Changes for page LSN50 & LSN50-V2 - LoRaWAN Sensor Node User Manual
Last modified by Mengting Qiu on 2025/06/04 10:46
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -60,15 +60,11 @@ 60 60 * Supply Voltage: built in 8500mAh Li-SOCI2 battery 61 61 * Operating Temperature: -40 ~~ 85°C 62 62 63 - 64 - 65 65 (% style="color:#037691" %)**Temperature Sensor:** 66 66 67 67 * Range: -55 to + 125°C 68 68 * Accuracy ±0.5°C (max ±2.0 °C). 69 69 70 - 71 - 72 72 (% style="color:#037691" %)**LoRa Spec:** 73 73 74 74 * Frequency Range, ... ... @@ -83,17 +83,11 @@ 83 83 * Automatic RF Sense and CAD with ultra-fast AFC. 84 84 * LoRaWAN 1.0.3 Specification 85 85 86 - 87 - 88 88 (% style="color:#037691" %)**Power Consumption** 89 89 90 90 * Sleeping Mode: 20uA 91 91 * LoRaWAN Transmit Mode: 125mA @ 20dBm 44mA @ 14dBm 92 92 93 - 94 - 95 - 96 - 97 97 == 1.3 Features == 98 98 99 99 * LoRaWAN v1.0.3 Class A ... ... @@ -152,10 +152,6 @@ 152 152 Cable Drawing: [[See This Link>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSN50v2-D20/Cable_Drawing/&file=CAB0-35IC-K31G-210811.pdf]] 153 153 ))) 154 154 155 - 156 - 157 - 158 - 159 159 == 1.6 Pin Definitions and Switch == 160 160 161 161 (% class="wikigeneratedid" %) ... ... @@ -424,6 +424,7 @@ 424 424 425 425 === 2.5.2 Sensor related commands === 426 426 413 +(% class="wikigeneratedid" %) 427 427 ==== ==== 428 428 429 429 ==== (% style="color:red" %)**Set Alarm Threshold:**(%%) ==== ... ... @@ -436,6 +436,7 @@ 436 436 * When min≠0, and max=0, Alarm trigger when lower than min 437 437 * When min≠0 and max≠0, Alarm trigger when higher than max or lower than min 438 438 426 + 439 439 **Example:** 440 440 441 441 AT+18ALARM=-10,30 ~/~/ Alarm when < -10 or higher than 30. ... ... @@ -458,6 +458,7 @@ 458 458 * 2: Temperature_White 459 459 * 3: Temperature_Black 460 460 449 + 461 461 **Example:** 462 462 463 463 AT+18ALARM=-10,30,1 ~/~/ Alarm when temperature_red < -10 or higher than 30. ... ... @@ -503,6 +503,8 @@ 503 503 504 504 * Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message. 505 505 495 + 496 + 506 506 == 2.6 LED Status == 507 507 508 508 LSN50-v2-D20 has an internal LED, it will active in below situation: ... ... @@ -512,6 +512,8 @@ 512 512 * If device successful join LoRaWAN network, the LED will be solid on for 5 seconds. 513 513 514 514 506 + 507 + 515 515 == 2.7 Button Function == 516 516 517 517 **Internal RESET button:** ... ... @@ -649,57 +649,33 @@ 649 649 650 650 = 5. FAQ = 651 651 652 -== 5.1WhatisthefrequencyrangefLSN50v2-D20?==645 +== 6.1 How to change the LoRa Frequency Bands/Region == 653 653 654 -Different LSN50V2-D20 version supports different frequency range, below is the table for the working frequency and recommend bands for each model: 647 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.9A0200BFirmwareChangeLog"]]. 648 +When downloading the images, choose the required image file for download. 655 655 656 -[[image:image-20220623100350-8.png]] 657 657 658 658 659 -= =5.2Whats the FrequencyPlan?==652 += 7. Trouble Shooting = 660 660 661 - PleasereferDraginoEnd Node Frequency Plan: [[EndDevice FrequencyBand>>doc:Main.End Device FrequencyBand.WebHome]]654 +== 7.1 AT Command input doesn't work == 662 662 656 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 663 663 664 - 665 -== 5.3 How to update the firmware? == 666 - 667 -User can upgrade the firmware for: 668 - 669 -* ((( 670 -Support new features 658 +((( 659 + 671 671 ))) 672 -* ((( 673 -For bug fix 674 -))) 675 -* ((( 676 -Change LoRaWAN bands. 677 -))) 678 678 679 -Please see this link for how to upgrade: ** **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 680 680 663 += 8. Order Info = 681 681 665 +== 8.1 Main Device LDDS04 == 682 682 683 - = 6. TroubleShooting=667 +Part Number **:** (% style="color:blue" %)**LDDS04-XX** 684 684 685 -== 6.1 AT Command input doesn't work == 686 686 687 - In the case if user can see the console output but can’t type input to the device. Please check if you already include the(% style="color:green" %)**ENTER**(%%)whilesending out thecommand. Some serialooldoesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key,user need toadd ENTER intheir string.670 +(% style="color:blue" %)**XX**(%%)**: **The default frequency band 688 688 689 - 690 - 691 -= 7. Order Info = 692 - 693 - 694 -**Part Number:** (% style="color:blue" %)**LSN50V2-D20-XXX (Signal Probe)** 695 - 696 -**~ Or (% style="color:blue" %)LSN50V2-D22-XXX (Dual Probe)(%%)** 697 - 698 -**~ Or (% style="color:blue" %)LSN50V2-D23-XXX (Triple Probe)(%%)** 699 - 700 - 701 -(% style="color:blue" %)**XXX**(%%)**: **The default frequency band 702 - 703 703 * (% style="color:red" %)**AS923 **(%%)**:** LoRaWAN AS923 band 704 704 * (% style="color:red" %)**AU915 **(%%)**:** LoRaWAN AU915 band 705 705 * (% style="color:red" %)**EU433 **(%%)**:** LoRaWAN EU433 band ... ... @@ -709,17 +709,22 @@ 709 709 * (% style="color:red" %)**IN865 **(%%)**:** LoRaWAN IN865 band 710 710 * (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band 711 711 681 +== 8.2 Probe Model == 712 712 683 +Detail See [[Probe Option>>path:#Probe_Option]] Section 713 713 685 +* A01A-15 686 +* A02-15 687 +* A13-15 688 +* A16-15 714 714 715 -= 8. Packing Info =690 += 9. Packing Info = 716 716 717 717 718 718 **Package Includes**: 719 719 720 -* LS N50v2-D2xLoRaWANTemperature Sensor x 1695 +* LDDS04 LoRaWAN 4-Channels Distance Sensor x 1 721 721 722 - 723 723 **Dimension and weight**: 724 724 725 725 * Device Size: cm ... ... @@ -727,10 +727,7 @@ 727 727 * Package Size / pcs : cm 728 728 * Weight / pcs : g 729 729 704 += 10. Support = 730 730 731 - 732 - 733 -= 9. Support = 734 - 735 735 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 736 736 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].