEND (0-1) 1812 1812 ))) 1813 1813 1814 1814 ((( ... ... @@ -1857,42 +1857,40 @@ 1857 1857 ((( 1858 1858 1859 1859 1860 -((( 1861 -(% style="color:blue" %)**If device has not joined network yet:** 1702 +**If device has not joined network yet:** 1862 1862 ))) 1863 -))) 1864 1864 1865 1865 ((( 1866 -(% style="background-color:#dcdcdc" %) **123456**1706 +(% style="background-color:#dcdcdc" %)123456 1867 1867 ))) 1868 1868 1869 1869 ((( 1870 -(% style="background-color:#dcdcdc" %) **AT+FDR**1710 +(% style="background-color:#dcdcdc" %)AT+FDR 1871 1871 ))) 1872 1872 1873 1873 ((( 1874 -(% style="background-color:#dcdcdc" %) **123456**1714 +(% style="background-color:#dcdcdc" %)123456 1875 1875 ))) 1876 1876 1877 1877 ((( 1878 -(% style="background-color:#dcdcdc" %) **AT+NJM=0**1718 +(% style="background-color:#dcdcdc" %)AT+NJM=0 1879 1879 ))) 1880 1880 1881 1881 ((( 1882 -(% style="background-color:#dcdcdc" %) **ATZ**1722 +(% style="background-color:#dcdcdc" %)ATZ 1883 1883 ))) 1884 1884 1885 1885 1886 1886 ((( 1887 - (% style="color:blue" %)**If device already joined network:**1727 +**If device already joined network:** 1888 1888 ))) 1889 1889 1890 1890 ((( 1891 -(% style="background-color:#dcdcdc" %) **AT+NJM=0**1731 +(% style="background-color:#dcdcdc" %)AT+NJM=0 1892 1892 ))) 1893 1893 1894 1894 ((( 1895 -(% style="background-color:#dcdcdc" %) **ATZ**1735 +(% style="background-color:#dcdcdc" %)ATZ 1896 1896 ))) 1897 1897 1898 1898 ... ... @@ -1902,57 +1902,55 @@ 1902 1902 ((( 1903 1903 1904 1904 1905 -((( 1906 -(% style="background-color:#dcdcdc" %)**123456**(%%) ~/~/ Enter Password to have AT access. 1745 +(% style="background-color:#dcdcdc" %)123456(%%) Enter Password to have AT access. 1907 1907 ))) 1908 -))) 1909 1909 1910 1910 ((( 1911 -(% style="background-color:#dcdcdc" %) **AT+FDR**(%%)~/~/Reset Parameters to Factory Default, Keys Reserve1749 +(% style="background-color:#dcdcdc" %) AT+FDR(%%) Reset Parameters to Factory Default, Keys Reserve 1912 1912 ))) 1913 1913 1914 1914 ((( 1915 -(% style="background-color:#dcdcdc" %) **123456**(%%)~/~/Enter Password to have AT access.1753 +(% style="background-color:#dcdcdc" %) 123456(%%) Enter Password to have AT access. 1916 1916 ))) 1917 1917 1918 1918 ((( 1919 -(% style="background-color:#dcdcdc" %) **AT+CLASS=C**(%%)~/~/Set to work in CLASS C1757 +(% style="background-color:#dcdcdc" %) AT+CLASS=C(%%) Set to work in CLASS C 1920 1920 ))) 1921 1921 1922 1922 ((( 1923 -(% style="background-color:#dcdcdc" %) **AT+NJM=0**(%%)~/~/Set to ABP mode1761 +(% style="background-color:#dcdcdc" %) AT+NJM=0(%%) Set to ABP mode 1924 1924 ))) 1925 1925 1926 1926 ((( 1927 -(% style="background-color:#dcdcdc" %) **AT+ADR=0**(%%)~/~/Set the Adaptive Data Rate Off1765 +(% style="background-color:#dcdcdc" %) AT+ADR=0(%%) Set the Adaptive Data Rate Off 1928 1928 ))) 1929 1929 1930 1930 ((( 1931 -(% style="background-color:#dcdcdc" %) **AT+DR=5**(%%)~/~/Set Data Rate1769 +(% style="background-color:#dcdcdc" %) AT+DR=5(%%) Set Data Rate 1932 1932 ))) 1933 1933 1934 1934 ((( 1935 -(% style="background-color:#dcdcdc" %) **AT+TDC=60000**(%%)~/~/Set transmit interval to 60 seconds1773 +(% style="background-color:#dcdcdc" %) AT+TDC=60000(%%) Set transmit interval to 60 seconds 1936 1936 ))) 1937 1937 1938 1938 ((( 1939 -(% style="background-color:#dcdcdc" %) **AT+CHS=868400000**(%%)~/~/Set transmit frequency to 868.4Mhz1777 +(% style="background-color:#dcdcdc" %) AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1940 