Changes for page LHT65N -- Manual do sensor de temperatura e umidade LoRaWAN
Last modified by Xiaoling on 2023/07/18 10:12
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -905,16 +905,16 @@ 905 905 906 906 Explique: 907 907 908 -* (% style="color:#037691" %)**Parâmetro 1: **(%%) Set WorkingModeto**Mode3**909 -* (% style="color:#037691" %)**Parâmetro 2:**(%%) Set the temperature samplingmode to**1**(1:DS18B20;2:TMP117;3:****InternalGXHT30).910 -* (% style="color:#037691" %)**Parâmetro 3: **(%%) SamplingIntervalis**60**s.911 -* (% style="color:#037691" %)**Parâmetro 4: **(%%) Whenthereis **20** samplingdats,Devicewillsendthese dataviaone uplink. (maxvalueis60,means max 60samplinginoneuplink)912 -* (% style="color:#037691" %)**Parâmetro 5: & Parâmetro 6: **(%%) Temperaturealarmrangeis **-16** to **32**°C,913 -* (% style="color:#037691" %)**Parâmetro 7:**(%%) 1 to enable temperaturealarm,**0** todisablethe temperaturealarm.Ifalarmisnabled,adatawill besentimmediatelyiftemperate exceedstheAlarmrange.908 +* (% style="color:#037691" %)**Parâmetro 1: **(%%)Definir o Modo de Trabalho para o Modo 3 909 +* (% style="color:#037691" %)**Parâmetro 2:**(%%) Ajuste o modo de amostragem de temperatura para 1 (1: DS18B20; 2: TMP117;3: GXHT30 interno). 910 +* (% style="color:#037691" %)**Parâmetro 3: **(%%)Intervalo de amostragem é de 60. 911 +* (% style="color:#037691" %)**Parâmetro 4: **(%%)Quando houver 20 datas de amostragem, o dispositivo enviará esses dados por meio de um uplink. (valor máximo é 60, significa amostragem máxima 60 em um uplink) 912 +* (% style="color:#037691" %)**Parâmetro 5: & Parâmetro 6: **(%%)A escala do alarme da temperatura é -16 a 32°C, 913 +* (% style="color:#037691" %)**Parâmetro 7:**(%%) 1 para ativar o alarme de temperatura, 0 para desativar o alarme de temperatura. Se o alarme estiver ativado, um dado será enviado imediatamente se o temperamento exceder o intervalo de alarme. 914 914 915 -(% style="color:#4f81bd" %)**Downlink Command:**915 +(% style="color:#4f81bd" %)**Comando Downlink:** 916 916 917 -**Ex ample:**A50301003C14FFF0002001917 +**Exemplo: A50301003C14FFF0002001** 918 918 919 919 MOD=03 920 920 ... ... @@ -922,7 +922,7 @@ 922 922 923 923 CITEMP=003C(S) 924 924 925 - Totalnumberofacquisitions=14925 +Número total de aquisições=14 926 926 927 927 TEMPlow=FFF0 928 928 ... ... @@ -931,49 +931,49 @@ 931 931 ARTEMP=01 932 932 933 933 934 -** Uplinkpayload(Fport=3)**934 +**Carga útil de ligação ascendente (Fport=3)** 935 935 936 -**Ex ample:**01**0992**//0A41//**09C4**936 +**Exemplo: CBEA0109920A4109C4** 937 937 938 938 BatV=CBEA 939 939 940 940 TEMP=DS18B20 941 941 942 -Temp1=0992 ~/~/ 24 .50℃942 +Temp1=0992 ~/~/ 24,50℃ 943 943 944 -Temp2=0A41 ~/~/ 26 .25℃944 +Temp2=0A41 ~/~/ 26,25℃ 945 945 946 -Temp3=09C4 .00℃946 +Temp3=09C4 ~/~/ 25,00℃ 947 947 948 -(% style="color:red" %)**Not e:This uplinkwillautomatically selectthe appropriateDRaccordingtothedata length**948 +(% style="color:red" %)**Nota: Este uplink selecionará automaticamente o DR apropriado de acordo com o comprimento dos dados** 949 949 950 -(% style="color:red" %)** In this mode,the temperatureresolutionofds18b20is0.25℃tosavepower consumption**950 +(% style="color:red" %)** Neste modo, a resolução da temperatura de ds18b20 é 0,25℃ para economizar o consumo de energia** 951 951 ))) 952 952 953 953 954 -=== 2.7.2 ALARM MODE(Beforev1.3.1firmware) ===954 +=== 2.7.2 MODO DE ALARMA (Antes do firmware v1.3.1) === 955 955 956 956 957 957 (% class="box infomessage" %) 958 958 ((( 959 959 ((( 960 -**AT+WMOD=1**: nable/disable alarmmode. (0: Disabled, 1:EnabledTemperature Alarmforonboard temperaturesensor)960 +**AT+WMOD=1**: EActivar/desactivar o modo de alarme. (0: Desativado, 1: Alarme de temperatura ativado para sensor de temperatura a bordo) 961 961 ))) 962 962 963 963 ((( 964 -**AT+CITEMP=1**: Theintervalbetweencheckingthealarmtemperature. (Inminutes)964 +**AT+CITEMP=1**: O intervalo entre a verificação da temperatura do alarme. (Em minutos) 965 965 ))) 966 966 967 967 ((( 968 -**AT+ARTEMP**: Getsorsetsthe alarmrange oftheinternaltemperaturesensor968 +**AT+ARTEMP**: Obtém ou define a faixa de alarme do sensor de temperatura interno 969 969 ))) 970 970 971 971 ((( 972 -(% _mstmutation="1" %)**AT+ARTEMP=? **(%%): Getsthe alarmrange oftheinternaltemperaturesensor(% style="display:none" %)972 +(% _mstmutation="1" %)**AT+ARTEMP=? **(%%): Obtém a faixa de alarme do sensor de temperatura interno(% style="display:none" %) 973 973 ))) 974 974 975 975 ((( 976 -**AT+ARTEMP=45,105**: Settheinternaltemperature sensoralarmrange from45to105.976 +**AT+ARTEMP=45,105**: Defina a faixa interna do alarme do sensor de temperatura de 45 a 105. 977 977 ))) 978 978 ))) 979 979