From version < 42.1 >
edited by Xiaoling
on 2022/07/08 13:45
To version < 40.3 >
edited by Xiaoling
on 2022/06/30 10:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -314,7 +314,6 @@
314 314  )))
315 315  
316 316  
317 -
318 318  == 2.4 Uplink Interval ==
319 319  
320 320  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
... ... @@ -323,13 +323,13 @@
323 323  
324 324  == 2.5 Downlink Payload ==
325 325  
326 -By default, LSE01 prints the downlink payload to console port.
325 +By default, LSE50 prints the downlink payload to console port.
327 327  
328 328  [[image:image-20220606165544-8.png]]
329 329  
330 330  
331 331  (((
332 -(% style="color:blue" %)**Examples:**
331 +**Examples:**
333 333  )))
334 334  
335 335  (((
... ... @@ -337,11 +337,11 @@
337 337  )))
338 338  
339 339  * (((
340 -(% style="color:blue" %)**Set TDC**
339 +**Set TDC**
341 341  )))
342 342  
343 343  (((
344 -If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
343 +If the payload=0100003C, it means set the END Nodes TDC to 0x00003C=60(S), while type code is 01.
345 345  )))
346 346  
347 347  (((
... ... @@ -357,7 +357,7 @@
357 357  )))
358 358  
359 359  * (((
360 -(% style="color:blue" %)**Reset**
359 +**Reset**
361 361  )))
362 362  
363 363  (((
... ... @@ -365,7 +365,7 @@
365 365  )))
366 366  
367 367  
368 -* (% style="color:blue" %)**CFM**
367 +* **CFM**
369 369  
370 370  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
371 371  
... ... @@ -698,7 +698,6 @@
698 698  
699 699  
700 700  
701 -
702 702  == 2.9 Installation in Soil ==
703 703  
704 704  **Measurement the soil surface**
... ... @@ -803,11 +803,11 @@
803 803  )))
804 804  
805 805  (((
806 -You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
804 +You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
807 807  )))
808 808  
809 809  (((
810 -The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
808 +The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user cant find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
811 811  )))
812 812  
813 813  
... ... @@ -1022,15 +1022,15 @@
1022 1022  
1023 1023  = 5. Trouble Shooting =
1024 1024  
1025 -== 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1023 +== 5.1 ​Why I cant join TTN in US915 / AU915 bands? ==
1026 1026  
1027 -It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
1025 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.
1028 1028  
1029 1029  
1030 -== 5.2 AT Command input doesn't work ==
1028 +== 5.2 AT Command input doesnt work ==
1031 1031  
1032 1032  (((
1033 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1031 +In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1034 1034  )))
1035 1035  
1036 1036  
... ... @@ -1080,8 +1080,6 @@
1080 1080  (% class="wikigeneratedid" %)
1081 1081  (((
1082 1082  
1083 -
1084 -
1085 1085  )))
1086 1086  
1087 1087  = 7. Packing Info =
... ... @@ -1114,7 +1114,6 @@
1114 1114  * (((
1115 1115  Weight / pcs : g
1116 1116  
1117 -
1118 1118  
1119 1119  )))
1120 1120  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0