<
From version < 45.2 >
edited by Xiaoling
on 2022/10/13 17:12
To version < 46.1 >
edited by Bei Jinggeng
on 2022/12/21 15:01
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -25,9 +25,8 @@
25 25  
26 26  == 1.1 ​What is LoRaWAN Soil Moisture & EC Sensor ==
27 27  
28 -(((
29 -
30 30  
29 +(((
31 31  The Dragino LSE01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil Moisture & EC Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type.
32 32  )))
33 33  
... ... @@ -70,8 +70,6 @@
70 70  * IP66 Waterproof Enclosure
71 71  * 4000mAh or 8500mAh Battery for long term use
72 72  
73 -
74 -
75 75  == 1.3 Specification ==
76 76  
77 77  
... ... @@ -84,14 +84,15 @@
84 84  == 1.4 Dimension ==
85 85  
86 86  
87 -Main Device Dimension:
84 +**Main Device Dimension:**
88 88  
89 89  See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]]
90 90  
91 91  [[image:image-20221008140228-2.png||height="358" width="571"]]
92 92  
93 -Probe Dimension
94 94  
91 +**Probe Dimension**
92 +
95 95  [[image:image-20221008135912-1.png]]
96 96  
97 97  
... ... @@ -101,7 +101,6 @@
101 101  
102 102  * Smart Agriculture​
103 103  
104 -
105 105  == 1.6 Firmware Change log ==
106 106  
107 107  
... ... @@ -185,47 +185,35 @@
185 185  Uplink payload includes in total 11 bytes.
186 186  )))
187 187  
188 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
189 -|(((
190 -**Size**
191 -
192 -**(bytes)**
185 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %)
186 +|=(% scope="row" %)(((
187 +**Size(bytes)**
193 193  )))|**2**|**2**|**2**|**2**|**2**|**1**
194 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
189 +|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
195 195  Temperature
196 -
197 197  (Reserve, Ignore now)
198 198  )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
199 -MOD & Digital Interrupt
200 -
201 -(Optional)
193 +MOD & Digital Interrupt(Optional)
202 202  )))
203 203  
204 204  
205 -
206 206  === 2.3.2 MOD~=1(Original value) ===
207 207  
208 208  
209 209  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
210 210  
211 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
212 -|(((
213 -**Size**
214 -
215 -**(bytes)**
202 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %)
203 +|=(% scope="row" %)(((
204 +**Size(bytes)**
216 216  )))|**2**|**2**|**2**|**2**|**2**|**1**
217 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
206 +|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
218 218  Temperature
219 -
220 220  (Reserve, Ignore now)
221 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
222 -MOD & Digital Interrupt
223 -
224 -(Optional)
209 +)))|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Dielectric constant>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
210 +MOD & Digital Interrupt(Optional)
225 225  )))
226 226  
227 227  
228 -
229 229  === 2.3.3 Battery Info ===
230 230  
231 231  
... ... @@ -1070,7 +1070,9 @@
1070 1070  == 4.2 ​Can I calibrate LSE01 to different soil types? ==
1071 1071  
1072 1072  
1058 +(((
1073 1073  LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
1060 +)))
1074 1074  
1075 1075  
1076 1076  
... ... @@ -1110,7 +1110,9 @@
1110 1110  
1111 1111  (% style="color:#4f81bd" %)**Solution: **
1112 1112  
1100 +(((
1113 1113  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
1102 +)))
1114 1114  
1115 1115  [[image:1654500929571-736.png||height="458" width="832"]]
1116 1116  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0