Last modified by Xiaoling on 2025/04/25 10:32

From version 57.3
edited by Xiaoling
on 2024/07/01 10:43
Change comment: There is no comment for this version
To version 58.2
edited by Xiaoling
on 2025/04/25 10:06
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -148,33 +148,57 @@
148 148  
149 149  Each LSE01 is shipped with a sticker with the default device EUI as below:
150 150  
151 -[[image:image-20230426084640-1.png||height="241" width="519"]]
151 +[[image:image-20230426084640-1.png||height="201" width="433"]]
152 152  
153 153  
154 154  You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot:
155 155  
156 -**Add APP EUI in the application**
156 +**Create the application.**
157 157  
158 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SAC01L_LoRaWAN_Temperature%26Humidity_Sensor_User_Manual/WebHome/image-20250423093843-1.png?width=756&height=264&rev=1.1||alt="image-20250423093843-1.png"]]
158 158  
159 -[[image:1654504596150-405.png]]
160 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111305-2.png?width=1000&height=572&rev=1.1||alt="image-20240907111305-2.png"]]
160 160  
161 161  
163 +**Add devices to the created Application.**
162 162  
163 -**Add APP KEY and DEV EUI**
165 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111659-3.png?width=977&height=185&rev=1.1||alt="image-20240907111659-3.png"]]
164 164  
165 -[[image:1654504683289-357.png]]
167 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907111820-5.png?width=975&height=377&rev=1.1||alt="image-20240907111820-5.png"]]
166 166  
167 167  
170 +**Enter end device specifics manually.**
168 168  
169 -(% style="color:blue" %)**Step 2**(%%): Power on LSE01
172 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112136-6.png?width=697&height=687&rev=1.1||alt="image-20240907112136-6.png"]]
170 170  
174 +**Add DevEUI and AppKey.**
171 171  
176 +**Customize a platform ID for the device.**
177 +
178 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LTC2-LB--LoRaWAN_Temperature_Transmitter_User_Manual/WebHome/image-20240907112427-7.png?rev=1.1||alt="image-20240907112427-7.png"]]
179 +
180 +
181 +(% style="color:blue" %)**Step 2**(%%):** Add decoder.**
182 +
183 +In TTN, user can add a custom payload so it shows friendly reading.
184 +
185 +Click this link to get the decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/]]
186 +
187 +Below is TTN screen shot:
188 +
189 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS25-LBLDS25-LS--LoRaWAN_LiDAR_Distance_Auto-Clean_Sensor_User_Manual/WebHome/image-20241009140556-1.png?width=1184&height=488&rev=1.1||alt="image-20241009140556-1.png" height="488" width="1184"]]
190 +
191 +[[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDS25-LBLDS25-LS--LoRaWAN_LiDAR_Distance_Auto-Clean_Sensor_User_Manual/WebHome/image-20241009140603-2.png?width=1168&height=562&rev=1.1||alt="image-20241009140603-2.png"]]
192 +
193 +
194 +(% style="color:blue" %)**Step 3**(%%): Power on LSE01
195 +
172 172  Put a Jumper on JP2 to power on the device. ( The Jumper must be in FLASH position).
173 173  
174 174  [[image:image-20220606163915-7.png]]
175 175  
176 176  
177 -(% style="color:blue" %)**Step 3**(%%)**:** The LSE01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
201 +The LSE01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.
178 178  
179 179  [[image:1654504778294-788.png]]
180 180  
... ... @@ -1036,6 +1036,44 @@
1036 1036  
1037 1037  = =
1038 1038  
1063 +
1064 +== 5.4 The node cannot read the sensor data ==
1065 +
1066 +This may be caused by a software firmware(≤1.1.6 version) bug, which we fixed in the latest firmware (>1.1.6 version)
1067 +
1068 +The user can fix this problem via upgrade firmware.
1069 +
1070 +By default, The latest firmware value of POWERIC is 1, while the 3322 version requires POWERIC to be set to 0 in order to function properly
1071 +
1072 +* **//1. Check if the hardware version is 3322//**
1073 +
1074 +If the sensor hardware version is 3322 or earlier, the user can change the POWERIC value to 0 after a firmware upgrade using one of the following methods
1075 +
1076 +
1077 +**a. Using AT command**
1078 +
1079 +(% class="box infomessage" %)
1080 +(((
1081 +AT+POWERIC=0.
1082 +)))
1083 +
1084 +
1085 +**b. Using Downlink**
1086 +
1087 +(% class="box infomessage" %)
1088 +(((
1089 +FF 00(AT+POWERIC=0).
1090 +)))
1091 +
1092 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20240531090837-1.png?rev=1.1||alt="image-20240531090837-1.png"]]
1093 +
1094 +Please check your hardware production date
1095 +
1096 +The first two digits are the week of the year, and the last two digits are the year.
1097 +
1098 +The number 3322 is the first batch we changed the power IC.
1099 +
1100 +
1039 1039  = 6. ​Order Info =
1040 1040  
1041 1041