Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -22,6 +22,7 @@ 22 22 23 23 = 1. Introduction = 24 24 25 + 25 25 == 1.1 What is LoRaWAN Soil Moisture & EC Sensor == 26 26 27 27 ... ... @@ -52,6 +52,7 @@ 52 52 [[image:1654503265560-120.png]] 53 53 54 54 56 + 55 55 == 1.2 Features == 56 56 57 57 ... ... @@ -67,8 +67,6 @@ 67 67 * IP66 Waterproof Enclosure 68 68 * 4000mAh or 8500mAh Battery for long term use 69 69 70 - 71 - 72 72 == 1.3 Specification == 73 73 74 74 ... ... @@ -77,6 +77,7 @@ 77 77 [[image:image-20220606162220-5.png]] 78 78 79 79 80 + 80 80 == 1.4 Dimension == 81 81 82 82 ... ... @@ -92,13 +92,12 @@ 92 92 [[image:image-20221008135912-1.png]] 93 93 94 94 96 + 95 95 == 1.5 Applications == 96 96 97 97 98 98 * Smart Agriculture 99 99 100 - 101 - 102 102 == 1.6 Firmware Change log == 103 103 104 104 ... ... @@ -105,8 +105,10 @@ 105 105 **LSE01 v1.0 :** Release 106 106 107 107 108 + 108 108 = 2. Configure LSE01 to connect to LoRaWAN network = 109 109 111 + 110 110 == 2.1 How it works == 111 111 112 112 ... ... @@ -119,6 +119,7 @@ 119 119 ))) 120 120 121 121 124 + 122 122 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 123 123 124 124 ... ... @@ -166,8 +166,10 @@ 166 166 [[image:1654504778294-788.png]] 167 167 168 168 172 + 169 169 == 2.3 Uplink Payload == 170 170 175 + 171 171 === 2.3.1 MOD~=0(Default Mode) === 172 172 173 173 ... ... @@ -189,7 +189,6 @@ 189 189 ))) 190 190 191 191 192 - 193 193 === 2.3.2 MOD~=1(Original value) === 194 194 195 195 ... ... @@ -207,7 +207,6 @@ 207 207 ))) 208 208 209 209 210 - 211 211 === 2.3.3 Battery Info === 212 212 213 213 ... ... @@ -224,6 +224,7 @@ 224 224 ))) 225 225 226 226 230 + 227 227 === 2.3.4 Soil Moisture === 228 228 229 229 ... ... @@ -244,11 +244,12 @@ 244 244 ))) 245 245 246 246 251 + 247 247 === 2.3.5 Soil Temperature === 248 248 249 249 250 250 ((( 251 -Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is 256 + Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is 252 252 ))) 253 253 254 254 ((( ... ... @@ -264,6 +264,7 @@ 264 264 ))) 265 265 266 266 272 + 267 267 === 2.3.6 Soil Conductivity (EC) === 268 268 269 269 ... ... @@ -283,6 +283,10 @@ 283 283 284 284 ))) 285 285 292 +((( 293 + 294 +))) 295 + 286 286 === 2.3.7 MOD === 287 287 288 288 ... ... @@ -300,6 +300,7 @@ 300 300 If** **payload =** **0x0A01, workmode=1 301 301 302 302 313 + 303 303 === 2.3.8 Decode payload in The Things Network === 304 304 305 305 ... ... @@ -317,6 +317,7 @@ 317 317 ))) 318 318 319 319 331 + 320 320 == 2.4 Uplink Interval == 321 321 322 322 ... ... @@ -323,6 +323,7 @@ 323 323 The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 324 324 325 325 338 + 326 326 == 2.5 Downlink Payload == 327 327 328 328 ... ... @@ -373,6 +373,7 @@ 373 373 Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0 374 374 375 375 389 + 376 376 == 2.6 Show Data in DataCake IoT Server == 377 377 378 378 ... ... @@ -412,6 +412,7 @@ 412 412 [[image:1654505925508-181.png]] 413 413 414 414 429 + 415 415 == 2.7 Frequency Plans == 416 416 417 417 ... ... @@ -418,6 +418,7 @@ 418 418 The LSE01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 419 419 420 420 436 + 421 421 === 2.7.1 EU863-870 (EU868) === 422 422 423 423 ... ... @@ -449,6 +449,7 @@ 449 449 869.525 - SF9BW125 (RX2 downlink only) 450 450 451 451 468 + 452 452 === 2.7.2 US902-928(US915) === 453 453 454 454 ... ... @@ -494,6 +494,7 @@ 494 494 923.3 - SF12BW500(RX2 downlink only) 495 495 496 496 514 + 497 497 === 2.7.3 CN470-510 (CN470) === 498 498 499 499 ... ... @@ -539,6 +539,7 @@ 539 539 505.3 - SF12BW125 (RX2 downlink only) 540 540 541 541 560 + 542 542 === 2.7.4 AU915-928(AU915) === 543 543 544 544 ... ... @@ -584,6 +584,7 @@ 584 584 923.3 - SF12BW500(RX2 downlink only) 585 585 586 586 606 + 587 587 === 2.7.5 AS920-923 & AS923-925 (AS923) === 588 588 589 589 ... ... @@ -635,6 +635,7 @@ 635 635 923.2 - SF10BW125 (RX2) 636 636 637 637 658 + 638 638 === 2.7.6 KR920-923 (KR920) === 639 639 640 640 ... ... @@ -671,6 +671,7 @@ 671 671 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125) 672 672 673 673 695 + 674 674 === 2.7.7 IN865-867 (IN865) === 675 675 676 676 ... ... @@ -690,6 +690,8 @@ 690 690 866.550 - SF10BW125 (RX2) 691 691 692 692 715 + 716 + 693 693 == 2.8 LED Indicator == 694 694 695 695 ... ... @@ -700,7 +700,6 @@ 700 700 * Blink once when device transmit a packet. 