Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,11 +22,11 @@ 22 22 23 23 = 1. Introduction = 24 24 25 - 26 26 == 1.1 What is LoRaWAN Soil Moisture & EC Sensor == 27 27 28 - 29 29 ((( 28 + 29 + 30 30 The Dragino LSE01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil Moisture & EC Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type. 31 31 ))) 32 32 ... ... @@ -70,6 +70,9 @@ 70 70 * 4000mAh or 8500mAh Battery for long term use 71 71 72 72 73 + 74 + 75 + 73 73 == 1.3 Specification == 74 74 75 75 ... ... @@ -79,29 +79,20 @@ 79 79 80 80 81 81 82 -== 1.4 Dimension ==85 +== 1.4 Applications == 83 83 84 84 85 - MainDeviceDimension:88 +* Smart Agriculture 86 86 87 -See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 90 +(% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %) 91 + 88 88 89 -[[image:image-20221008140228-2.png||height="358" width="571"]] 90 90 91 -Probe Dimension 92 92 93 -[[image:image-20221008135912-1.png]] 94 94 96 +== 1.5 Firmware Change log == 95 95 96 96 97 -== 1.5 Applications == 98 - 99 - 100 -* Smart Agriculture 101 - 102 -== 1.6 Firmware Change log == 103 - 104 - 105 105 **LSE01 v1.0 :** Release 106 106 107 107 ... ... @@ -199,6 +199,9 @@ 199 199 ))) 200 200 201 201 196 + 197 + 198 + 202 202 === 2.3.2 MOD~=1(Original value) === 203 203 204 204 ... ... @@ -221,6 +221,9 @@ 221 221 ))) 222 222 223 223 221 + 222 + 223 + 224 224 === 2.3.3 Battery Info === 225 225 226 226 ... ... @@ -334,7 +334,7 @@ 334 334 ))) 335 335 336 336 ((( 337 -LSE01 TTN Payload Decoder: [[https:~~/~~/ github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]]337 +LSE01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]] 338 338 ))) 339 339 340 340 ... ... @@ -733,6 +733,10 @@ 733 733 * Solid ON for 5 seconds once device successful Join the network. 734 734 * Blink once when device transmit a packet. 735 735 736 + 737 + 738 + 739 + 736 736 == 2.9 Installation in Soil == 737 737 738 738 ... ... @@ -985,13 +985,10 @@ 985 985 (% style="background-color:#dcdcdc" %)**AT+CHE**(%%) : Get or Set eight channels mode, Only for US915, AU915, CN470 986 986 987 987 988 - 989 989 = 4. FAQ = 990 990 991 - 992 992 == 4.1 How to change the LoRa Frequency Bands/Region? == 993 993 994 - 995 995 ((( 996 996 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 997 997 When downloading the images, choose the required image file for download. ... ... @@ -1060,36 +1060,27 @@ 1060 1060 [[image:image-20220606154825-4.png]] 1061 1061 1062 1062 1063 - 1064 1064 == 4.2 Can I calibrate LSE01 to different soil types? == 1065 1065 1066 - 1067 1067 LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1068 1068 1069 1069 1070 - 1071 1071 = 5. Trouble Shooting = 1072 1072 1073 - 1074 1074 == 5.1 Why I can't join TTN in US915 / AU915 bands? == 1075 1075 1076 - 1077 1077 It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 1078 1078 1079 1079 1080 - 1081 1081 == 5.2 AT Command input doesn't work == 1082 1082 1083 - 1084 1084 ((( 1085 1085 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1086 1086 ))) 1087 1087 1088 1088 1089 - 1090 1090 == 5.3 Device rejoin in at the second uplink packet == 1091 1091 1092 - 1093 1093 (% style="color:#4f81bd" %)**Issue describe as below:** 1094 1094 1095 1095 [[image:1654500909990-784.png]] ... ... @@ -1109,7 +1109,6 @@ 1109 1109 [[image:1654500929571-736.png||height="458" width="832"]] 1110 1110 1111 1111 1112 - 1113 1113 = 6. Order Info = 1114 1114 1115 1115 ... ... @@ -1175,8 +1175,5 @@ 1175 1175 1176 1176 = 8. Support = 1177 1177 1178 - 1179 1179 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1180 1180 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1181 - 1182 -
- image-20221008135912-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -65.9 KB - Content
- image-20221008140228-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -37.3 KB - Content