Changes for page LSE01-LoRaWAN Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/08/02 16:47
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -179,6 +179,8 @@ 179 179 (Optional) 180 180 ))) 181 181 182 + 183 + 182 182 === 2.3.2 MOD~=1(Original value) === 183 183 184 184 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). ... ... @@ -199,6 +199,8 @@ 199 199 (Optional) 200 200 ))) 201 201 204 + 205 + 202 202 === 2.3.3 Battery Info === 203 203 204 204 ((( ... ... @@ -310,6 +310,7 @@ 310 310 ))) 311 311 312 312 317 + 313 313 == 2.4 Uplink Interval == 314 314 315 315 The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] ... ... @@ -318,13 +318,13 @@ 318 318 319 319 == 2.5 Downlink Payload == 320 320 321 -By default, LSE 50 prints the downlink payload to console port.326 +By default, LSE01 prints the downlink payload to console port. 322 322 323 323 [[image:image-20220606165544-8.png]] 324 324 325 325 326 326 ((( 327 -**Examples:** 332 +(% style="color:blue" %)**Examples:** 328 328 ))) 329 329 330 330 ((( ... ... @@ -332,11 +332,11 @@ 332 332 ))) 333 333 334 334 * ((( 335 -**Set TDC** 340 +(% style="color:blue" %)**Set TDC** 336 336 ))) 337 337 338 338 ((( 339 -If the payload=0100003C, it means set the END Node ’s TDC to 0x00003C=60(S), while type code is 01.344 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 340 340 ))) 341 341 342 342 ((( ... ... @@ -352,7 +352,7 @@ 352 352 ))) 353 353 354 354 * ((( 355 -**Reset** 360 +(% style="color:blue" %)**Reset** 356 356 ))) 357 357 358 358 ((( ... ... @@ -360,7 +360,7 @@ 360 360 ))) 361 361 362 362 363 -* **CFM** 368 +* (% style="color:blue" %)**CFM** 364 364 365 365 Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0 366 366 ... ... @@ -693,6 +693,7 @@ 693 693 694 694 695 695 701 + 696 696 == 2.9 Installation in Soil == 697 697 698 698 **Measurement the soil surface** ... ... @@ -797,11 +797,11 @@ 797 797 ))) 798 798 799 799 ((( 800 -You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won ’t be voltage drop between battery and main board.806 +You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 801 801 ))) 802 802 803 803 ((( 804 -The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can ’t find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)810 +The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 805 805 ))) 806 806 807 807 ... ... @@ -1016,15 +1016,15 @@ 1016 1016 1017 1017 = 5. Trouble Shooting = 1018 1018 1019 -== 5.1 Why I can ’t join TTN in US915 / AU915 bands? ==1025 +== 5.1 Why I can't join TTN in US915 / AU915 bands? == 1020 1020 1021 -It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main. LoRaWANCommunication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.1027 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details. 1022 1022 1023 1023 1024 -== 5.2 AT Command input doesn ’t work ==1030 +== 5.2 AT Command input doesn't work == 1025 1025 1026 1026 ((( 1027 -In the case if user can see the console output but can ’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.1033 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1028 1028 ))) 1029 1029 1030 1030 ... ... @@ -1074,6 +1074,8 @@ 1074 1074 (% class="wikigeneratedid" %) 1075 1075 ((( 1076 1076 1083 + 1084 + 1077 1077 ))) 1078 1078 1079 1079 = 7. Packing Info = ... ... @@ -1106,6 +1106,7 @@ 1106 1106 * ((( 1107 1107 Weight / pcs : g 1108 1108 1117 + 1109 1109 1110 1110 ))) 1111 1111