... ... @@ -68,6 +68,7 @@
68 68  * IP66 Waterproof Enclosure
69 69  * 4000mAh or 8500mAh Battery for long term use
70 70  
71 +
71 71  == 1.3 Specification ==
72 72  
73 73  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -177,6 +177,7 @@
177 177  (Optional)
178 178  )))
179 179  
181 +
180 180  === 2.3.2 MOD~=1(Original value) ===
181 181  
182 182  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -197,6 +197,7 @@
197 197  (Optional)
198 198  )))
199 199  
202 +
200 200  === 2.3.3 Battery Info ===
201 201  
202 202  (((
... ... @@ -308,6 +308,7 @@
308 308  )))
309 309  
310 310  
314 +
311 311  == 2.4 Uplink Interval ==
312 312  
313 313  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
... ... @@ -316,13 +316,13 @@
316 316  
317 317  == 2.5 Downlink Payload ==
318 318  
319 -By default, LSE50 prints the downlink payload to console port.
323 +By default, LSE01 prints the downlink payload to console port.
320 320  
321 321  [[image:image-20220606165544-8.png]]
322 322  
323 323  
324 324  (((
325 -**Examples:**
329 +(% style="color:blue" %)**Examples:**
326 326  )))
327 327  
328 328  (((
... ... @@ -330,11 +330,11 @@
330 330  )))
331 331  
332 332  * (((
333 -**Set TDC**
337 +(% style="color:blue" %)**Set TDC**
334 334  )))
335 335  
336 336  (((
337 -If the payload=0100003C, it means set the END Nodes TDC to 0x00003C=60(S), while type code is 01.
341 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
338 338  )))
339 339  
340 340  (((
... ... @@ -350,7 +350,7 @@
350 350  )))
351 351  
352 352  * (((
353 -**Reset**
357 +(% style="color:blue" %)**Reset**
354 354  )))
355 355  
356 356  (((
... ... @@ -358,7 +358,7 @@
358 358  )))
359 359  
360 360  
361 -* **CFM**
365 +* (% style="color:blue" %)**CFM**
362 362  
363 363  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
364 364  
... ... @@ -691,7 +691,6 @@
691 691  
692 692  
693 693  
694 -
695 695  == 2.9 Installation in Soil ==
696 696  
697 697  **Measurement the soil surface**
... ... @@ -796,11 +796,11 @@
796 796  )))
797 797  
798 798  (((
799 -You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
802 +You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
800 800  )))
801 801  
802 802  (((
803 -The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user cant find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
806 +The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
804 804  )))
805 805  
806 806  
... ... @@ -831,13 +831,13 @@
831 831  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]: [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]
832 832  
833 833  
834 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>? **(%%) : Help on <CMD>
837 +(% style="background-color:#dcdcdc" %)**AT+<CMD>? **(%%) : Help on <CMD>
835 835  
836 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD> **(%%) : Run <CMD>
839 +(% style="background-color:#dcdcdc" %)**AT+<CMD> **(%%) : Run <CMD>
837 837  
838 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>=<value>**(%%) : Set the value
841 +(% style="background-color:#dcdcdc" %)**AT+<CMD>=<value>**(%%)  : Set the value
839 839  
840 -(% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>=?**(%%)  : Get the value
843 +(% style="background-color:#dcdcdc" %)**AT+<CMD>=?**(%%)  : Get the value
841 841  
842 842  
843 843  (% style="color:#037691" %)**General Commands**(%%)      
... ... @@ -1015,15 +1015,15 @@
1015 1015  
1016 1016  = 5. Trouble Shooting =
1017 1017  
1018 -== 5.1 ​Why I cant join TTN in US915 / AU915 bands? ==
1021 +== 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1019 1019  
1020 -It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.
1023 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
1021 1021  
1022 1022  
1023 -== 5.2 AT Command input doesnt work ==
1026 +== 5.2 AT Command input doesn't work ==
1024 1024  
1025 1025  (((
1026 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1029 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1027 1027  )))
1028 1028  
1029 1029  
... ... @@ -1073,6 +1073,8 @@
1073 1073  (% class="wikigeneratedid" %)
1074 1074  (((
1075 1075  
1079 +
1080 +
1076 1076  )))
1077 1077  
1078 1078  = 7. Packing Info =
... ... @@ -1105,6 +1105,7 @@
1105 1105  * (((
1106 1106  Weight / pcs : g
1107 1107  
1113 +
1108 1108  
1109 1109  )))