Summary

Details

Page properties
Content
... ... @@ -410,7 +410,6 @@
410 410  
411 411  === 2.5.2 Sensor related commands ===
412 412  
413 -(% class="wikigeneratedid" %)
414 414  ==== ====
415 415  
416 416  ==== (% style="color:red" %)**Set Alarm Threshold:**(%%) ====
... ... @@ -423,7 +423,6 @@
423 423  * When min≠0, and max=0, Alarm trigger when lower than min
424 424  * When min≠0 and max≠0, Alarm trigger when higher than max or lower than min
425 425  
426 -
427 427  **Example:**
428 428  
429 429   AT+18ALARM=-10,30  ~/~/ Alarm when < -10 or higher than 30.
... ... @@ -446,7 +446,6 @@
446 446  * 2: Temperature_White
447 447  * 3: Temperature_Black
448 448  
449 -
450 450  **Example:**
451 451  
452 452   AT+18ALARM=-10,30,1   ~/~/ Alarm when temperature_red < -10 or higher than 30.
... ... @@ -493,7 +493,6 @@
493 493  * Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message.
494 494  
495 495  
496 -
497 497  == 2.6  LED Status ==
498 498  
499 499  LSN50-v2-D20 has an internal LED, it will active in below situation:
... ... @@ -504,7 +504,6 @@
504 504  
505 505  
506 506  
507 -
508 508  == 2.7  Button Function ==
509 509  
510 510  **Internal RESET button:**
... ... @@ -642,6 +642,37 @@
642 642  
643 643  = 5.  FAQ =
644 644  
640 +== 5.1 What is the frequency range of LSN50v2-D20? ==
641 +
642 +Different LSN50V2-D20 version supports different frequency range, below is the table for the working frequency and recommend bands for each model:
643 +
644 +[[image:image-20220623100350-8.png]]
645 +
646 +
647 +== 5.2 What is the Frequency Plan? ==
648 +
649 +Please refer Dragino End Node Frequency Plan:  [[End Device Frequency Band>>doc:Main.End Device Frequency Band.WebHome]]
650 +
651 +
652 +
653 +== 5.3 How to update the firmware? ==
654 +
655 +User can upgrade the firmware for:
656 +
657 +* (((
658 +Support new features
659 +)))
660 +* (((
661 +For bug fix
662 +)))
663 +* (((
664 +Change LoRaWAN bands.
665 +)))
666 +
667 +
668 +Please see this link for how to upgrade: ** **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
669 +
670 +
645 645  == 6.1  How to change the LoRa Frequency Bands/Region ==
646 646  
647 647  You can follow the instructions for [[how to upgrade image>>||anchor="H2.9A0200BFirmwareChangeLog"]].
... ... @@ -649,21 +649,19 @@
649 649  
650 650  
651 651  
652 -= 7.  Trouble Shooting =
678 += 6.  Trouble Shooting =
653 653  
654 -== 7.1  AT Command input doesn't work ==
680 +== 6.1  AT Command input doesn't work ==
655 655  
656 656  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
657 657  
658 -(((
659 -
660 -)))
661 661  
662 662  
663 -= 8.  Order Info =
664 664  
665 -== 8.1  Main Device LDDS04 ==
687 += 7Order Info =
666 666  
689 +== 7.1  Main Device LDDS04 ==
690 +
667 667  Part Number **:** (% style="color:blue" %)**LDDS04-XX**
668 668  
669 669  
... ... @@ -678,14 +678,8 @@
678 678  * (% style="color:red" %)**IN865 **(%%)**:**  LoRaWAN IN865 band
679 679  * (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band
680 680  
681 -== 8.2  Probe Model ==
682 682  
683 -Detail See [[Probe Option>>path:#Probe_Option]] Section
684 684  
685 -* A01A-15
686 -* A02-15
687 -* A13-15
688 -* A16-15
689 689  
690 690  = 9. ​ Packing Info =
691 691  
... ... @@ -701,6 +701,9 @@
701 701  * Package Size / pcs : cm
702 702  * Weight / pcs : g
703 703  
722 +
723 +
724 +
704 704  = 10.  ​Support =
705 705  
706 706  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.