Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -187,13 +187,11 @@ 187 187 **Size(bytes)** 188 188 )))|**2**|**2**|**2**|**2**|**2**|**1** 189 189 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 190 -Temperature 191 -(Reserve, Ignore now) 190 +Temperature(Reserve, Ignore now) 192 192 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|((( 193 193 MOD & Digital Interrupt(Optional) 194 194 ))) 195 195 196 - 197 197 === 2.3.2 MOD~=1(Original value) === 198 198 199 199 ... ... @@ -204,13 +204,11 @@ 204 204 **Size(bytes)** 205 205 )))|**2**|**2**|**2**|**2**|**2**|**1** 206 206 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 207 -Temperature 208 -(Reserve, Ignore now) 209 -)))|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Dielectric constant>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 205 +Temperature(Reserve, Ignore now) 206 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 210 210 MOD & Digital Interrupt(Optional) 211 211 ))) 212 212 213 - 214 214 === 2.3.3 Battery Info === 215 215 216 216 ... ... @@ -723,7 +723,6 @@ 723 723 * Solid ON for 5 seconds once device successful Join the network. 724 724 * Blink once when device transmit a packet. 725 725 726 - 727 727 == 2.9 Installation in Soil == 728 728 729 729 ... ... @@ -1055,9 +1055,7 @@ 1055 1055 == 4.2 Can I calibrate LSE01 to different soil types? == 1056 1056 1057 1057 1058 -((( 1059 1059 LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1060 -))) 1061 1061 1062 1062 1063 1063 ... ... @@ -1097,9 +1097,7 @@ 1097 1097 1098 1098 (% style="color:#4f81bd" %)**Solution: ** 1099 1099 1100 -((( 1101 1101 All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below: 1102 -))) 1103 1103 1104 1104 [[image:1654500929571-736.png||height="458" width="832"]] 1105 1105