Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Mengting Qiu on 2025/07/07 15:27
From version 57.3
edited by Xiaoling
on 2024/07/01 10:43
on 2024/07/01 10:43
Change comment:
There is no comment for this version
To version 60.1
edited by Mengting Qiu
on 2025/07/07 15:27
on 2025/07/07 15:27
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -1,5 +1,4 @@ 1 -(% style="text-align:center" %) 2 -[[image:image-20220606151504-2.jpeg||height="554" width="554"]] 1 +[[image:image-20220606151504-2.jpeg||data-xwiki-image-style-alignment="center" height="554" width="554"]] 3 3 4 4 5 5 ... ... @@ -148,33 +148,57 @@ 148 148 149 149 Each LSE01 is shipped with a sticker with the default device EUI as below: 150 150 151 -[[image:image-20230426084640-1.png||height="2 41" width="519"]]150 +[[image:image-20230426084640-1.png||height="201" width="433"]] 152 152 153 153 154 154 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: 155 155 156 -** AddAPP EUI inthe application**155 +**Create the application.** 157 157 157 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SAC01L_LoRaWAN_Temperature%26Humidity_Sensor_User_Manual/WebHome/image-20250423093843-1.png?width=756&height=264&rev=1.1||alt="image-20250423093843-1.png"]] 158 158 159 -[[image: 1654504596150-405.png]]159 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111305-2.png?width=1000&height=572&rev=1.1||alt="image-20240907111305-2.png"]] 160 160 161 161 162 +**Add devices to the created Application.** 162 162 163 - **AddPP KEY andDEV EUI**164 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111659-3.png?width=977&height=185&rev=1.1||alt="image-20240907111659-3.png"]] 164 164 165 -[[image:1 654504683289-357.png]]166 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111820-5.png?width=975&height=377&rev=1.1||alt="image-20240907111820-5.png"]] 166 166 167 167 169 +**Enter end device specifics manually.** 168 168 169 - (% style="color:blue"%)**Step2**(%%): PowerLSE01171 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112136-6.png?width=697&height=687&rev=1.1||alt="image-20240907112136-6.png"]] 170 170 173 +**Add DevEUI and AppKey.** 171 171 175 +**Customize a platform ID for the device.** 176 + 177 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112427-7.png?rev=1.1||alt="image-20240907112427-7.png"]] 178 + 179 + 180 +(% style="color:blue" %)**Step 2**(%%):** Add decoder.** 181 + 182 +In TTN, user can add a custom payload so it shows friendly reading. 183 + 184 +Click this link to get the decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/]] 185 + 186 +Below is TTN screen shot: 187 + 188 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS25-LBLDS25-LS--LoRaWAN_LiDAR_Distance_Auto-Clean_Sensor_User_Manual/WebHome/image-20241009140556-1.png?width=1184&height=488&rev=1.1||alt="image-20241009140556-1.png" height="488" width="1184"]] 189 + 190 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS25-LBLDS25-LS--LoRaWAN_LiDAR_Distance_Auto-Clean_Sensor_User_Manual/WebHome/image-20241009140603-2.png?width=1168&height=562&rev=1.1||alt="image-20241009140603-2.png"]] 191 + 192 + 193 +(% style="color:blue" %)**Step 3**(%%): Power on LSE01 194 + 172 172 Put a Jumper on JP2 to power on the device. ( The Jumper must be in FLASH position). 173 173 174 174 [[image:image-20220606163915-7.png]] 175 175 176 176 177 - (% style="color:blue" %)**Step 3**(%%)**:**The LSE01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.200 +The LSE01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 178 178 179 179 [[image:1654504778294-788.png]] 180 180 ... ... @@ -367,6 +367,7 @@ 367 367 ))) 368 368 369 369 393 + 370 370 * (% style="color:blue" %)**CFM** 371 371 372 372 Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0 ... ... @@ -976,6 +976,7 @@ 976 976 977 977 978 978 1003 + 979 979 == 4.2 Can I calibrate LSE01 to different soil types? == 980 980 981 981 ... ... @@ -1024,7 +1024,7 @@ 1024 1024 [[image:1654500929571-736.png||height="458" width="832"]] 1025 1025 1026 1026 1027 -== 5. 3Possible reasons why the device is unresponsive: ==1052 +== 5.4 Possible reasons why the device is unresponsive: == 1028 1028 1029 1029 ~1. Check whether the battery voltage is lower than 2.8V 1030 1030 2. Check whether the jumper of the device is correctly connected ... ... @@ -1036,6 +1036,44 @@ 1036 1036 1037 1037 = = 1038 1038 1064 + 1065 +== 5.4 The node cannot read the sensor data == 1066 + 1067 +This may be caused by a software firmware(≤1.1.6 version) bug, which we fixed in the latest firmware (>1.1.6 version) 1068 + 1069 +The user can fix this problem via upgrade firmware. 1070 + 1071 +By default, The latest firmware value of POWERIC is 1, while the 3322 version requires POWERIC to be set to 0 in order to function properly 1072 + 1073 +* **//1. Check if the hardware version is 3322//** 1074 + 1075 +If the sensor hardware version is 3322 or earlier, the user can change the POWERIC value to 0 after a firmware upgrade using one of the following methods 1076 + 1077 + 1078 +**a. Using AT command** 1079 + 1080 +(% class="box infomessage" %) 1081 +((( 1082 +AT+POWERIC=0. 1083 +))) 1084 + 1085 + 1086 +**b. Using Downlink** 1087 + 1088 +(% class="box infomessage" %) 1089 +((( 1090 +FF 00(AT+POWERIC=0). 1091 +))) 1092 + 1093 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20240531090837-1.png?rev=1.1||alt="image-20240531090837-1.png"]] 1094 + 1095 +Please check your hardware production date 1096 + 1097 +The first two digits are the week of the year, and the last two digits are the year. 1098 + 1099 +The number 3322 is the first batch we changed the power IC. 1100 + 1101 + 1039 1039 = 6. Order Info = 1040 1040 1041 1041