Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -187,11 +187,13 @@ 187 187 **Size(bytes)** 188 188 )))|**2**|**2**|**2**|**2**|**2**|**1** 189 189 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 190 -Temperature(Reserve, Ignore now) 190 +Temperature 191 +(Reserve, Ignore now) 191 191 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|((( 192 192 MOD & Digital Interrupt(Optional) 193 193 ))) 194 194 196 + 195 195 === 2.3.2 MOD~=1(Original value) === 196 196 197 197 ... ... @@ -202,11 +202,13 @@ 202 202 **Size(bytes)** 203 203 )))|**2**|**2**|**2**|**2**|**2**|**1** 204 204 |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 205 -Temperature(Reserve, Ignore now) 206 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 207 +Temperature 208 +(Reserve, Ignore now) 209 +)))|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Dielectric constant>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 207 207 MOD & Digital Interrupt(Optional) 208 208 ))) 209 209 213 + 210 210 === 2.3.3 Battery Info === 211 211 212 212 ... ... @@ -719,6 +719,7 @@ 719 719 * Solid ON for 5 seconds once device successful Join the network. 720 720 * Blink once when device transmit a packet. 721 721 726 + 722 722 == 2.9 Installation in Soil == 723 723 724 724 ... ... @@ -1050,7 +1050,9 @@ 1050 1050 == 4.2 Can I calibrate LSE01 to different soil types? == 1051 1051 1052 1052 1058 +((( 1053 1053 LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1060 +))) 1054 1054 1055 1055 1056 1056 ... ... @@ -1090,7 +1090,9 @@ 1090 1090 1091 1091 (% style="color:#4f81bd" %)**Solution: ** 1092 1092 1100 +((( 1093 1093 All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below: 1102 +))) 1094 1094 1095 1095 [[image:1654500929571-736.png||height="458" width="832"]] 1096 1096