<
From version < 46.2 >
edited by Xiaoling
on 2022/12/21 18:21
To version < 45.3 >
edited by Xiaoling
on 2022/10/27 11:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -22,6 +22,7 @@
22 22  
23 23  = 1. Introduction =
24 24  
25 +
25 25  == 1.1 ​What is LoRaWAN Soil Moisture & EC Sensor ==
26 26  
27 27  
... ... @@ -52,6 +52,7 @@
52 52  [[image:1654503265560-120.png]]
53 53  
54 54  
56 +
55 55  == 1.2 ​Features ==
56 56  
57 57  
... ... @@ -68,7 +68,6 @@
68 68  * 4000mAh or 8500mAh Battery for long term use
69 69  
70 70  
71 -
72 72  == 1.3 Specification ==
73 73  
74 74  
... ... @@ -77,28 +77,27 @@
77 77  [[image:image-20220606162220-5.png]]
78 78  
79 79  
81 +
80 80  == 1.4 Dimension ==
81 81  
82 82  
83 -**Main Device Dimension:**
85 +Main Device Dimension:
84 84  
85 85  See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]]
86 86  
87 87  [[image:image-20221008140228-2.png||height="358" width="571"]]
88 88  
91 +Probe Dimension
89 89  
90 -**Probe Dimension**
91 -
92 92  [[image:image-20221008135912-1.png]]
93 93  
94 94  
96 +
95 95  == ​1.5 Applications ==
96 96  
97 97  
98 98  * Smart Agriculture​
99 99  
100 -
101 -
102 102  == 1.6 Firmware Change log ==
103 103  
104 104  
... ... @@ -105,8 +105,10 @@
105 105  **LSE01 v1.0 :**  Release
106 106  
107 107  
108 +
108 108  = 2. Configure LSE01 to connect to LoRaWAN network =
109 109  
111 +
110 110  == 2.1 How it works ==
111 111  
112 112  
... ... @@ -119,6 +119,7 @@
119 119  )))
120 120  
121 121  
124 +
122 122  == 2.2 ​Quick guide to connect to LoRaWAN server (OTAA) ==
123 123  
124 124  
... ... @@ -166,8 +166,10 @@
166 166  [[image:1654504778294-788.png]]
167 167  
168 168  
172 +
169 169  == 2.3 Uplink Payload ==
170 170  
175 +
171 171  === 2.3.1 MOD~=0(Default Mode) ===
172 172  
173 173  
... ... @@ -177,37 +177,45 @@
177 177  Uplink payload includes in total 11 bytes.
178 178  )))
179 179  
180 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %)
181 -|=(% scope="row" %)(((
182 -**Size(bytes)**
185 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
186 +|(((
187 +**Size**
188 +
189 +**(bytes)**
183 183  )))|**2**|**2**|**2**|**2**|**2**|**1**
184 -|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
191 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
185 185  Temperature
193 +
186 186  (Reserve, Ignore now)
187 187  )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
188 -MOD & Digital Interrupt(Optional)
196 +MOD & Digital Interrupt
197 +
198 +(Optional)
189 189  )))
190 190  
191 191  
192 -
193 193  === 2.3.2 MOD~=1(Original value) ===
194 194  
195 195  
196 196  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
197 197  
198 -(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %)
199 -|=(% scope="row" %)(((
200 -**Size(bytes)**
207 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
208 +|(((
209 +**Size**
210 +
211 +**(bytes)**
201 201  )))|**2**|**2**|**2**|**2**|**2**|**1**
202 -|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
213 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
203 203  Temperature
215 +
204 204  (Reserve, Ignore now)
205 -)))|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Dielectric constant>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
206 -MOD & Digital Interrupt(Optional)
217 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
218 +MOD & Digital Interrupt
219 +
220 +(Optional)
207 207  )))
208 208  
209 209  
210 -
211 211  === 2.3.3 Battery Info ===
212 212  
213 213  
... ... @@ -224,6 +224,7 @@
224 224  )))
225 225  
226 226  
240 +
227 227  === 2.3.4 Soil Moisture ===
228 228  
229 229  
... ... @@ -244,11 +244,12 @@
244 244  )))
245 245  
246 246  
261 +
247 247  === 2.3.5 Soil Temperature ===
248 248  
249 249  
250 250  (((
251 -Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
266 + Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
252 252  )))
253 253  
254 254  (((
... ... @@ -264,6 +264,7 @@
264 264  )))
265 265  
266 266  
282 +
267 267  === 2.3.6 Soil Conductivity (EC) ===
268 268  
269 269  
... ... @@ -283,6 +283,10 @@
283 283  
284 284  )))
285 285  
302 +(((
303 +
304 +)))
305 +
286 286  === 2.3.7 MOD ===
287 287  
288 288  
... ... @@ -300,6 +300,7 @@
300 300  If** **payload =** **0x0A01, workmode=1
301 301  
302 302  
323 +
303 303  === 2.3.8 ​Decode payload in The Things Network ===
304 304  
305 305  
... ... @@ -317,6 +317,7 @@
317 317  )))
318 318  
319 319  
341 +
320 320  == 2.4 Uplink Interval ==
321 321  
322 322  
... ... @@ -323,6 +323,7 @@
323 323  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
324 324  
325 325  
348 +
326 326  == 2.5 Downlink Payload ==
327 327  
328 328  
... ... @@ -373,6 +373,7 @@
373 373  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
