Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -22,11 +22,11 @@ 22 22 23 23 = 1. Introduction = 24 24 25 + 25 25 == 1.1 What is LoRaWAN Soil Moisture & EC Sensor == 26 26 27 -((( 28 - 29 29 29 +((( 30 30 The Dragino LSE01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil Moisture & EC Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type. 31 31 ))) 32 32 ... ... @@ -56,6 +56,7 @@ 56 56 57 57 == 1.2 Features == 58 58 59 + 59 59 * LoRaWAN 1.0.3 Class A 60 60 * Ultra low power consumption 61 61 * Monitor Soil Moisture ... ... @@ -68,9 +68,9 @@ 68 68 * IP66 Waterproof Enclosure 69 69 * 4000mAh or 8500mAh Battery for long term use 70 70 71 - 72 72 == 1.3 Specification == 73 73 74 + 74 74 Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. 75 75 76 76 [[image:image-20220606162220-5.png]] ... ... @@ -77,16 +77,30 @@ 77 77 78 78 79 79 80 -== 1.4Applications==81 +== 1.4 Dimension == 81 81 82 -* Smart Agriculture 83 83 84 -(% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %) 85 - 84 +**Main Device Dimension:** 86 86 87 - ==1.5FirmwareChangelog==86 +See LSN50v2 from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/ >>https://www.dragino.com/downloads/index.php?dir=LSN50-LoRaST/Mechanical_Drawing/]] 88 88 88 +[[image:image-20221008140228-2.png||height="358" width="571"]] 89 89 90 + 91 +**Probe Dimension** 92 + 93 +[[image:image-20221008135912-1.png]] 94 + 95 + 96 + 97 +== 1.5 Applications == 98 + 99 + 100 +* Smart Agriculture 101 + 102 +== 1.6 Firmware Change log == 103 + 104 + 90 90 **LSE01 v1.0 :** Release 91 91 92 92 ... ... @@ -93,14 +93,16 @@ 93 93 94 94 = 2. Configure LSE01 to connect to LoRaWAN network = 95 95 111 + 96 96 == 2.1 How it works == 97 97 114 + 98 98 ((( 99 99 The LSE01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSE0150. It will automatically join the network via OTAA and start to send the sensor value 100 100 ))) 101 101 102 102 ((( 103 -In case you can ’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]].120 +In case you can't set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]]. 104 104 ))) 105 105 106 106 ... ... @@ -107,6 +107,7 @@ 107 107 108 108 == 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 109 109 127 + 110 110 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example. 111 111 112 112 ... ... @@ -122,6 +122,7 @@ 122 122 123 123 [[image:image-20220606163732-6.jpeg]] 124 124 143 + 125 125 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: 126 126 127 127 **Add APP EUI in the application** ... ... @@ -156,6 +156,7 @@ 156 156 157 157 === 2.3.1 MOD~=0(Default Mode) === 158 158 178 + 159 159 LSE01 will uplink payload via LoRaWAN with below payload format: 160 160 161 161 ((( ... ... @@ -162,46 +162,40 @@ 162 162 Uplink payload includes in total 11 bytes. 163 163 ))) 164 164 165 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 166 -|((( 167 -**Size** 168 - 169 -**(bytes)** 185 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 186 +|=(% scope="row" %)((( 187 +**Size(bytes)** 170 170 )))|**2**|**2**|**2**|**2**|**2**|**1** 171 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 189 +|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 172 172 Temperature 173 - 174 174 (Reserve, Ignore now) 175 175 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|((( 176 -MOD & Digital Interrupt 177 - 178 -(Optional) 193 +MOD & Digital Interrupt(Optional) 179 179 ))) 180 180 181 181 197 + 182 182 === 2.3.2 MOD~=1(Original value) === 183 183 200 + 184 184 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 185 185 186 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %) 