Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -893,12 +893,12 @@ 893 893 ))) 894 894 895 895 896 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 896 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 897 897 898 898 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 899 899 900 900 901 -Step 2: Open it and choose 901 +**Step 2**: Open it and choose 902 902 903 903 * Product Model 904 904 * Uplink Interval ... ... @@ -925,33 +925,29 @@ 925 925 926 926 927 927 928 -1. 929 -11. 930 -111. Battery Note 928 +=== 4.3.1 Battery Note === 931 931 930 +((( 932 932 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 932 +))) 933 933 934 934 935 -1. 936 -11. 937 -111. Replace the battery 938 938 936 +=== 4.3.2 Replace the battery === 937 + 939 939 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 940 940 941 - 942 942 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 943 943 944 944 945 945 944 += 5. Use AT Command = 946 946 946 +== 5.1 Access AT Commands == 947 947 948 - 949 -1. Use AT Command 950 -11. Access AT Commands 951 - 952 952 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 953 953 954 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]950 +[[image:1654589001411-343.png]] 955 955 956 956 Connection: 957 957
- 1654589001411-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +546.2 KB - Content