Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Xiaoling on 2025/04/25 10:32
From version 58.1
edited by Bei Jinggeng
on 2024/08/02 16:47
on 2024/08/02 16:47
Change comment:
There is no comment for this version
To version 57.1
edited by Bei Jinggeng
on 2024/03/30 17:39
on 2024/03/30 17:39
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -283,7 +283,7 @@ 283 283 === 2.3.7 MOD === 284 284 285 285 286 -Firmware version at least v 1.2.1 supports changing mode.286 +Firmware version at least v2.1 supports changing mode. 287 287 288 288 For example, bytes[10]=90 289 289 ... ... @@ -310,7 +310,7 @@ 310 310 ))) 311 311 312 312 ((( 313 -LSE01 TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/ blob/main/LSE01/LSE01_TTN%20Decoder%20V1.2.1.txt>>https://github.com/dragino/dragino-end-node-decoder/blob/main/LSE01/LSE01_TTN%20Decoder%20V1.2.1.txt]]313 +LSE01 TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSE01>>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSE01]] 314 314 315 315 316 316 ))) ... ... @@ -1036,44 +1036,6 @@ 1036 1036 1037 1037 = = 1038 1038 1039 - 1040 -== 5.4 The node cannot read the sensor data == 1041 - 1042 -This may be caused by a software firmware(≤1.1.6 version) bug, which we fixed in the latest firmware (>1.1.6 version) 1043 - 1044 -The user can fix this problem via upgrade firmware. 1045 - 1046 -By default, The latest firmware value of POWERIC is 1, while the 3322 version requires POWERIC to be set to 0 in order to function properly 1047 - 1048 -* **//1. Check if the hardware version is 3322//** 1049 - 1050 -If the sensor hardware version is 3322 or earlier, the user can change the POWERIC value to 0 after a firmware upgrade using one of the following methods 1051 - 1052 - 1053 -**a. Using AT command** 1054 - 1055 -(% class="box infomessage" %) 1056 -((( 1057 -AT+POWERIC=0. 1058 -))) 1059 - 1060 - 1061 -**b. Using Downlink** 1062 - 1063 -(% class="box infomessage" %) 1064 -((( 1065 -FF 00(AT+POWERIC=0). 1066 -))) 1067 - 1068 -[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20240531090837-1.png?rev=1.1||alt="image-20240531090837-1.png"]] 1069 - 1070 -Please check your hardware production date 1071 - 1072 -The first two digits are the week of the year, and the last two digits are the year. 1073 - 1074 -The number 3322 is the first batch we changed the power IC. 1075 - 1076 - 1077 1077 = 6. Order Info = 1078 1078 1079 1079