374 374  
375 375  
399 +
376 376  == 2.6 ​Show Data in DataCake IoT Server ==
377 377  
378 378  
... ... @@ -412,6 +412,7 @@
412 412  [[image:1654505925508-181.png]]
413 413  
414 414  
439 +
415 415  == 2.7 Frequency Plans ==
416 416  
417 417  
... ... @@ -418,6 +418,7 @@
418 418  The LSE01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
419 419  
420 420  
446 +
421 421  === 2.7.1 EU863-870 (EU868) ===
422 422  
423 423  
... ... @@ -449,6 +449,7 @@
449 449  869.525 - SF9BW125 (RX2 downlink only)
450 450  
451 451  
478 +
452 452  === 2.7.2 US902-928(US915) ===
453 453  
454 454  
... ... @@ -494,6 +494,7 @@
494 494  923.3 - SF12BW500(RX2 downlink only)
495 495  
496 496  
524 +
497 497  === 2.7.3 CN470-510 (CN470) ===
498 498  
499 499  
... ... @@ -539,6 +539,7 @@
539 539  505.3 - SF12BW125 (RX2 downlink only)
540 540  
541 541  
570 +
542 542  === 2.7.4 AU915-928(AU915) ===
543 543  
544 544  
... ... @@ -584,6 +584,7 @@
584 584  923.3 - SF12BW500(RX2 downlink only)
585 585  
586 586  
616 +
587 587  === 2.7.5 AS920-923 & AS923-925 (AS923) ===
588 588  
589 589  
... ... @@ -635,6 +635,7 @@
635 635  923.2 - SF10BW125 (RX2)
636 636  
637 637  
668 +
638 638  === 2.7.6 KR920-923 (KR920) ===
639 639  
640 640  
... ... @@ -671,6 +671,7 @@
671 671  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
672 672  
673 673  
705 +
674 674  === 2.7.7 IN865-867 (IN865) ===
675 675  
676 676  
... ... @@ -690,6 +690,8 @@
690 690  866.550 - SF10BW125 (RX2)
691 691  
692 692  
725 +
726 +
693 693  == 2.8 LED Indicator ==
694 694  
695 695  
... ... @@ -699,8 +699,6 @@
699 699  * Solid ON for 5 seconds once device successful Join the network.
700 700  * Blink once when device transmit a packet.
701 701  
702 -
703 -
704 704  == 2.9 Installation in Soil ==
705 705  
706 706  
... ... @@ -730,6 +730,7 @@
730 730  )))
731 731  
732 732  
765 +
733 733  == 2.10 ​Firmware Change Log ==
734 734  
735 735  
... ... @@ -738,6 +738,10 @@
738 738  )))
739 739  
740 740  (((
774 +
775 +)))
776 +
777 +(((
741 741  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
742 742  )))
743 743  
... ... @@ -754,8 +754,10 @@
754 754  )))
755 755  
756 756  
794 +
757 757  == 2.11 ​Battery Analysis ==
758 758  
797 +
759 759  === 2.11.1 ​Battery Type ===
760 760  
761 761  
... ... @@ -786,6 +786,7 @@
786 786   [[image:image-20220610172436-1.png]]
787 787  
788 788  
828 +
789 789  === 2.11.2 ​Battery Note ===
790 790  
791 791  
... ... @@ -794,6 +794,7 @@
794 794  )))
795 795  
796 796  
837 +
797 797  === 2.11.3 Replace the battery ===
798 798  
799 799  
... ... @@ -810,8 +810,10 @@
810 810  )))
811 811  
812 812  
854 +
813 813  = 3. ​Using the AT Commands =
814 814  
857 +
815 815  == 3.1 Access AT Commands ==
816 816  
817 817  
... ... @@ -827,6 +827,7 @@
827 827  [[image:1654502005655-729.png||height="503" width="801"]]
828 828  
829 829  
873 +
830 830  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
831 831  
832 832  
... ... @@ -941,8 +941,10 @@
941 941   (% style="background-color:#dcdcdc" %)**AT+CHE**(%%)  : Get or Set eight channels mode, Only for US915, AU915, CN470
942 942  
943 943  
988 +
944 944  = ​4. FAQ =
945 945  
991 +
946 946  == 4.1 ​How to change the LoRa Frequency Bands/Region? ==
947 947  
948 948  
... ... @@ -1014,16 +1014,17 @@
1014 1014  [[image:image-20220606154825-4.png]]
1015 1015  
1016 1016  
1063 +
1017 1017  == 4.2 ​Can I calibrate LSE01 to different soil types? ==
1018 1018  
1019 1019  
1020 -(((
1021 1021  LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
1022 -)))
1023 1023  
1024 1024  
1070 +
1025 1025  = 5. Trouble Shooting =
1026 1026  
1073 +
1027 1027  == 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1028 1028  
1029 1029  
... ... @@ -1030,6 +1030,7 @@
1030 1030  It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
1031 1031  
1032 1032  
1080 +
1033 1033  == 5.2 AT Command input doesn't work ==
1034 1034  
1035 1035  
... ... @@ -1038,6 +1038,7 @@
1038 1038  )))
1039 1039  
1040 1040  
1089 +
1041 1041  == 5.3 Device rejoin in at the second uplink packet ==
1042 1042  
1043 1043  
... ... @@ -1055,13 +1055,12 @@
1055 1055  
1056 1056  (% style="color:#4f81bd" %)**Solution: **
1057 1057  
1058 -(((
1059 1059  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
1060 -)))
1061 1061  
1062 1062  [[image:1654500929571-736.png||height="458" width="832"]]
1063 1063  
1064 1064  
1112 +
1065 1065  = 6. ​Order Info =
1066 1066  
1067 1067  
... ... @@ -1131,5 +1131,4 @@
1131 1131  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1132 1132  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1133 1133  
1134 -
1135 1135  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0