Last modified by Mengting Qiu on 2025/07/07 15:27

From version 47.23
edited by Xiaoling
on 2023/05/31 11:13
Change comment: There is no comment for this version
To version 53.1
edited by Mengting Qiu
on 2023/11/11 09:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.ting
Content
... ... @@ -30,7 +30,7 @@
30 30  )))
31 31  
32 32  (((
33 -It detects (% style="color:blue" %)**Soil Moisture**(%%), (% style="color:#4f81bd" %)**Soil Temperature**(%%) and (% style="color:blue" %)**Soil Conductivity**(%%), and uploads the value via wireless to LoRaWAN IoT Server.
33 +It detects (% style="color:blue" %)**Soil Moisture**(%%), (% style="color:blue" %)**Soil Temperature**(%%) and (% style="color:blue" %)**Soil Conductivity**(%%), and uploads the value via wireless to LoRaWAN IoT Server.
34 34  )))
35 35  
36 36  (((
... ... @@ -67,7 +67,6 @@
67 67  * IP66 Waterproof Enclosure
68 68  * 4000mAh or 8500mAh Battery for long term use
69 69  
70 -
71 71  == 1.3 Specification ==
72 72  
73 73  
... ... @@ -93,7 +93,6 @@
93 93  Method
94 94  )))|(% style="width:146px" %)FDR , with temperature &EC compensate|(% style="width:137px" %)Conductivity , with temperature compensate|(% style="width:140px" %)RTD, and calibrate
95 95  
96 -
97 97  == 1.4 Dimension ==
98 98  
99 99  
... ... @@ -114,7 +114,6 @@
114 114  
115 115  * Smart Agriculture​
116 116  
117 -
118 118  == 1.6 Firmware Change log ==
119 119  
120 120  
... ... @@ -194,8 +194,8 @@
194 194  )))
195 195  
196 196  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
197 -|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
198 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
194 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
195 +|Value|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
199 199  Temperature
200 200  (Reserve, Ignore now)
201 201  )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
... ... @@ -202,7 +202,6 @@
202 202  MOD & Digital Interrupt(Optional)
203 203  )))
204 204  
205 -
206 206  === 2.3.2 MOD~=1(Original value) ===
207 207  
208 208  
... ... @@ -209,15 +209,14 @@
209 209  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
210 210  
211 211  (% border="1" cellspacing="5" style="background-color:#f2f2f2; width:500px" %)
212 -|(% style="background-color:#D9E2F3;color:#0070C0" %)**Size(bytes)**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**2**|(% style="background-color:#D9E2F3;color:#0070C0" %)**1**
213 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
208 +|(% style="background-color:#d9e2f3; color:#0070c0" %)**Size(bytes)**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**2**|(% style="background-color:#d9e2f3; color:#0070c0" %)**1**
209 +|Value|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
214 214  Temperature
215 215  (Reserve, Ignore now)
216 -)))|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Dielectric constant>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
212 +)))|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|Dielectric constant(raw)|(((
217 217  MOD & Digital Interrupt(Optional)
218 218  )))
219 219  
220 -
221 221  === 2.3.3 Battery Info ===
222 222  
223 223  
... ... @@ -242,18 +242,10 @@
242 242  )))
243 243  
244 244  (((
245 -For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
240 +For example, if the data you get from the register is **__0x05 0xDC__**, the moisture content in the soil is (% style="color:blue" %)**05DC(H) = 1500(D) /100 = 15%.**
246 246  )))
247 247  
248 -(((
249 -
250 -)))
251 251  
252 -(((
253 -(% style="color:blue" %)**05DC(H) = 1500(D) /100 = 15%.**
254 -)))
255 -
256 -
257 257  === 2.3.5 Soil Temperature ===
258 258  
259 259  
... ... @@ -351,10 +351,6 @@
351 351  (% style="color:blue" %)**Examples:**
352 352  )))
353 353  
354 -(((
355 -
356 -)))
357 -
358 358  * (((
359 359  (% style="color:blue" %)**Set TDC**
360 360  )))
... ... @@ -715,7 +715,6 @@
715 715  * Solid ON for 5 seconds once device successful Join the network.
716 716  * Blink once when device transmit a packet.
717 717  
718 -
719 719  == 2.9 Installation in Soil ==
720 720  
721 721  
... ... @@ -781,13 +781,13 @@
781 781  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
782 782  
783 783  
784 -[[image:1654501986557-872.png||height="391" width="800"]]
766 +[[image:image-20231111095033-3.png||height="591" width="855"]]
785 785  
786 786  
787 787  Or if you have below board, use below connection:
788 788  
789 789  
790 -[[image:1654502005655-729.png||height="503" width="801"]]
772 +[[image:image-20231109094023-1.png]]
791 791  
792 792  
793 793  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
image-20231109094023-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +809.6 KB
Content
image-20231111093716-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
image-20231111095027-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +4.7 MB
Content
image-20231111095033-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +4.7 MB
Content