311 311  )))
312 312  
313 313  
314 +
314 314  == 2.4 Uplink Interval ==
315 315  
316 316  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
... ... @@ -319,7 +319,7 @@
319 319  
320 320  == 2.5 Downlink Payload ==
321 321  
322 -By default, LSE50 prints the downlink payload to console port.
323 +By default, LSE01 prints the downlink payload to console port.
323 323  
324 324  [[image:image-20220606165544-8.png]]
325 325  
... ... @@ -337,7 +337,7 @@
337 337  )))
338 338  
339 339  (((
340 -If the payload=0100003C, it means set the END Nodes TDC to 0x00003C=60(S), while type code is 01.
341 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
341 341  )))
342 342  
343 343  (((
... ... @@ -798,11 +798,11 @@
798 798  )))
799 799  
800 800  (((
801 -You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
802 +You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
802 802  )))
803 803  
804 804  (((
805 -The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user cant find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
806 +The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
806 806  )))
807 807  
808 808  
... ... @@ -833,13 +833,13 @@
833 833  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]: [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]
834 834  
835 835  
836 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>? **(%%) : Help on <CMD>
837 +(% style="background-color:#dcdcdc" %)**AT+<CMD>? **(%%) : Help on <CMD>
837 837  
838 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD> **(%%) : Run <CMD>
839 +(% style="background-color:#dcdcdc" %)**AT+<CMD> **(%%) : Run <CMD>
839 839  
840 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>=<value>**(%%) : Set the value
841 +(% style="background-color:#dcdcdc" %)**AT+<CMD>=<value>**(%%)  : Set the value
841 841  
842 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>=?**(%%)  : Get the value
843 +(% style="background-color:#dcdcdc" %)**AT+<CMD>=?**(%%)  : Get the value
843 843  
844 844  
845 845  (% style="color:#037691" %)**General Commands**(%%)      
... ... @@ -1019,7 +1019,7 @@
1019 1019  
1020 1020  == 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1021 1021  
1022 -It is due to channel mapping. Please see the [[Eight Channel Mode>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/#H7.19EightChannelMode||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.
1023 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
1023 1023  
1024 1024  
1025 1025  == 5.2 AT Command input doesn't work ==
... ... @@ -1075,6 +1075,8 @@
1075 1075  (% class="wikigeneratedid" %)
1076 1076  (((
1077 1077  
1079 +
1080 +
1078 1078  )))
1079 1079  
1080 1080  = 7. Packing Info =
... ... @@ -1107,6 +1107,7 @@
1107 1107  * (((
1108 1108  Weight / pcs : g
1109 1109  
1113 +
1110 1110  
1111 1111  )))