Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -73,36 +73,29 @@ 73 73 Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. 74 74 75 75 (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:520px" %) 76 -|(% style=" width:95px;background-color:#D9E2F3;color:#0070C0" %)**Parameter**|(% style="width:146px;background-color:#D9E2F3;color:#0070C0" %)**Soil Moisture**|(% style="width:137px;background-color:#D9E2F3;color:#0070C0" %)**Soil Conductivity**|(% style="width:140px;background-color:#D9E2F3;color:#0070C0" %)**Soil Temperature**76 +|(% style="background-color:#d9e2f3; color:#0070c0; width:95px" %)**Parameter**|(% style="background-color:#d9e2f3; color:#0070c0; width:147px" %)**Soil Moisture**|(% style="background-color:#d9e2f3; color:#0070c0; width:138px" %)**Soil Conductivity**|(% style="background-color:#d9e2f3; color:#0070c0; width:140px" %)**Soil Temperature** 77 77 |(% style="width:95px" %)Range|(% style="width:146px" %)0-100.00%|(% style="width:137px" %)((( 78 78 0-20000uS/cm 79 - 80 80 (25℃)(0-20.0EC) 81 81 )))|(% style="width:140px" %)-40.00℃~85.00℃ 82 -|(% style="width:95px" %)Unit|(% style="width:146px" %)V/V % ,|(% style="width:137px" %)uS/cm,|(% style="width:140px" %)℃81 +|(% style="width:95px" %)Unit|(% style="width:146px" %)V/V %|(% style="width:137px" %)uS/cm|(% style="width:140px" %)℃ 83 83 |(% style="width:95px" %)Resolution|(% style="width:146px" %)0.01%|(% style="width:137px" %)1 uS/cm|(% style="width:140px" %)0.01℃ 84 84 |(% style="width:95px" %)Accuracy|(% style="width:146px" %)((( 85 85 ±3% (0-53%) 86 - 87 87 ±5% (>53%) 88 -)))|(% style="width:137px" %)2%FS ,|(% style="width:140px" %)(((86 +)))|(% style="width:137px" %)2%FS|(% style="width:140px" %)((( 89 89 -10℃~50℃:<0.3℃ 90 - 91 91 All other: <0.6℃ 92 92 ))) 93 93 |(% style="width:95px" %)((( 94 94 Measure 95 - 96 96 Method 97 97 )))|(% style="width:146px" %)FDR , with temperature &EC compensate|(% style="width:137px" %)Conductivity , with temperature compensate|(% style="width:140px" %)RTD, and calibrate 98 98 99 -[[image:image-20220606162220-5.png]] 100 - 101 - 102 102 == 1.4 Dimension == 103 103 104 104 105 -**Main Device Dimension:** 98 +(% style="color:blue" %)**Main Device Dimension:** 106 106 107 107 See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 108 108 ... ... @@ -109,7 +109,7 @@ 109 109 [[image:image-20221008140228-2.png||height="358" width="571"]] 110 110 111 111 112 -**Probe Dimension** 105 +(% style="color:blue" %)**Probe Dimension** 113 113 114 114 [[image:image-20221008135912-1.png]] 115 115 ... ... @@ -155,7 +155,7 @@ 155 155 156 156 Each LSE01 is shipped with a sticker with the default device EUI as below: 157 157 158 -[[image:image-20230426084640-1.png]] 151 +[[image:image-20230426084640-1.png||height="241" width="519"]] 159 159 160 160 161 161 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: ... ... @@ -188,7 +188,7 @@ 188 188 189 189 == 2.3 Uplink Payload == 190 190 191 -=== 2.3.1 MOD~=0(Default Mode) === 184 +=== 2.3.1 MOD~=0(Default Mode)(% style="display:none" %) (%%) === 192 192 193 193 194 194 LSE01 will uplink payload via LoRaWAN with below payload format: ... ... @@ -197,10 +197,8 @@ 197 197 Uplink payload includes in total 11 bytes. 198 198 ))) 199 199 200 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 201 -|=(% scope="row" %)((( 202 -**Size(bytes)** 203 -)))|**2**|**2**|**2**|**2**|**2**|**1** 193 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 194 +|=**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1** 204 204 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 205 205 Temperature 206 206 (Reserve, Ignore now) ... ... @@ -213,10 +213,8 @@ 213 213 214 214 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 215 215 216 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 217 -|=(% scope="row" %)((( 218 -**Size(bytes)** 219 -)))|**2**|**2**|**2**|**2**|**2**|**1** 207 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %) 208 +|=**Size(bytes)**|**2**|**2**|**2**|**2**|**2**|**1** 220 220 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 221 221 Temperature 222 222 (Reserve, Ignore now) ... ... @@ -309,7 +309,7 @@ 309 309 mod=(bytes[10]>>7)&0x01=1. 310 310 311 311 312 -**Downlink Command:** 301 +(% style="color:blue" %)**Downlink Command:** 313 313 314 314 If payload = 0x0A00, workmode=0 315 315 ... ... @@ -329,10 +329,11 @@ 329 329 ))) 330 330 331 331 ((( 332 -LSE01 TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 321 +LSE01 TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder/tree/main/LSE01>>https://github.com/dragino/dragino-end-node-decoder/tree/main/LSE01]] 322 + 323 + 333 333 ))) 334 334 335 - 336 336 == 2.4 Uplink Interval == 337 337 338 338 ... ... @@ -344,9 +344,16 @@ 344 344 345 345 By default, LSE01 prints the downlink payload to console port. 346 346 347 -[[image:image-20220606165544-8.png]] 337 +(% border="1" cellspacing="5" style="background-color:#f2f2f2; width:520px" %) 338 +|=(% style="width: 183px; background-color:#D9E2F3;color:#0070C0" %)**Downlink Control Type**|=(% style="width: 55px; background-color:#D9E2F3;color:#0070C0" %)FPort|=(% style="width: 93px; background-color:#D9E2F3;color:#0070C0" %)**Type Code**|=(% style="width: 189px;background-color:#D9E2F3;color:#0070C0" %)**Downlink payload size(bytes)** 339 +|(% style="width:183px" %)TDC (Transmit Time Interval)|(% style="width:55px" %)Any|(% style="width:93px" %)01|(% style="width:188px" %)4 340 +|(% style="width:183px" %)RESET|(% style="width:55px" %)Any|(% style="width:93px" %)004|(% style="width:188px" %)2 341 +|(% style="width:183px" %)AT+CFM|(% style="width:55px" %)Any|(% style="width:93px" %)05|(% style="width:188px" %)4 342 +|(% style="width:183px" %)INTMOD|(% style="width:55px" %)Any|(% style="width:93px" %)A6|(% style="width:188px" %)4 343 +|(% style="width:183px" %)MOD|(% style="width:55px" %)Any|(% style="width:93px" %)A7|(% style="width:188px" %)2 348 348 349 349 346 + 350 350 ((( 351 351 (% style="color:blue" %)**Examples:** 352 352 )))