187 -|((( 188 -**Size** 189 - 190 -**(bytes)** 203 +(% border="1" cellspacing="5" style="background-color:#ffffcc; width:500px" %) 204 +|=(% scope="row" %)((( 205 +**Size(bytes)** 191 191 )))|**2**|**2**|**2**|**2**|**2**|**1** 192 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 207 +|=**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 193 193 Temperature 194 - 195 195 (Reserve, Ignore now) 196 196 )))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 197 -MOD & Digital Interrupt 198 - 199 -(Optional) 211 +MOD & Digital Interrupt(Optional) 200 200 ))) 201 201 202 202 215 + 203 203 === 2.3.3 Battery Info === 204 204 218 + 205 205 ((( 206 206 Check the battery voltage for LSE01. 207 207 ))) ... ... @@ -218,6 +218,7 @@ 218 218 219 219 === 2.3.4 Soil Moisture === 220 220 235 + 221 221 ((( 222 222 Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil. 223 223 ))) ... ... @@ -238,6 +238,7 @@ 238 238 239 239 === 2.3.5 Soil Temperature === 240 240 256 + 241 241 ((( 242 242 Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is 243 243 ))) ... ... @@ -258,6 +258,7 @@ 258 258 259 259 === 2.3.6 Soil Conductivity (EC) === 260 260 277 + 261 261 ((( 262 262 Obtain (% style="color:#4f81bd" %)**__soluble salt concentration__**(%%) in soil or (% style="color:#4f81bd" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:#4f81bd" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000). 263 263 ))) ... ... @@ -280,6 +280,7 @@ 280 280 281 281 === 2.3.7 MOD === 282 282 300 + 283 283 Firmware version at least v2.1 supports changing mode. 284 284 285 285 For example, bytes[10]=90 ... ... @@ -297,6 +297,7 @@ 297 297 298 298 === 2.3.8 Decode payload in The Things Network === 299 299 318 + 300 300 While using TTN network, you can add the payload format to decode the payload. 301 301 302 302 ... ... @@ -307,12 +307,14 @@ 307 307 ))) 308 308 309 309 ((( 310 -LSE01 TTN Payload Decoder: www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]]329 +LSE01 TTN Payload Decoder: [[https:~~/~~/github.com/dragino/dragino-end-node-decoder>>https://github.com/dragino/dragino-end-node-decoder]] 311 311 ))) 312 312 313 313 333 + 314 314 == 2.4 Uplink Interval == 315 315 336 + 316 316 The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 317 317 318 318 ... ... @@ -319,8 +319,9 @@ 319 319 320 320 == 2.5 Downlink Payload == 321 321 322 -By default, LSE50 prints the downlink payload to console port. 323 323 344 +By default, LSE01 prints the downlink payload to console port. 345 + 324 324 [[image:image-20220606165544-8.png]] 325 325 326 326 ... ... @@ -337,7 +337,7 @@ 337 337 ))) 338 338 339 339 ((( 340 -If the payload=0100003C, it means set the END Node ’s TDC to 0x00003C=60(S), while type code is 01.362 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 341 341 ))) 342 342 343 343 ((( ... ... @@ -369,6 +369,7 @@ 369 369 370 370 == 2.6 Show Data in DataCake IoT Server == 371 371 394 + 372 372 ((( 373 373 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 374 374 ))) ... ... @@ -408,11 +408,14 @@ 408 408 409 409 == 2.7 Frequency Plans == 410 410 434 + 411 411 The LSE01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 412 412 413 413 438 + 414 414 === 2.7.1 EU863-870 (EU868) === 415 415 441 + 416 416 (% style="color:#037691" %)** Uplink:** 417 417 418 418 868.1 - SF7BW125 to SF12BW125 ... ... @@ -444,6 +444,7 @@ 444 444 445 445 === 2.7.2 US902-928(US915) === 446 446 473 + 447 447 Used in USA, Canada and South America. Default use CHE=2 448 448 449 449 (% style="color:#037691" %)**Uplink:** ... ... @@ -489,6 +489,7 @@ 489 489 490 490 === 2.7.3 CN470-510 (CN470) === 491 491 519 + 492 492 Used in China, Default use CHE=1 493 493 494 494 (% style="color:#037691" %)**Uplink:** ... ... @@ -534,6 +534,7 @@ 534 534 535 535 === 2.7.4 AU915-928(AU915) === 536 536 565 + 537 537 Default use CHE=2 538 538 539 539 (% style="color:#037691" %)**Uplink:** ... ... @@ -579,6 +579,7 @@ 579 579 580 580 === 2.7.5 AS920-923 & AS923-925 (AS923) === 581 581 611 + 582 582 (% style="color:#037691" %)**Default Uplink channel:** 583 583 584 584 923.2 - SF7BW125 to SF10BW125 ... ... @@ -630,6 +630,7 @@ 630 630 631 631 === 2.7.6 KR920-923 (KR920) === 632 632 663 + 633 633 Default channel: 634 634 635 635 922.1 - SF7BW125 to SF12BW125 ... ... @@ -666,6 +666,7 @@ 666 666 667 667 === 2.7.7 IN865-867 (IN865) === 668 668 700 + 669 669 (% style="color:#037691" %)** Uplink:** 670 670 671 671 865.0625 - SF7BW125 to SF12BW125 ... ... @@ -686,6 +686,7 @@ 686 686 687 687 == 2.8 LED Indicator == 688 688 721 + 689 689 The LSE01 has an internal LED which is to show the status of different state. 690 690 691 691 * Blink once when device power on. ... ... @@ -696,11 +696,13 @@ 696 696 697 697 == 2.9 Installation in Soil == 698 698 732 + 699 699 **Measurement the soil surface** 700 700 701 701 702 702 [[image:1654506634463-199.png]] 703 703 738 + 704 704 ((( 705 705 ((( 706 706 Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting. ... ... @@ -711,6 +711,7 @@ 711 711 712 712 [[image:1654506665940-119.png]] 713 713 749 + 714 714 ((( 715 715 Dig a hole with diameter > 20CM. 716 716 ))) ... ... @@ -720,14 +720,12 @@ 720 720 ))) 721 721 722 722 759 + 723 723 == 2.10 Firmware Change Log == 724 724 725 -((( 726 -**Firmware download link:** 727 -))) 728 728 729 729 ((( 730 -[[http:~~/~~/www.dr agino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]764 +**Firmware download link: **[[https:~~/~~/www.dropbox.com/sh/8ixj7zgt477ip51/AADLrib9Oe6IuOpPF5o1GPf9a?dl=0>>https://www.dropbox.com/sh/8ixj7zgt477ip51/AADLrib9Oe6IuOpPF5o1GPf9a?dl=0]] 731 731 ))) 732 732 733 733 ((( ... ... @@ -751,10 +751,13 @@ 751 751 ))) 752 752 753 753 788 + 754 754 == 2.11 Battery Analysis == 755 755 791 + 756 756 === 2.11.1 Battery Type === 757 757 794 + 758 758 ((( 759 759 The LSE01 battery is a combination of a 4000mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 760 760 ))) ... ... @@ -785,6 +785,7 @@ 785 785 786 786 === 2.11.2 Battery Note === 787 787 825 + 788 788 ((( 789 789 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 790 790 ))) ... ... @@ -793,16 +793,17 @@ 793 793 794 794 === 2.11.3 Replace the battery === 795 795 834 + 796 796 ((( 797 797 If Battery is lower than 2.7v, user should replace the battery of LSE01. 798 798 ))) 799 799 800 800 ((( 801 -You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won ’t be voltage drop between battery and main board.840 +You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 802 802 ))) 803 803 804 804 ((( 805 -The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can ’t find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)844 +The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 806 806 ))) 807 807 808 808 ... ... @@ -809,11 +809,13 @@ 809 809 810 810 = 3. Using the AT Commands = 811 811 851 + 812 812 == 3.1 Access AT Commands == 813 813 814 814 815 815 LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below. 816 816 857 + 817 817 [[image:1654501986557-872.png||height="391" width="800"]] 818 818 819 819 ... ... @@ -830,16 +830,16 @@ 830 830 [[image:1654502050864-459.png||height="564" width="806"]] 831 831 832 832 833 -Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]] : [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]874 +Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]. 