1940 ))) 1941 1941 1942 1942 ((( 1943 -(% style="background-color:#dcdcdc" %) **AT+RX2FQ=868400000**(%%)~/~/Set RX2Frequency to 868.4Mhz (according to the result from server)1781 +(% style="background-color:#dcdcdc" %) AT+RX2FQ=868400000(%%) Set RX2Frequency to 868.4Mhz (according to the result from server) 1944 1944 ))) 1945 1945 1946 1946 ((( 1947 -(% style="background-color:#dcdcdc" %) **AT+RX2DR=5**(%%)****~/~/Set RX2DR to match the downlink DR from server. see below1785 +(% style="background-color:#dcdcdc" %) AT+RX2DR=5(%%) Set RX2DR to match the downlink DR from server. see below 1948 1948 ))) 1949 1949 1950 1950 ((( 1951 -(% style="background-color:#dcdcdc" %) **AT+DADDR=26 01 1A F1**(%%)~/~/Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal.1789 +(% style="background-color:#dcdcdc" %) AT+DADDR=26 01 1A F1 (%%) Set Device Address to 26 01 1A F1, this ID can be found in the LoRa Server portal. 1952 1952 ))) 1953 1953 1954 1954 ((( 1955 -(% style="background-color:#dcdcdc" %) **ATZ**(%%)~/~/Reset MCU1793 +(% style="background-color:#dcdcdc" %) ATZ (%%) Reset MCU 1956 1956 1957 1957 1958 1958 ))) ... ... @@ -1962,16 +1962,10 @@ 1962 1962 ))) 1963 1963 1964 1964 ((( 1965 -**~1. Make sure the device is set to ABP mode in the IoT Server.** 1966 - 1967 -**2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.** 1968 - 1969 -**3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php? 1970 -dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.** 1971 - 1972 -**4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5** 1973 - 1974 - 1803 +(% style="color:red" %)1. Make sure the device is set to ABP mode in the IoT Server. 1804 +2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1805 +3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1806 +4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1975 1975 ))) 1976 1976 1977 1977 ((( ... ... @@ -1986,15 +1986,12 @@ 1986 1986 === 4.2.3 Change to Class A === 1987 1987 1988 1988 1989 -((( 1990 -(% style="color:blue" %)If sensor JOINED: 1821 +If sensor JOINED 1822 +(% style="background-color:#dcdcdc" %)AT+CLASS=A 1823 +ATZ 1991 1991 1992 -(% style="background-color:#dcdcdc" %)**AT+CLASS=A 1993 -ATZ** 1994 -))) 1995 1995 1996 1996 1997 - 1998 1998 = 5. FAQ = 1999 1999 2000 2000 ... ... @@ -2014,14 +2014,12 @@ 2014 2014 2015 2015 ((( 2016 2016 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 2017 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http s://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].1846 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]]. 2018 2018 (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 2019 2019 2020 2020 2021 -((( 2022 2022 (% style="color:blue" %)**For LT-22222-L**(%%): 2023 2023 Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 2024 -))) 2025 2025 2026 2026 2027 2027 ))) ... ... @@ -2072,7 +2072,6 @@ 2072 2072 ((( 2073 2073 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 2074 2074 2075 - 2076 2076 2077 2077 ))) 2078 2078 ))) ... ... @@ -2079,14 +2079,10 @@ 2079 2079 2080 2080 ((( 2081 2081 (% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2082 - 2083 - 2084 2084 ))) 2085 2085 2086 2086 ((( 2087 2087 [[image:1653360231087-571.png||height="401" width="727"]] 2088 - 2089 - 2090 2090 ))) 2091 2091 2092 2092 ((( ... ... @@ -2094,23 +2094,21 @@ 2094 2094 ))) 2095 2095 2096 2096 2097 - 2098 2098 ((( 2099 2099 (% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2100 - 2101 - 2102 2102 ))) 2103 2103 2104 2104 ((( 2105 -(% style="background-color:#dcdcdc" %)**123456** (%%) : Enter Password to have AT access. 