Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -55,6 +55,9 @@ 55 55 * IP68 rate for the Sensor Probe 56 56 * 8500mAh Battery for long term use 57 57 58 + 59 + 60 + 58 58 == 1.3 Probe Specification == 59 59 60 60 ... ... @@ -75,6 +75,8 @@ 75 75 * IP68 Protection 76 76 * Length: 3.5 meters 77 77 81 + 82 + 78 78 == 1.4 Applications == 79 79 80 80 * Smart Agriculture ... ... @@ -434,8 +434,6 @@ 434 434 * Reply to the confirmation package: 14 01 435 435 * Reply to non-confirmed packet: 14 00 436 436 437 - 438 - 439 439 == 2.8 Frequency Plans == 440 440 441 441 ((( ... ... @@ -492,7 +492,6 @@ 492 492 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 493 493 494 494 495 - 496 496 === 2.8.3 CN470-510 (CN470) === 497 497 498 498 Used in China, Default use CHE=1 ... ... @@ -559,9 +559,6 @@ 559 559 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 560 560 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 561 561 562 - 563 - 564 - 565 565 === 2.8.5 AS920-923 & AS923-925 (AS923) === 566 566 567 567 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -879,26 +879,33 @@ 879 879 880 880 == 4.2 Replace Battery == 881 881 881 +((( 882 882 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 883 +))) 883 883 885 +((( 884 884 And make sure the positive and negative pins match. 887 +))) 885 885 886 886 887 887 888 888 == 4.3 Power Consumption Analyze == 889 889 893 +((( 890 890 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 895 +))) 891 891 892 - 897 +((( 893 893 Instruction to use as below: 899 +))) 894 894 895 895 896 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 902 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 897 897 898 898 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 899 899 900 900 901 -Step 2: Open it and choose 907 +**Step 2**: Open it and choose 902 902 903 903 * Product Model 904 904 * Uplink Interval ... ... @@ -906,102 +906,104 @@ 906 906 907 907 And the Life expectation in difference case will be shown on the right. 908 908 909 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]915 +[[image:1654588577573-122.png]] 910 910 911 911 912 912 The battery related documents as below: 913 913 914 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]], 915 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet 916 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 917 - 918 -|((( 919 -JST-XH-2P connector 920 +* ((( 921 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 920 920 ))) 923 +* ((( 924 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 925 +))) 926 +* ((( 927 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 928 +))) 921 921 922 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]930 +[[image:image-20220607155856-8.png]] 923 923 924 924 925 925 926 -1. 927 -11. 928 -111. Battery Note 934 +=== 4.3.1 Battery Note === 929 929 936 +((( 930 930 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 938 +))) 931 931 932 932 933 -1. 934 -11. 935 -111. Replace the battery 936 936 942 +=== 4.3.2 Replace the battery === 943 + 937 937 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 938 938 939 - 940 940 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 941 941 942 942 943 943 950 += 5. Use AT Command = 944 944 952 +== 5.1 Access AT Commands == 945 945 946 - 947 -1. Use AT Command 948 -11. Access AT Commands 949 - 950 950 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 951 951 952 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]956 +[[image:1654589001411-343.png]] 953 953 954 -Connection: 958 +**Connection:** 955 955 956 -USB TTL GND <~-~-~-~-> GND 960 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 957 957 958 -USB TTL TXD <~-~-~-~-> UART_RXD 962 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 959 959 960 -USB TTL RXD <~-~-~-~-> UART_TXD 964 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 961 961 962 962 963 -In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 967 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 964 964 965 965 966 - [[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]970 + [[image:1654589062541-567.png]] 967 967 968 968 Valid AT Command please check [[Configure Device>>path:#Configure_Device]]. 969 969 970 970 971 971 976 += 6. FAQ = 972 972 973 -1. FAQ 974 -11. How to change the LoRa Frequency Bands/Region 978 +== 6.1 How to change the LoRa Frequency Bands/Region == 975 975 976 -You can follow the instructions for [[how to upgrade image>> path:#3ygebqi]].980 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 977 977 When downloading the images, choose the required image file for download. 978 978 979 979 980 980 981 -1. Trouble Shooting 982 -11. AT Commands input doesn’t work 985 += 7. Trouble Shooting = 983 983 984 - Inthe case if user can see the console output but can’t type input to the device.Please check if you already include the **ENTER**while sendingout the command. Someserialtooldoesn’tsend **ENTER**while press the sendkey,user need to add ENTER in their string.987 +== 7.1 AT Commands input doesn’t work == 985 985 989 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 986 986 987 -1. Order Info 988 988 989 -Part Number: **LSPH01-XX** 990 990 993 += 8. Order Info = 991 991 992 - **XX**:Thedefault frequencyband995 +Part Number: (% style="color:blue" %)**LSPH01-XX** 993 993 994 -* **AS923**: LoRaWAN AS923 band 995 -* **AU915**: LoRaWAN AU915 band 996 -* **EU433**: LoRaWAN EU433 band 997 -* **EU868**: LoRaWAN EU868 band 998 -* **KR920**: LoRaWAN KR920 band 999 -* **US915**: LoRaWAN US915 band 1000 -* **IN865**: LoRaWAN IN865 band 1001 -* **CN470**: LoRaWAN CN470 band 1002 1002 1003 - 1.PackingInfo998 +(% style="color:blue" %)**XX**(%%): The default frequency band 1004 1004 1000 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 1001 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 1002 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 1003 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1004 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1005 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1006 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1007 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1008 + 1009 + 1010 += 9. Packing Info = 1011 + 1012 + 1005 1005 **Package Includes**: 1006 1006 1007 1007 * LSPH01 LoRaWAN Soil Ph Sensor x 1 ... ... @@ -1013,11 +1013,11 @@ 1013 1013 * Package Size / pcs : cm 1014 1014 * Weight / pcs : g 1015 1015 1024 + 1025 + 1016 1016 = 10. Support = 1017 1017 1018 1018 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1019 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to 1029 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]. 1020 1020 1021 -[[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1022 - 1023 1023
- 1654588577573-122.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +138.2 KB - Content
- 1654589001411-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +546.2 KB - Content
- 1654589062541-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.0 KB - Content
- image-20220607155856-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.5 KB - Content