701 701 702 702 703 - 704 704 == 2.9 Installation in Soil == 705 705 706 706 ... ... @@ -730,6 +730,7 @@ 730 730 ))) 731 731 732 732 756 + 733 733 == 2.10 Firmware Change Log == 734 734 735 735 ... ... @@ -738,6 +738,10 @@ 738 738 ))) 739 739 740 740 ((( 765 + 766 +))) 767 + 768 +((( 741 741 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 742 742 ))) 743 743 ... ... @@ -754,16 +754,70 @@ 754 754 ))) 755 755 756 756 757 -== 2.11 Battery & Power Consumption == 758 758 786 +== 2.11 Battery Analysis == 759 759 760 -LSE01 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 761 761 762 - [[**BatteryInfo & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]].789 +=== 2.11.1 Battery Type === 763 763 764 764 792 +((( 793 +The LSE01 battery is a combination of a 4000mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 794 +))) 795 + 796 +((( 797 +The battery is designed to last for more than 5 years for the LSN50. 798 +))) 799 + 800 +((( 801 +((( 802 +The battery-related documents are as below: 803 +))) 804 +))) 805 + 806 +* ((( 807 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 808 +))) 809 +* ((( 810 +[[Lithium-Thionyl Chloride Battery datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], 811 +))) 812 +* ((( 813 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]] 814 +))) 815 + 816 + [[image:image-20220610172436-1.png]] 817 + 818 + 819 + 820 +=== 2.11.2 Battery Note === 821 + 822 + 823 +((( 824 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 825 +))) 826 + 827 + 828 + 829 +=== 2.11.3 Replace the battery === 830 + 831 + 832 +((( 833 +If Battery is lower than 2.7v, user should replace the battery of LSE01. 834 +))) 835 + 836 +((( 837 +You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 838 +))) 839 + 840 +((( 841 +The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 842 +))) 843 + 844 + 845 + 765 765 = 3. Using the AT Commands = 766 766 848 + 767 767 == 3.1 Access AT Commands == 768 768 769 769 ... ... @@ -779,6 +779,7 @@ 779 779 [[image:1654502005655-729.png||height="503" width="801"]] 780 780 781 781 864 + 782 782 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below: 783 783 784 784 ... ... @@ -893,8 +893,10 @@ 893 893 (% style="background-color:#dcdcdc" %)**AT+CHE**(%%) : Get or Set eight channels mode, Only for US915, AU915, CN470 894 894 895 895 979 + 896 896 = 4. FAQ = 897 897 982 + 898 898 == 4.1 How to change the LoRa Frequency Bands/Region? == 899 899 900 900 ... ... @@ -966,6 +966,7 @@ 966 966 [[image:image-20220606154825-4.png]] 967 967 968 968 1054 + 969 969 == 4.2 Can I calibrate LSE01 to different soil types? == 970 970 971 971 ... ... @@ -974,8 +974,10 @@ 974 974 ))) 975 975 976 976 1063 + 977 977 = 5. Trouble Shooting = 978 978 1066 + 979 979 == 5.1 Why I can't join TTN in US915 / AU915 bands? == 980 980 981 981 ... ... @@ -982,6 +982,7 @@ 982 982 It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 983 983 984 984 1073 + 985 985 == 5.2 AT Command input doesn't work == 986 986 987 987 ... ... @@ -990,6 +990,7 @@ 990 990 ))) 991 991 992 992 1082 + 993 993 == 5.3 Device rejoin in at the second uplink packet == 994 994 995 995 ... ... @@ -1014,6 +1014,7 @@ 1014 1014 [[image:1654500929571-736.png||height="458" width="832"]] 1015 1015 1016 1016 1107 + 1017 1017 = 6. Order Info = 1018 1018 1019 1019