- Content
-
... ... @@ -55,8 +55,6 @@ 55 55 * IP68 rate for the Sensor Probe 56 56 * 8500mAh Battery for long term use 57 57 58 - 59 - 60 60 == 1.3 Probe Specification == 61 61 62 62 ... ... @@ -77,12 +77,10 @@ 77 77 * IP68 Protection 78 78 * Length: 3.5 meters 79 79 80 - 81 81 == 1.4 Applications == 82 82 83 83 * Smart Agriculture 84 84 85 - 86 86 == 1.5 Pin mapping and power on == 87 87 88 88 [[image:1654580482666-473.png]] ... ... @@ -98,7 +98,7 @@ 98 98 ))) 99 99 100 100 ((( 101 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.UseATCommand"]]to set the keys in the LSPH01. 97 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H5.200BUseATCommand"]]to set the keys in the LSPH01. 102 102 ))) 103 103 104 104 ... ... @@ -265,12 +265,10 @@ 265 265 266 266 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 267 267 |**Message Type Code**|**Description**|**Payload** 268 -|0x01|Normal Uplink|[[Normal Uplink Payload>>||anchor="H2.3 200BUplinkPayload"]]264 +|0x01|Normal Uplink|[[Normal Uplink Payload>>||anchor="H2.3Uplink Payload"]] 269 269 |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 270 270 |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]] 271 271 272 - 273 - 274 274 === 2.3.7 Decode payload in The Things Network === 275 275 276 276 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -440,6 +440,8 @@ 440 440 * Reply to the confirmation package: 14 01 441 441 * Reply to non-confirmed packet: 14 00 442 442 437 + 438 + 443 443 == 2.8 Frequency Plans == 444 444 445 445 ((( ... ... @@ -495,6 +495,9 @@ 495 495 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 496 496 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 497 497 494 + 495 + 496 + 498 498 === 2.8.3 CN470-510 (CN470) === 499 499 500 500 Used in China, Default use CHE=1 ... ... @@ -561,6 +561,7 @@ 561 561 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 562 562 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 563 563 563 + 564 564 === 2.8.5 AS920-923 & AS923-925 (AS923) === 565 565 566 566 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -675,7 +675,6 @@ 675 675 * Blink once when device transmit a packet. 676 676 677 677 678 - 679 679 == 2.10 Firmware Change Log == 680 680 681 681 ... ... @@ -744,6 +744,9 @@ 744 744 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 745 745 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 746 746 746 + 747 + 748 + 747 747 == 3.2 Set Interrupt Mode == 748 748 749 749 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -779,7 +779,6 @@ 779 779 * Reply to the confirmation package: 26 01 780 780 * Reply to non-confirmed packet: 26 00 781 781 782 - 783 783 Device will send an uplink after got this downlink command. With below payload: 784 784 785 785 Configures info payload: ... ... @@ -951,7 +951,7 @@ 951 951 952 952 [[image:1654589001411-343.png]] 953 953 954 - **Connection:**955 +Connection: 955 955 956 956 (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 957 957 ... ... @@ -960,7 +960,7 @@ 960 960 (% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 961 961 962 962 963 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%)to access the serial console for LSPH01. LSPH01 will output system info once power on as below:964 +In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 964 964 965 965 966 966 [[image:1654589062541-567.png]] ... ... @@ -969,42 +969,39 @@ 969 969 970 970 971 971 972 -= 6. FAQ = 973 973 974 -== 6.1 How to change the LoRa Frequency Bands/Region == 974 +1. FAQ 975 +11. How to change the LoRa Frequency Bands/Region 975 975 976 -You can follow the instructions for [[how to upgrade image>> ||anchor="H2.10200BFirmwareChangeLog"]].977 +You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 977 977 When downloading the images, choose the required image file for download. 978 978 979 979 980 980 981 -= 7. Trouble Shooting = 982 +1. Trouble Shooting 983 +11. AT Commands input doesn’t work 982 982 983 - ==7.1ATCommandsinput doesn’t work==985 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string. 984 984 985 -In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 986 986 988 +1. Order Info 987 987 990 +Part Number: **LSPH01-XX** 988 988 989 -= 8. Order Info = 990 990 991 - PartNumber:(% style="color:blue"%)**LSPH01-XX**993 +**XX**: The default frequency band 992 992 995 +* **AS923**: LoRaWAN AS923 band 996 +* **AU915**: LoRaWAN AU915 band 997 +* **EU433**: LoRaWAN EU433 band 998 +* **EU868**: LoRaWAN EU868 band 999 +* **KR920**: LoRaWAN KR920 band 1000 +* **US915**: LoRaWAN US915 band 1001 +* **IN865**: LoRaWAN IN865 band 1002 +* **CN470**: LoRaWAN CN470 band 993 993 994 - (%style="color:blue" %)**XX**(%%): The default frequencyband1004 +1. Packing Info 995 995 996 -* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 997 -* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 998 -* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 999 -* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1000 -* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1001 -* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1002 -* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1003 -* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1004 - 1005 -= 9. Packing Info = 1006 - 1007 - 1008 1008 **Package Includes**: 1009 1009 1010 1010 * LSPH01 LoRaWAN Soil Ph Sensor x 1 ... ... @@ -1016,10 +1016,11 @@ 1016 1016 * Package Size / pcs : cm 1017 1017 * Weight / pcs : g 1018 1018 1019 - 1020 1020 = 10. Support = 1021 1021 1022 1022 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1023 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].1020 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1024 1024 1022 +[[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1023 + 1025 1025