<
From version < 39.1 >
edited by Xiaoling
on 2022/06/25 16:34
To version < 42.1 >
edited by Xiaoling
on 2022/07/08 13:45
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -69,6 +69,7 @@
69 69  * 4000mAh or 8500mAh Battery for long term use
70 70  
71 71  
72 +
72 72  == 1.3 Specification ==
73 73  
74 74  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -179,6 +179,7 @@
179 179  )))
180 180  
181 181  
183 +
182 182  === 2.3.2 MOD~=1(Original value) ===
183 183  
184 184  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -200,6 +200,7 @@
200 200  )))
201 201  
202 202  
205 +
203 203  === 2.3.3 Battery Info ===
204 204  
205 205  (((
... ... @@ -311,6 +311,7 @@
311 311  )))
312 312  
313 313  
317 +
314 314  == 2.4 Uplink Interval ==
315 315  
316 316  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
... ... @@ -319,13 +319,13 @@
319 319  
320 320  == 2.5 Downlink Payload ==
321 321  
322 -By default, LSE50 prints the downlink payload to console port.
326 +By default, LSE01 prints the downlink payload to console port.
323 323  
324 324  [[image:image-20220606165544-8.png]]
325 325  
326 326  
327 327  (((
328 -**Examples:**
332 +(% style="color:blue" %)**Examples:**
329 329  )))
330 330  
331 331  (((
... ... @@ -333,11 +333,11 @@
333 333  )))
334 334  
335 335  * (((
336 -**Set TDC**
340 +(% style="color:blue" %)**Set TDC**
337 337  )))
338 338  
339 339  (((
340 -If the payload=0100003C, it means set the END Nodes TDC to 0x00003C=60(S), while type code is 01.
344 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
341 341  )))
342 342  
343 343  (((
... ... @@ -353,7 +353,7 @@
353 353  )))
354 354  
355 355  * (((
356 -**Reset**
360 +(% style="color:blue" %)**Reset**
357 357  )))
358 358  
359 359  (((
... ... @@ -361,7 +361,7 @@
361 361  )))
362 362  
363 363  
364 -* **CFM**
368 +* (% style="color:blue" %)**CFM**
365 365  
366 366  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
367 367  
... ... @@ -695,7 +695,6 @@
695 695  
696 696  
697 697  
698 -
699 699  == 2.9 Installation in Soil ==
700 700  
701 701  **Measurement the soil surface**
... ... @@ -800,11 +800,11 @@
800 800  )))
801 801  
802 802  (((
803 -You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there wont be voltage drop between battery and main board.
806 +You can change the battery in the LSE01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
804 804  )))
805 805  
806 806  (((
807 -The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user cant find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
810 +The default battery pack of LSE01 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
808 808  )))
809 809  
810 810  
... ... @@ -1012,18 +1012,22 @@
1012 1012  [[image:image-20220606154825-4.png]]
1013 1013  
1014 1014  
1018 +== 4.2 ​Can I calibrate LSE01 to different soil types? ==
1015 1015  
1020 +LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
1021 +
1022 +
1016 1016  = 5. Trouble Shooting =
1017 1017  
1018 -== 5.1 ​Why I cant join TTN in US915 / AU915 bands? ==
1025 +== 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1019 1019  
1020 -It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.
1027 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
1021 1021  
1022 1022  
1023 -== 5.2 AT Command input doesnt work ==
1030 +== 5.2 AT Command input doesn't work ==
1024 1024  
1025 1025  (((
1026 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1033 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1027 1027  )))
1028 1028  
1029 1029  
... ... @@ -1073,6 +1073,8 @@
1073 1073  (% class="wikigeneratedid" %)
1074 1074  (((
1075 1075  
1083 +
1084 +
1076 1076  )))
1077 1077  
1078 1078  = 7. Packing Info =
... ... @@ -1105,6 +1105,7 @@
1105 1105  * (((
1106 1106  Weight / pcs : g
1107 1107  
1117 +
1108 1108  
1109 1109  )))
1110 1110  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0