834 834 835 835 836 -(% style="background-color:#dcdcdc" %)**AT+<CMD> =?AT+<CMD>?**(%%) : Help on <CMD>877 +(% style="background-color:#dcdcdc" %)**AT+<CMD>? **(%%) : Help on <CMD> 837 837 838 -(% style="background-color:#dcdcdc" %)**AT+<CMD> =?AT+<CMD>**(%%) : Run <CMD>879 +(% style="background-color:#dcdcdc" %)**AT+<CMD> **(%%) : Run <CMD> 839 839 840 -(% style="background-color:#dcdcdc" %)**AT+<CMD>= ?AT+<CMD>=<value>**(%%)881 +(% style="background-color:#dcdcdc" %)**AT+<CMD>=<value>**(%%) : Set the value 841 841 842 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=? AT+<CMD>=?**(%%)883 +(% style="background-color:#dcdcdc" %)**AT+<CMD>=?**(%%) : Get the value 843 843 844 844 845 845 (% style="color:#037691" %)**General Commands**(%%) ... ... @@ -938,10 +938,13 @@ 938 938 (% style="background-color:#dcdcdc" %)**AT+CHE**(%%) : Get or Set eight channels mode, Only for US915, AU915, CN470 939 939 940 940 982 + 941 941 = 4. FAQ = 942 942 985 + 943 943 == 4.1 How to change the LoRa Frequency Bands/Region? == 944 944 988 + 945 945 ((( 946 946 You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 947 947 When downloading the images, choose the required image file for download. ... ... @@ -1010,27 +1010,38 @@ 1010 1010 [[image:image-20220606154825-4.png]] 1011 1011 1012 1012 1057 + 1013 1013 == 4.2 Can I calibrate LSE01 to different soil types? == 1014 1014 1060 + 1061 +((( 1015 1015 LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1063 +))) 1016 1016 1017 1017 1066 + 1018 1018 = 5. Trouble Shooting = 1019 1019 1020 -== 5.1 Why I can’t join TTN in US915 / AU915 bands? == 1021 1021 1022 - Itisduetochannel mapping. Please seethe[[Eight Channel Mode>>doc:Main.LoRaWANCommunicationDebug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]sectionabove for details.1070 +== 5.1 Why I can't join TTN in US915 / AU915 bands? == 1023 1023 1024 1024 1025 - ==5.2AT Command inputdoesn’twork==1073 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 1026 1026 1075 + 1076 + 1077 +== 5.2 AT Command input doesn't work == 1078 + 1079 + 1027 1027 ((( 1028 -In the case if user can see the console output but can ’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.1081 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1029 1029 ))) 1030 1030 1031 1031 1085 + 1032 1032 == 5.3 Device rejoin in at the second uplink packet == 1033 1033 1088 + 1034 1034 (% style="color:#4f81bd" %)**Issue describe as below:** 1035 1035 1036 1036 [[image:1654500909990-784.png]] ... ... @@ -1045,11 +1045,14 @@ 1045 1045 1046 1046 (% style="color:#4f81bd" %)**Solution: ** 1047 1047 1103 +((( 1048 1048 All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below: 1105 +))) 1049 1049 1050 1050 [[image:1654500929571-736.png||height="458" width="832"]] 1051 1051 1052 1052 1110 + 1053 1053 = 6. Order Info = 1054 1054 1055 1055 ... ... @@ -1075,6 +1075,8 @@ 1075 1075 (% class="wikigeneratedid" %) 1076 1076 ((( 1077 1077 1136 + 1137 + 1078 1078 ))) 1079 1079 1080 1080 = 7. Packing Info = ... ... @@ -1107,10 +1107,14 @@ 1107 1107 * ((( 1108 1108 Weight / pcs : g 1109 1109 1170 + 1110 1110 1111 1111 ))) 1112 1112 1113 1113 = 8. Support = 1114 1114 1176 + 1115 1115 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1116 1116 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1179 + 1180 +
- image-20221008135912-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +65.9 KB - Content
- image-20221008140228-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +37.3 KB - Content