Last modified by Xiaoling on 2025/04/25 10:32

From version 54.1
edited by Bei Jinggeng
on 2024/03/30 17:33
Change comment: There is no comment for this version
To version 58.1
edited by Bei Jinggeng
on 2024/08/02 16:47
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -283,7 +283,7 @@
283 283  === 2.3.7 MOD ===
284 284  
285 285  
286 -Firmware version at least v2.1 supports changing mode.
286 +Firmware version at least v1.2.1 supports changing mode.
287 287  
288 288  For example, bytes[10]=90
289 289  
... ... @@ -310,7 +310,7 @@
310 310  )))
311 311  
312 312  (((
313 -LSE01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSE01>>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSE01]]
313 +LSE01 TTN Payload Decoder:  [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/blob/main/LSE01/LSE01_TTN%20Decoder%20V1.2.1.txt>>https://github.com/dragino/dragino-end-node-decoder/blob/main/LSE01/LSE01_TTN%20Decoder%20V1.2.1.txt]]
314 314  
315 315  
316 316  )))
... ... @@ -1029,14 +1029,51 @@
1029 1029  ~1. Check whether the battery voltage is lower than 2.8V
1030 1030  2. Check whether the jumper of the device is correctly connected
1031 1031  
1032 -[[image:image-20240330173015-1.png]]
1032 +[[image:image-20240330173910-1.png]]
1033 1033  3. Check whether the switch here of the device is at the ISP(The switch can operate normally only when it is in RUN)
1034 1034  
1035 -[[image:image-20240330173044-2.png]]
1035 +[[image:image-20240330173932-2.png]]
1036 1036  
1037 -(% class="wikigeneratedid" %)
1038 1038  = =
1039 1039  
1039 +
1040 +== 5.4 The node cannot read the sensor data ==
1041 +
1042 +This may be caused by a software firmware(≤1.1.6 version) bug, which we fixed in the latest firmware (>1.1.6 version)
1043 +
1044 +The user can fix this problem via upgrade firmware.
1045 +
1046 +By default, The latest firmware value of POWERIC is 1, while the 3322 version requires POWERIC to be set to 0 in order to function properly
1047 +
1048 +* **//1. Check if the hardware version is 3322//**
1049 +
1050 +If the sensor hardware version is 3322 or earlier, the user can change the POWERIC value to 0 after a firmware upgrade using one of the following methods
1051 +
1052 +
1053 +**a. Using AT command**
1054 +
1055 +(% class="box infomessage" %)
1056 +(((
1057 +AT+POWERIC=0.
1058 +)))
1059 +
1060 +
1061 +**b. Using Downlink**
1062 +
1063 +(% class="box infomessage" %)
1064 +(((
1065 +FF 00(AT+POWERIC=0).
1066 +)))
1067 +
1068 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LDDS75%20-%20LoRaWAN%20Distance%20Detection%20Sensor%20User%20Manual/WebHome/image-20240531090837-1.png?rev=1.1||alt="image-20240531090837-1.png"]]
1069 +
1070 +Please check your hardware production date
1071 +
1072 +The first two digits are the week of the year, and the last two digits are the year.
1073 +
1074 +The number 3322 is the first batch we changed the power IC.
1075 +
1076 +
1040 1040  = 6. ​Order Info =
1041 1041  
1042 1042  
image-20240330173910-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +445.4 KB
Content
image-20240330173932-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +445.4 KB
Content