Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 3 removed)
Details
- Page properties
-
- Content
-
... ... @@ -68,6 +68,8 @@ 68 68 69 69 70 70 71 + 72 + 71 71 = 1. Introduction = 72 72 73 73 == 1.1 What is LoRaWAN Soil pH Sensor == ... ... @@ -104,7 +104,6 @@ 104 104 * 8500mAh Battery for long term use 105 105 106 106 107 - 108 108 == 1.3 Probe Specification == 109 109 110 110 ... ... @@ -126,13 +126,11 @@ 126 126 * Length: 3.5 meters 127 127 128 128 129 - 130 130 == 1.4 Applications == 131 131 132 132 * Smart Agriculture 133 133 134 134 135 - 136 136 == 1.5 Pin mapping and power on == 137 137 138 138 [[image:1654592472094-134.png]] ... ... @@ -320,7 +320,6 @@ 320 320 321 321 322 322 323 - 324 324 === 2.3.7 Decode payload in The Things Network === 325 325 326 326 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -483,6 +483,7 @@ 483 483 Always 0x03 484 484 ))) 485 485 484 + 486 486 User can also send 0x14 downlink command to poll the current calibration payload. 487 487 488 488 [[image:image-20220607171416-7.jpeg]] ... ... @@ -493,7 +493,6 @@ 493 493 494 494 495 495 496 - 497 497 == 2.8 Frequency Plans == 498 498 499 499 ((( ... ... @@ -550,6 +550,8 @@ 550 550 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 551 551 552 552 551 + 552 + 553 553 === 2.8.3 CN470-510 (CN470) === 554 554 555 555 Used in China, Default use CHE=1 ... ... @@ -617,6 +617,8 @@ 617 617 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 618 618 619 619 620 + 621 + 620 620 === 2.8.5 AS920-923 & AS923-925 (AS923) === 621 621 622 622 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -732,6 +732,8 @@ 732 732 * Blink once when device transmit a packet. 733 733 734 734 737 + 738 + 735 735 == 2.10 Firmware Change Log == 736 736 737 737 ... ... @@ -790,7 +790,6 @@ 790 790 791 791 792 792 793 - 794 794 == 3.2 Set Interrupt Mode == 795 795 796 796 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -810,6 +810,8 @@ 810 810 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 811 811 812 812 816 + 817 + 813 813 == 3.3 Calibrate Sensor == 814 814 815 815 Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -956,7 +956,7 @@ 956 956 957 957 And the Life expectation in difference case will be shown on the right. 958 958 959 -[[image:16545 93605679-189.png]]964 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654588577573-122.png?rev=1.1||alt="1654588577573-122.png"]] 960 960 961 961 962 962 The battery related documents as below: ... ... @@ -971,7 +971,7 @@ 971 971 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 972 972 ))) 973 973 974 -[[image:image-202206071 72042-11.png]]979 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/image-20220607155856-8.png?rev=1.1||alt="image-20220607155856-8.png"]] 975 975 976 976 977 977 ... ... @@ -997,7 +997,7 @@ 997 997 998 998 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 999 999 1000 -[[image:16545936 68970-604.png]]1005 +[[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654589001411-343.png?rev=1.1||alt="1654589001411-343.png"]] 1001 1001 1002 1002 **Connection:** 1003 1003 ... ... @@ -1011,7 +1011,7 @@ 1011 1011 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 1012 1012 1013 1013 1014 - [[image:165459 3712276-618.png]]1019 + [[image:/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSPH01-LoRaWAN%20Soil%20pH%20Sensor%20User%20Manual/WebHome/1654589062541-567.png?rev=1.1||alt="1654589062541-567.png"]] 1015 1015 1016 1016 Valid AT Command please check [[Configure Device>>path:#H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink]]. 1017 1017 ... ... @@ -1050,7 +1050,6 @@ 1050 1050 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1051 1051 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1052 1052 1053 - 1054 1054 = 9. Packing Info = 1055 1055 1056 1056 ... ... @@ -1065,10 +1065,8 @@ 1065 1065 * Package Size / pcs : cm 1066 1066 * Weight / pcs : g 1067 1067 1068 - 1069 1069 = 10. Support = 1070 1070 1071 1071 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1072 1072 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]. 1073 1073 1074 -
- 1654593668970-604.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -546.2 KB - Content
- 1654593712276-618.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -144.0 KB - Content
- image-20220607172042-11.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -83.7 KB - Content