Changes for page LSN50 & LSN50-V2 - LoRaWAN Sensor Node User Manual
Last modified by Mengting Qiu on 2025/06/04 10:46
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -410,7 +410,6 @@ 410 410 411 411 === 2.5.2 Sensor related commands === 412 412 413 -(% class="wikigeneratedid" %) 414 414 ==== ==== 415 415 416 416 ==== (% style="color:red" %)**Set Alarm Threshold:**(%%) ==== ... ... @@ -423,7 +423,6 @@ 423 423 * When min≠0, and max=0, Alarm trigger when lower than min 424 424 * When min≠0 and max≠0, Alarm trigger when higher than max or lower than min 425 425 426 - 427 427 **Example:** 428 428 429 429 AT+18ALARM=-10,30 ~/~/ Alarm when < -10 or higher than 30. ... ... @@ -446,7 +446,6 @@ 446 446 * 2: Temperature_White 447 447 * 3: Temperature_Black 448 448 449 - 450 450 **Example:** 451 451 452 452 AT+18ALARM=-10,30,1 ~/~/ Alarm when temperature_red < -10 or higher than 30. ... ... @@ -493,7 +493,6 @@ 493 493 * Alarm & MOD bit is 0x7C, 0x7C >> 2 = 0x31: Means this message is the Alarm settings message. 494 494 495 495 496 - 497 497 == 2.6 LED Status == 498 498 499 499 LSN50-v2-D20 has an internal LED, it will active in below situation: ... ... @@ -504,7 +504,6 @@ 504 504 505 505 506 506 507 - 508 508 == 2.7 Button Function == 509 509 510 510 **Internal RESET button:** ... ... @@ -541,7 +541,7 @@ 541 541 542 542 543 543 544 -== 4.2 Replace Battery ==539 +== 3.2 Replace Battery == 545 545 546 546 ((( 547 547 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. ... ... @@ -553,7 +553,7 @@ 553 553 554 554 555 555 556 -== 4.3 Power Consumption Analyze ==551 +== 3.3 Power Consumption Analyze == 557 557 558 558 ((( 559 559 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. ... ... @@ -598,7 +598,7 @@ 598 598 599 599 600 600 601 -=== 4.3.1 Battery Note ===596 +=== 3.3.1 Battery Note === 602 602 603 603 ((( 604 604 ((( ... ... @@ -608,7 +608,7 @@ 608 608 609 609 610 610 611 -=== 4.3.2 Replace the battery ===606 +=== 3.3.2 Replace the battery === 612 612 613 613 ((( 614 614 ((( ... ... @@ -624,43 +624,55 @@ 624 624 ))) 625 625 626 626 627 -= 5. Use AT Command =622 += 4. Use AT Command = 628 628 629 -== 5.1 Access AT Commands ==624 +== 4.1 Access AT Commands == 630 630 631 - LDDS04supports AT Command set in the stock firmware.Youcan use a USB to TTL adapter to connect to LDDS04forusingAT command,as below.626 +User can use a USB to TTL adapter to connect to LSN50V2-D20 to use AT command to configure the device. Example is as below: 632 632 633 -(% aria-label="1654940081538-914.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654940081538-914.png||data-widget="image"]](% style="background:url(~"http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 634 634 629 +[[image:image-20220623095817-4.png||height="665" width="1032"]] 635 635 636 - **Connection:**631 +(% style="display:none" %) (%%) 637 637 638 - (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**633 +[[image:image-20220623100044-7.png]] 639 639 640 -(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 641 641 642 -(% style=" background-color:yellow" %)**USBTTLRXD <~-~-~-~-> UART_TXD**636 +(% style="display:none" %) (%%) 643 643 638 += 5. FAQ = 644 644 645 -((( 646 -((( 647 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS04. 648 -))) 640 +== 5.1 What is the frequency range of LSN50v2-D20? == 649 649 650 -((( 651 -LDDS04 will output system info once power on as below: 652 -))) 653 -))) 642 +Different LSN50V2-D20 version supports different frequency range, below is the table for the working frequency and recommend bands for each model: 654 654 644 +[[image:image-20220623100350-8.png]] 655 655 656 - (% aria-label="1654593712276-618.png image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654593712276-618.png||data-widget="image"]](% style="background:url(~"http://wiki1.dragino.com/xwiki/webjars/wiki%3Axwiki/application-ckeditor-webjar/1.61/plugins/widget/images/handle.png~") rgba(220, 220, 220, 0.5); left:0px; top:-15px" %)[[image:data:image/gif;base64,R0lGODlhAQABAPABAP///wAAACH5BAEKAAAALAAAAAABAAEAAAICRAEAOw==||draggable="true" height="15" role="presentation" title="Click and drag to move" width="15"]](% title="Click and drag to resize" %) 657 657 658 - ValidATCommandpleasecheck[[ConfigureDevice>>||anchor="H3.A0ConfigureLDDS04viaATCommandorLoRaWANDownlink"]].647 +== 5.2 What is the Frequency Plan? == 659 659 649 +Please refer Dragino End Node Frequency Plan: [[End Device Frequency Band>>doc:Main.End Device Frequency Band.WebHome]] 660 660 661 661 662 -= 6. FAQ = 663 663 653 +== 5.3 How to update the firmware? == 654 + 655 +User can upgrade the firmware for: 656 + 657 +* ((( 658 +Support new features 659 +))) 660 +* ((( 661 +For bug fix 662 +))) 663 +* ((( 664 +Change LoRaWAN bands. 665 +))) 666 + 667 + 668 +Please see this link for how to upgrade: ** **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 669 + 670 + 664 664 == 6.1 How to change the LoRa Frequency Bands/Region == 665 665 666 666 You can follow the instructions for [[how to upgrade image>>||anchor="H2.9A0200BFirmwareChangeLog"]]. ... ... @@ -668,21 +668,19 @@ 668 668 669 669 670 670 671 -= 7. Trouble Shooting =678 += 6. Trouble Shooting = 672 672 673 -== 7.1 AT Command input doesn't work ==680 +== 6.1 AT Command input doesn't work == 674 674 675 675 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 676 676 677 -((( 678 - 679 -))) 680 680 681 681 682 -= 8. Order Info = 683 683 684 -= =8.1Main DeviceLDDS04==687 += 7. Order Info = 685 685 689 +== 7.1 Main Device LDDS04 == 690 + 686 686 Part Number **:** (% style="color:blue" %)**LDDS04-XX** 687 687 688 688 ... ... @@ -697,14 +697,8 @@ 697 697 * (% style="color:red" %)**IN865 **(%%)**:** LoRaWAN IN865 band 698 698 * (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band 699 699 700 -== 8.2 Probe Model == 701 701 702 -Detail See [[Probe Option>>path:#Probe_Option]] Section 703 703 704 -* A01A-15 705 -* A02-15 706 -* A13-15 707 -* A16-15 708 708 709 709 = 9. Packing Info = 710 710 ... ... @@ -720,6 +720,9 @@ 720 720 * Package Size / pcs : cm 721 721 * Weight / pcs : g 722 722 722 + 723 + 724 + 723 723 = 10. Support = 724 724 725 725 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
- image-20220623100044-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +168.8 KB - Content
- image-20220623100350-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +15.5 KB - Content