Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -67,7 +67,6 @@ 67 67 68 68 69 69 70 - 71 71 = 1. Introduction = 72 72 73 73 == 1.1 What is LoRaWAN Soil pH Sensor == ... ... @@ -114,7 +114,6 @@ 114 114 * 8500mAh Battery for long term use 115 115 116 116 117 - 118 118 == 1.3 Probe Specification == 119 119 120 120 ... ... @@ -136,13 +136,11 @@ 136 136 * Length: 3.5 meters 137 137 138 138 139 - 140 140 == 1.4 Applications == 141 141 142 142 * Smart Agriculture 143 143 144 144 145 - 146 146 == 1.5 Pin mapping and power on == 147 147 148 148 [[image:1654592472094-134.png]] ... ... @@ -335,7 +335,7 @@ 335 335 336 336 337 337 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 338 -|**Message Type Code**|**Description**|**Payload** 334 +|=**Message Type Code**|=**Description**|=**Payload** 339 339 |0x01|Normal Uplink|[[Normal Uplink Payload>>path:#H2.3200BUplinkPayload]] 340 340 |0x02|Reply configures info|[[Configure Info Payload>>path:#H3.4GetFirmwareVersionInfo]] 341 341 |0x03|Reply Calibration Info|[[Calibration Payload>>path:#H2.7Calibration]] ... ... @@ -342,7 +342,6 @@ 342 342 343 343 344 344 345 - 346 346 === 2.3.7 Decode payload in The Things Network === 347 347 348 348 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -368,12 +368,21 @@ 368 368 369 369 == 2.5 Show Data in DataCake IoT Server == 370 370 366 +((( 371 371 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 368 +))) 372 372 370 +((( 371 + 372 +))) 373 373 374 +((( 374 374 (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** 376 +))) 375 375 378 +((( 376 376 (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:** 380 +))) 377 377 378 378 379 379 [[image:1654592790040-760.png]] ... ... @@ -396,9 +396,13 @@ 396 396 [[image:1654592856403-259.png]] 397 397 398 398 403 +((( 399 399 (% style="color:blue" %)**Step 5**(%%)**: add payload decode** 405 +))) 400 400 407 +((( 401 401 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]] 409 +))) 402 402 403 403 404 404 [[image:1654592878525-845.png]] ... ... @@ -421,8 +421,10 @@ 421 421 === 2.6.1 Before measurement === 422 422 423 423 ((( 432 +((( 424 424 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 425 425 ))) 435 +))) 426 426 427 427 428 428 ... ... @@ -429,24 +429,45 @@ 429 429 === 2.6.2 Measurement === 430 430 431 431 442 +((( 432 432 (% style="color:#4f81bd" %)**Measurement the soil surface:** 444 +))) 433 433 446 +((( 434 434 [[image:1654592946732-634.png]] 448 +))) 435 435 450 +((( 436 436 Choose the proper measuring position. Split the surface soil according to the measured deep. 452 +))) 437 437 454 +((( 438 438 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 456 +))) 439 439 458 +((( 440 440 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting. 460 +))) 441 441 462 +((( 442 442 Put soil over the probe after insert. And start to measure. 464 +))) 443 443 466 +((( 467 + 468 +))) 444 444 470 +((( 445 445 (% style="color:#4f81bd" %)**Measurement inside soil:** 472 +))) 446 446 474 +((( 447 447 Dig a hole with diameter > 20CM. 476 +))) 448 448 478 +((( 449 449 Insert the probe inside, method like measure the surface. 480 +))) 450 450 451 451 452 452 ... ... @@ -476,9 +476,13 @@ 476 476 477 477 == 2.7 Calibration == 478 478 510 +((( 479 479 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 512 +))) 480 480 514 +((( 481 481 After stable, user can use below command to calibrate. 516 +))) 482 482 483 483 [[image:image-20220607171149-4.png]] 484 484 ... ... @@ -515,7 +515,6 @@ 515 515 516 516 517 517 518 - 519 519 == 2.8 Frequency Plans == 520 520 521 521 ((( ... ... @@ -571,7 +571,6 @@ 571 571 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 572 572 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 573 573 574 - 575 575 === 2.8.3 CN470-510 (CN470) === 576 576 577 577 Used in China, Default use CHE=1 ... ... @@ -639,7 +639,6 @@ 639 639 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 640 640 641 641 642 - 643 643 === 2.8.5 AS920-923 & AS923-925 (AS923) === 644 644 645 645 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -755,7 +755,6 @@ 755 755 * Blink once when device transmit a packet. 756 756 757 757 758 - 759 759 == 2.10 Firmware Change Log == 760 760 761 761 ... ... @@ -814,7 +814,6 @@ 814 814 815 815 816 816 817 - 818 818 == 3.2 Set Interrupt Mode == 819 819 820 820 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -833,7 +833,6 @@ 833 833 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 834 834 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 835 835 836 - 837 837 == 3.3 Calibrate Sensor == 838 838 839 839 Detail See [[Calibration Guide>>path:#H2.7Calibration]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -851,7 +851,6 @@ 851 851 * Reply to the confirmation package: 26 01 852 852 * Reply to non-confirmed packet: 26 00 853 853 854 - 855 855 Device will send an uplink after got this downlink command. With below payload: 856 856 857 857 Configures info payload: ... ... @@ -1074,7 +1074,6 @@ 1074 1074 * (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1075 1075 * (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1076 1076 1077 - 1078 1078 = 9. Packing Info = 1079 1079 1080 1080 ... ... @@ -1089,7 +1089,6 @@ 1089 1089 * Package Size / pcs : cm 1090 1090 * Weight / pcs : g 1091 1091 1092 - 1093 1093 = 10. Support = 1094 1094 1095 1095 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.