Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -348,7 +348,6 @@ 348 348 349 349 == 2.5 Downlink Payload == 350 350 351 - 352 352 By default, LSE01 prints the downlink payload to console port. 353 353 354 354 [[image:image-20220606165544-8.png]] ... ... @@ -399,7 +399,6 @@ 399 399 400 400 == 2.6 Show Data in DataCake IoT Server == 401 401 402 - 403 403 ((( 404 404 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 405 405 ))) ... ... @@ -439,14 +439,11 @@ 439 439 440 440 == 2.7 Frequency Plans == 441 441 442 - 443 443 The LSE01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 444 444 445 445 446 - 447 447 === 2.7.1 EU863-870 (EU868) === 448 448 449 - 450 450 (% style="color:#037691" %)** Uplink:** 451 451 452 452 868.1 - SF7BW125 to SF12BW125 ... ... @@ -478,7 +478,6 @@ 478 478 479 479 === 2.7.2 US902-928(US915) === 480 480 481 - 482 482 Used in USA, Canada and South America. Default use CHE=2 483 483 484 484 (% style="color:#037691" %)**Uplink:** ... ... @@ -524,7 +524,6 @@ 524 524 525 525 === 2.7.3 CN470-510 (CN470) === 526 526 527 - 528 528 Used in China, Default use CHE=1 529 529 530 530 (% style="color:#037691" %)**Uplink:** ... ... @@ -570,7 +570,6 @@ 570 570 571 571 === 2.7.4 AU915-928(AU915) === 572 572 573 - 574 574 Default use CHE=2 575 575 576 576 (% style="color:#037691" %)**Uplink:** ... ... @@ -616,7 +616,6 @@ 616 616 617 617 === 2.7.5 AS920-923 & AS923-925 (AS923) === 618 618 619 - 620 620 (% style="color:#037691" %)**Default Uplink channel:** 621 621 622 622 923.2 - SF7BW125 to SF10BW125 ... ... @@ -668,7 +668,6 @@ 668 668 669 669 === 2.7.6 KR920-923 (KR920) === 670 670 671 - 672 672 Default channel: 673 673 674 674 922.1 - SF7BW125 to SF12BW125 ... ... @@ -705,7 +705,6 @@ 705 705 706 706 === 2.7.7 IN865-867 (IN865) === 707 707 708 - 709 709 (% style="color:#037691" %)** Uplink:** 710 710 711 711 865.0625 - SF7BW125 to SF12BW125 ... ... @@ -726,7 +726,6 @@ 726 726 727 727 == 2.8 LED Indicator == 728 728 729 - 730 730 The LSE01 has an internal LED which is to show the status of different state. 731 731 732 732 * Blink once when device power on. ... ... @@ -734,18 +734,13 @@ 734 734 * Blink once when device transmit a packet. 735 735 736 736 737 - 738 - 739 - 740 740 == 2.9 Installation in Soil == 741 741 742 - 743 743 **Measurement the soil surface** 744 744 745 745 746 746 [[image:1654506634463-199.png]] 747 747 748 - 749 749 ((( 750 750 ((( 751 751 Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting. ... ... @@ -756,7 +756,6 @@ 756 756 757 757 [[image:1654506665940-119.png]] 758 758 759 - 760 760 ((( 761 761 Dig a hole with diameter > 20CM. 762 762 ))) ... ... @@ -766,12 +766,14 @@ 766 766 ))) 767 767 768 768 769 - 770 770 == 2.10 Firmware Change Log == 771 771 753 +((( 754 +**Firmware download link:** 755 +))) 772 772 773 773 ((( 774 - **Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/8ixj7zgt477ip51/AADLrib9Oe6IuOpPF5o1GPf9a?dl=0>>https://www.dropbox.com/sh/8ixj7zgt477ip51/AADLrib9Oe6IuOpPF5o1GPf9a?dl=0]]758 +[[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 775 775 ))) 776 776 777 777 ((( ... ... @@ -795,13 +795,10 @@ 795 795 ))) 796 796 797 797 798 - 799 799 == 2.11 Battery Analysis == 800 800 801 - 802 802 === 2.11.1 Battery Type === 803 803 804 - 805 805 ((( 806 806 The LSE01 battery is a combination of a 4000mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 807 807 ))) ... ... @@ -832,7 +832,6 @@ 832 832 833 833 === 2.11.2 Battery Note === 834 834 835 - 836 836 ((( 837 837 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 838 838 ))) ... ... @@ -841,7 +841,6 @@ 841 841 842 842 === 2.11.3 Replace the battery === 843 843 844 - 845 845 ((( 846 846 If Battery is lower than 2.7v, user should replace the battery of LSE01. 847 847 ))) ... ... @@ -858,13 +858,11 @@ 858 858 859 859 = 3. Using the AT Commands = 860 860 861 - 862 862 == 3.1 Access AT Commands == 863 863 864 864 865 865 LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below. 866 866 867 - 868 868 [[image:1654501986557-872.png||height="391" width="800"]] 869 869 870 870 ... ... @@ -881,7 +881,7 @@ 881 881 [[image:1654502050864-459.png||height="564" width="806"]] 882 882 883 883 884 -Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]. 861 +Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]: [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]] 885 885 886 886 887 887 (% style="background-color:#dcdcdc" %)**AT+<CMD>? **(%%) : Help on <CMD> ... ... @@ -989,13 +989,10 @@ 989 989 (% style="background-color:#dcdcdc" %)**AT+CHE**(%%) : Get or Set eight channels mode, Only for US915, AU915, CN470 990 990 991 991 992 - 993 993 = 4. FAQ = 994 994 995 - 996 996 == 4.1 How to change the LoRa Frequency Bands/Region? == 997 997 998 - 999 999 ((( 1000 1000 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 1001 1001 When downloading the images, choose the required image file for download. ... ... @@ -1064,36 +1064,27 @@ 1064 1064 [[image:image-20220606154825-4.png]] 1065 1065 1066 1066 1067 - 1068 1068 == 4.2 Can I calibrate LSE01 to different soil types? == 1069 1069 1070 - 1071 1071 LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1072 1072 1073 1073 1074 - 1075 1075 = 5. Trouble Shooting = 1076 1076 1077 - 1078 1078 == 5.1 Why I can't join TTN in US915 / AU915 bands? == 1079 1079 1080 - 1081 1081 It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 1082 1082 1083 1083 1084 - 1085 1085 == 5.2 AT Command input doesn't work == 1086 1086 1087 - 1088 1088 ((( 1089 1089 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1090 1090 ))) 1091 1091 1092 1092 1093 - 1094 1094 == 5.3 Device rejoin in at the second uplink packet == 1095 1095 1096 - 1097 1097 (% style="color:#4f81bd" %)**Issue describe as below:** 1098 1098 1099 1099 [[image:1654500909990-784.png]] ... ... @@ -1113,7 +1113,6 @@ 1113 1113 [[image:1654500929571-736.png||height="458" width="832"]] 1114 1114 1115 1115 1116 - 1117 1117 = 6. Order Info = 1118 1118 1119 1119 ... ... @@ -1179,9 +1179,5 @@ 1179 1179 1180 1180 = 8. Support = 1181 1181 1182 - 1183 1183 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1184 1184 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1185 - 1186 - 1187 -