2106 -(% style="background-color:#dcdcdc" %)**AT+FDR**(%%) : Reset Parameters to Factory Default, Keys Reserve 2107 -(% style="background-color:#dcdcdc" %)**AT+NJM=0** (%%) : Set to ABP mode 2108 -(% style="background-color:#dcdcdc" %)**AT+ADR=0** (%%) : Set the Adaptive Data Rate Off 2109 -(% style="background-color:#dcdcdc" %)**AT+DR=5** (%%) : Set Data Rate (Set AT+DR=3 for 915 band) 2110 -(% style="background-color:#dcdcdc" %)**AT+TDC=60000 **(%%) : Set transmit interval to 60 seconds 2111 -(% style="background-color:#dcdcdc" %)**AT+CHS=868400000**(%%) : Set transmit frequency to 868.4Mhz 2112 -(% style="background-color:#dcdcdc" %)**AT+DADDR=26 01 1A F1**(%%) : Set Device Address to 26 01 1A F1 2113 -(% style="background-color:#dcdcdc" %)**ATZ** (%%) : Reset MCU 1924 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1925 +(% style="background-color:#dcdcdc" %)AT+FDR(%%) Reset Parameters to Factory Default, Keys Reserve 1926 +(% style="background-color:#dcdcdc" %)123456 (%%) Enter Password to have AT access. 1927 +(% style="background-color:#dcdcdc" %)AT+NJM=0 (%%) Set to ABP mode 1928 +(% style="background-color:#dcdcdc" %)AT+ADR=0 (%%) Set the Adaptive Data Rate Off 1929 +(% style="background-color:#dcdcdc" %)AT+DR=5 (%%) Set Data Rate (Set AT+DR=3 for 915 band) 1930 +(% style="background-color:#dcdcdc" %)AT+TDC=60000 (%%) Set transmit interval to 60 seconds 1931 +(% style="background-color:#dcdcdc" %)AT+CHS=868400000(%%) Set transmit frequency to 868.4Mhz 1932 +(% style="background-color:#dcdcdc" %)AT+DADDR=26 01 1A F1(%%) Set Device Address to 26 01 1A F1 1933 +(% style="background-color:#dcdcdc" %)ATZ (%%) Reset MCU 2114 2114 ))) 2115 2115 2116 2116 ... ... @@ -2133,7 +2133,7 @@ 2133 2133 == 5.5 Can i use point to point communication for LT-22222-L? == 2134 2134 2135 2135 2136 -Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] ,this is [[firmware>>https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].1956 +Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 2137 2137 2138 2138 2139 2139 ... ... @@ -2153,19 +2153,7 @@ 2153 2153 2154 2154 2155 2155 2156 -== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2157 - 2158 - 2159 -LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: 2160 - 2161 - 2162 -[[image:image-20221006170630-1.png||height="610" width="945"]] 2163 - 2164 - 2165 - 2166 2166 = 6. Trouble Shooting = 2167 - 2168 - 2169 2169 ))) 2170 2170 2171 2171 ((( ... ... @@ -2225,6 +2225,10 @@ 2225 2225 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2226 2226 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 2227 2227 2036 + 2037 + 2038 + 2039 + 2228 2228 = 8. Packing Info = 2229 2229 2230 2230 ... ... @@ -2242,6 +2242,10 @@ 2242 2242 * Package Size / pcs : 14.5 x 8 x 5 cm 2243 2243 * Weight / pcs : 170g 2244 2244 2057 + 2058 + 2059 + 2060 + 2245 2245 = 9. Support = 2246 2246 2247 2247 ... ... @@ -2253,6 +2253,7 @@ 2253 2253 2254 2254 2255 2255 2072 + 2256 2256 2257 2257 ))) 2258 2258 ... ... @@ -2262,3 +2262,6 @@ 2262 2262 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 2263 2263 * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 2264 2264 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2082 + 2083 + 2084 +
- image-20221006170630-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -486.5 KB - Content
- image-20221008095908-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -41.8 KB - Content