Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -913,10 +913,10 @@ 913 913 914 914 915 915 916 -= 4.LDS12via AT Command or LoRaWAN Downlink =916 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink = 917 917 918 918 ((( 919 -Use can configure L LDS12via AT Command or LoRaWAN Downlink.919 +Use can configure LSPH01 via AT Command or LoRaWAN Downlink. 920 920 ))) 921 921 922 922 * ((( ... ... @@ -927,9 +927,7 @@ 927 927 ))) 928 928 929 929 ((( 930 - 931 - 932 -There are two kinds of commands to configure LLDS12, they are: 930 +There are two kinds of commands to configure LSPH01, they are: 933 933 ))) 934 934 935 935 * ((( ... ... @@ -948,7 +948,7 @@ 948 948 ))) 949 949 950 950 ((( 951 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 949 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>path:/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 952 952 ))) 953 953 954 954 ((( ... ... @@ -956,16 +956,16 @@ 956 956 ))) 957 957 958 958 * ((( 959 -(% style="color:#4f81bd" %)** Commands special design for L LDS12**957 +(% style="color:#4f81bd" %)** Commands special design for LSPH01** 960 960 ))) 961 961 962 962 ((( 963 -These commands only valid for L LDS12, as below:961 +These commands only valid for LSPH01, as below: 964 964 ))) 965 965 966 966 967 967 968 -== 4.1966 +== 3.1 Set Transmit Interval Time == 969 969 970 970 Feature: Change LoRaWAN End Node Transmit Interval. 971 971 ... ... @@ -997,17 +997,15 @@ 997 997 998 998 ))) 999 999 1000 -== 4.2998 +== 3.2 Set Interrupt Mode == 1001 1001 1002 1002 Feature, Set Interrupt mode for GPIO_EXIT. 1003 1003 1004 1004 (% style="color:#037691" %)**AT Command: AT+INTMOD** 1005 1005 1006 -[[image:image-202206 10105806-2.png]]1004 +[[image:image-20220607171716-9.png]] 1007 1007 1008 1008 1009 - 1010 - 1011 1011 ((( 1012 1012 (% style="color:#037691" %)**Downlink Command: 0x06** 1013 1013 ))) ... ... @@ -1027,10 +1027,20 @@ 1027 1027 Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1028 1028 ))) 1029 1029 1026 +((( 1027 + 1028 +))) 1030 1030 1031 1031 1032 -== 4.3 Get Firmware Version Info == 1033 1033 1032 +== 3.3 Calibrate Sensor == 1033 + 1034 +Detail See [[Calibration Guide>>||anchor="H2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands 1035 + 1036 + 1037 + 1038 +== 3.4 Get Firmware Version Info == 1039 + 1034 1034 Feature: use downlink to get firmware version. 1035 1035 1036 1036 (% style="color:#037691" %)**Downlink Command: 0x26** ... ... @@ -1111,12 +1111,12 @@ 1111 1111 1112 1112 1113 1113 1114 -= 5.1120 += 4. Battery & How to replace = 1115 1115 1116 -== 5.11122 +== 4.1 Battery Type == 1117 1117 1118 1118 ((( 1119 -L LDS12is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.1125 +LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 1120 1120 ))) 1121 1121 1122 1122 ((( ... ... @@ -1126,13 +1126,13 @@ 1126 1126 [[image:1654593587246-335.png]] 1127 1127 1128 1128 1129 -Minimum Working Voltage for the L LDS12:1135 +Minimum Working Voltage for the LSPH01: 1130 1130 1131 -L LDS12: 2.45v ~~ 3.6v1137 +LSPH01: 2.45v ~~ 3.6v 1132 1132 1133 1133 1134 1134 1135 -== 5.21141 +== 4.2 Replace Battery == 1136 1136 1137 1137 ((( 1138 1138 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. ... ... @@ -1144,7 +1144,7 @@ 1144 1144 1145 1145 1146 1146 1147 -== 5.31153 +== 4.3 Power Consumption Analyze == 1148 1148 1149 1149 ((( 1150 1150 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. ... ... @@ -1187,7 +1187,7 @@ 1187 1187 1188 1188 1189 1189 1190 -=== 5.3.11196 +=== 4.3.1 Battery Note === 1191 1191 1192 1192 ((( 1193 1193 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. ... ... @@ -1195,14 +1195,14 @@ 1195 1195 1196 1196 1197 1197 1198 -=== 5.3.21204 +=== 4.3.2 Replace the battery === 1199 1199 1200 1200 ((( 1201 -You can change the battery in the L LDS12.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.1207 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 1202 1202 ))) 1203 1203 1204 1204 ((( 1205 -The default battery pack of L LDS12includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)1211 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 1206 1206 ))) 1207 1207 1208 1208 ... ... @@ -1211,7 +1211,7 @@ 1211 1211 1212 1212 == 6.1 Access AT Commands == 1213 1213 1214 -L LDS12supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LLDS12for using AT command, as below.1220 +LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 1215 1215 1216 1216 [[image:1654593668970-604.png]] 1217 1217
- image-20220610105806-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -15.5 KB - Content