Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,11 +22,11 @@ 22 22 23 23 = 1. Introduction = 24 24 25 + 25 25 == 1.1 What is LoRaWAN Soil Moisture & EC Sensor == 26 26 27 -((( 28 - 29 29 29 +((( 30 30 The Dragino LSE01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil Moisture & EC Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type. 31 31 ))) 32 32 ... ... @@ -69,33 +69,39 @@ 69 69 * IP66 Waterproof Enclosure 70 70 * 4000mAh or 8500mAh Battery for long term use 71 71 72 +== 1.3 Specification == 72 72 73 73 75 +Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. 74 74 77 +[[image:image-20220606162220-5.png]] 75 75 76 -== 1.3 Specification == 77 77 78 78 79 - MeasureVolume: Base onthe centra pinof the probe, a cylinderwith 7cm diameter and 10cm height.81 +== 1.4 Dimension == 80 80 81 -[[image:image-20220606162220-5.png]] 82 82 84 +**Main Device Dimension:** 83 83 86 +See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 84 84 85 - == 1.4Applications==88 +[[image:image-20221008140228-2.png||height="358" width="571"]] 86 86 87 87 88 -* SmartAgriculture91 +**Probe Dimension** 89 89 90 -(% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %) 91 - 93 +[[image:image-20221008135912-1.png]] 92 92 93 93 94 94 97 +== 1.5 Applications == 95 95 96 -== 1.5 Firmware Change log == 97 97 100 +* Smart Agriculture 98 98 102 +== 1.6 Firmware Change log == 103 + 104 + 99 99 **LSE01 v1.0 :** Release 100 100 101 101 ... ... @@ -176,51 +176,37 @@ 176 176 Uplink payload includes in total 11 bytes. 177 177 ))) 178 178 179 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 180 -|((( 181 -**Size** 182 - 183 -**(bytes)** 185 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 186 +|=(% scope="row" %)((( 187 +**Size(bytes)** 184 184 )))|**2**|**2**|**2**|**2**|**2**|**1** 185 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 189 +|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 186 186 Temperature 187 - 188 188 (Reserve, Ignore now) 189 189 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|((( 190 -MOD & Digital Interrupt 191 - 192 -(Optional) 193 +MOD & Digital Interrupt(Optional) 193 193 ))) 194 194 195 195 196 196 197 - 198 - 199 199 === 2.3.2 MOD~=1(Original value) === 200 200 201 201 202 202 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 203 203 204 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 205 -|((( 206 -**Size** 207 - 208 -**(bytes)** 203 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 204 +|=(% scope="row" %)((( 205 +**Size(bytes)** 209 209 )))|**2**|**2**|**2**|**2**|**2**|**1** 210 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 207 +|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 211 211 Temperature 212 - 213 213 (Reserve, Ignore now) 214 214 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 215 -MOD & Digital Interrupt 216 - 217 -(Optional) 211 +MOD & Digital Interrupt(Optional) 218 218 ))) 219 219 220 220 221 221 222 - 223 - 224 224 === 2.3.3 Battery Info === 225 225 226 226 ... ... @@ -334,7 +334,7 @@ 334 334 ))) 335 335 336 336 ((( 337 -LSE01 TTN Payload Decoder: [[https:~~/~~/ www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]]329 +LSE01 TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 338 338 ))) 339 339 340 340 ... ... @@ -735,8 +735,6 @@ 735 735 736 736 737 737 738 - 739 - 740 740 == 2.9 Installation in Soil == 741 741 742 742 ... ... @@ -989,10 +989,13 @@ 989 989 (% style="background-color:#dcdcdc" %)**AT+CHE**(%%) : Get or Set eight channels mode, Only for US915, AU915, CN470 990 990 991 991 982 + 992 992 = 4. FAQ = 993 993 985 + 994 994 == 4.1 How to change the LoRa Frequency Bands/Region? == 995 995 988 + 996 996 ((( 997 997 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 998 998 When downloading the images, choose the required image file for download. ... ... @@ -1061,27 +1061,38 @@ 1061 1061 [[image:image-20220606154825-4.png]] 1062 1062 1063 1063 1057 + 1064 1064 == 4.2 Can I calibrate LSE01 to different soil types? == 1065 1065 1060 + 1061 +((( 1066 1066 LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1063 +))) 1067 1067 1068 1068 1066 + 1069 1069 = 5. Trouble Shooting = 1070 1070 1069 + 1071 1071 == 5.1 Why I can't join TTN in US915 / AU915 bands? == 1072 1072 1072 + 1073 1073 It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 1074 1074 1075 1075 1076 + 1076 1076 == 5.2 AT Command input doesn't work == 1077 1077 1079 + 1078 1078 ((( 1079 1079 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1080 1080 ))) 1081 1081 1082 1082 1085 + 1083 1083 == 5.3 Device rejoin in at the second uplink packet == 1084 1084 1088 + 1085 1085 (% style="color:#4f81bd" %)**Issue describe as below:** 1086 1086 1087 1087 [[image:1654500909990-784.png]] ... ... @@ -1096,11 +1096,14 @@ 1096 1096 1097 1097 (% style="color:#4f81bd" %)**Solution: ** 1098 1098 1103 +((( 1099 1099 All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below: 1105 +))) 1100 1100 1101 1101 [[image:1654500929571-736.png||height="458" width="832"]] 1102 1102 1103 1103 1110 + 1104 1104 = 6. Order Info = 1105 1105 1106 1106 ... ... @@ -1166,5 +1166,8 @@ 1166 1166 1167 1167 = 8. Support = 1168 1168 1176 + 1169 1169 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1170 1170 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1179 + 1180 +
- image-20221008135912-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.9 KB - Content
- image-20221008140228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.3 KB - Content