Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,11 +92,13 @@ 92 92 Method 93 93 )))|(% style="width:146px" %)FDR , with temperature &EC compensate|(% style="width:137px" %)Conductivity , with temperature compensate|(% style="width:140px" %)RTD, and calibrate 94 94 95 +[[image:image-20220606162220-5.png]] 95 95 97 + 96 96 == 1.4 Dimension == 97 97 98 98 99 - (% style="color:blue" %)**Main Device Dimension:**101 +**Main Device Dimension:** 100 100 101 101 See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 102 102 ... ... @@ -103,7 +103,7 @@ 103 103 [[image:image-20221008140228-2.png||height="358" width="571"]] 104 104 105 105 106 - (% style="color:blue" %)**Probe Dimension**108 +**Probe Dimension** 107 107 108 108 [[image:image-20221008135912-1.png]] 109 109 ... ... @@ -149,7 +149,7 @@ 149 149 150 150 Each LSE01 is shipped with a sticker with the default device EUI as below: 151 151 152 -[[image:image-20230426084640-1.png ||height="241" width="519"]]154 +[[image:image-20230426084640-1.png]] 153 153 154 154 155 155 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: ... ... @@ -182,7 +182,7 @@ 182 182 183 183 == 2.3 Uplink Payload == 184 184 185 -=== 2.3.1 MOD~=0(Default Mode) (%style="display:none" %) (%%)===187 +=== 2.3.1 MOD~=0(Default Mode) === 186 186 187 187 188 188 LSE01 will uplink payload via LoRaWAN with below payload format: ... ... @@ -191,8 +191,10 @@ 191 191 Uplink payload includes in total 11 bytes. 192 192 ))) 193 193 194 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 195 -|=**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1** 196 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 197 +|=(% scope="row" %)((( 198 +**Size(bytes)** 199 +)))|**2**|**2**|**2**|**2**|**2**|**1** 196 196 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 197 197 Temperature 198 198 (Reserve, Ignore now) ... ... @@ -205,8 +205,10 @@ 205 205 206 206 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 207 207 208 -(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 209 -|=**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1** 212 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 213 +|=(% scope="row" %)((( 214 +**Size(bytes)** 215 +)))|**2**|**2**|**2**|**2**|**2**|**1** 210 210 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 211 211 Temperature 212 212 (Reserve, Ignore now)