From version < 45.4 >
edited by Xiaoling
on 2022/10/27 11:50
To version < 45.6 >
edited by Xiaoling
on 2022/10/27 11:58
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -187,11 +187,14 @@
187 187  **Size(bytes)**
188 188  )))|**2**|**2**|**2**|**2**|**2**|**1**
189 189  |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
190 -Temperature(Reserve, Ignore now)
190 +Temperature
191 +(Reserve, Ignore now)
191 191  )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
192 192  MOD & Digital Interrupt(Optional)
193 193  )))
194 194  
196 +
197 +
195 195  === 2.3.2 MOD~=1(Original value) ===
196 196  
197 197  
... ... @@ -202,11 +202,14 @@
202 202  **Size(bytes)**
203 203  )))|**2**|**2**|**2**|**2**|**2**|**1**
204 204  |=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
205 -Temperature(Reserve, Ignore now)
208 +Temperature
209 +(Reserve, Ignore now)
206 206  )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
207 207  MOD & Digital Interrupt(Optional)
208 208  )))
209 209  
214 +
215 +
210 210  === 2.3.3 Battery Info ===
211 211  
212 212  
... ... @@ -719,6 +719,8 @@
719 719  * Solid ON for 5 seconds once device successful Join the network.
720 720  * Blink once when device transmit a packet.
721 721  
728 +
729 +
722 722  == 2.9 Installation in Soil ==
723 723  
724 724  
... ... @@ -1050,7 +1050,9 @@
1050 1050  == 4.2 ​Can I calibrate LSE01 to different soil types? ==
1051 1051  
1052 1052  
1061 +(((
1053 1053  LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
1063 +)))
1054 1054  
1055 1055  
1056 1056  
... ... @@ -1090,7 +1090,9 @@
1090 1090  
1091 1091  (% style="color:#4f81bd" %)**Solution: **
1092 1092  
1103 +(((
1093 1093  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
1105 +)))
1094 1094  
1095 1095  [[image:1654500929571-736.png||height="458" width="832"]]
1096 1096  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0