Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -434,8 +434,6 @@ 434 434 * Reply to the confirmation package: 14 01 435 435 * Reply to non-confirmed packet: 14 00 436 436 437 - 438 - 439 439 == 2.8 Frequency Plans == 440 440 441 441 ((( ... ... @@ -492,7 +492,6 @@ 492 492 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 493 493 494 494 495 - 496 496 === 2.8.3 CN470-510 (CN470) === 497 497 498 498 Used in China, Default use CHE=1 ... ... @@ -672,6 +672,9 @@ 672 672 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 673 673 * Blink once when device transmit a packet. 674 674 672 + 673 + 674 + 675 675 == 2.10 Firmware Change Log == 676 676 677 677 ... ... @@ -777,6 +777,8 @@ 777 777 * Reply to the confirmation package: 26 01 778 778 * Reply to non-confirmed packet: 26 00 779 779 780 + 781 + 780 780 Device will send an uplink after got this downlink command. With below payload: 781 781 782 782 Configures info payload: ... ... @@ -848,18 +848,19 @@ 848 848 849 849 850 850 853 += 4. Battery & How to replace = 851 851 855 +== 4.1 Battery Type == 852 852 853 - 854 -1. Battery & How to replace 855 -11. Battery Type 856 - 857 +((( 857 857 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 859 +))) 858 858 859 - 861 +((( 860 860 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 863 +))) 861 861 862 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]865 +[[image:1654588469844-778.png]] 863 863 864 864 865 865 Minimum Working Voltage for the LSPH01: ... ... @@ -867,30 +867,36 @@ 867 867 LSPH01: 2.45v ~~ 3.6v 868 868 869 869 870 -1. 871 -11. Replace Battery 872 872 874 +== 4.2 Replace Battery == 875 + 876 +((( 873 873 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 878 +))) 874 874 880 +((( 875 875 And make sure the positive and negative pins match. 882 +))) 876 876 877 877 878 878 879 -1. 880 -11. Power Consumption Analyze 886 +== 4.3 Power Consumption Analyze == 881 881 888 +((( 882 882 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 890 +))) 883 883 884 - 892 +((( 885 885 Instruction to use as below: 894 +))) 886 886 887 887 888 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 897 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 889 889 890 890 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 891 891 892 892 893 -Step 2: Open it and choose 902 +**Step 2**: Open it and choose 894 894 895 895 * Product Model 896 896 * Uplink Interval ... ... @@ -898,64 +898,62 @@ 898 898 899 899 And the Life expectation in difference case will be shown on the right. 900 900 901 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]910 +[[image:1654588577573-122.png]] 902 902 903 903 904 904 The battery related documents as below: 905 905 906 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]], 907 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet 908 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 909 - 910 -|((( 911 -JST-XH-2P connector 915 +* ((( 916 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 912 912 ))) 918 +* ((( 919 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 920 +))) 921 +* ((( 922 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 923 +))) 913 913 914 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]925 +[[image:image-20220607155856-8.png]] 915 915 916 916 917 917 918 -1. 919 -11. 920 -111. Battery Note 929 +=== 4.3.1 Battery Note === 921 921 931 +((( 922 922 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 933 +))) 923 923 924 924 925 -1. 926 -11. 927 -111. Replace the battery 928 928 937 +=== 4.3.2 Replace the battery === 938 + 929 929 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 930 930 931 - 932 932 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 933 933 934 934 935 935 945 += 5. Use AT Command = 936 936 947 +== 5.1 Access AT Commands == 937 937 938 - 939 -1. Use AT Command 940 -11. Access AT Commands 941 - 942 942 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 943 943 944 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]951 +[[image:1654589001411-343.png]] 945 945 946 -Connection: 953 +**Connection:** 947 947 948 -USB TTL GND <~-~-~-~-> GND 955 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 949 949 950 -USB TTL TXD <~-~-~-~-> UART_RXD 957 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 951 951 952 -USB TTL RXD <~-~-~-~-> UART_TXD 959 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 953 953 954 954 955 -In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 962 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 956 956 957 957 958 - [[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]965 + [[image:1654589062541-567.png]] 959 959 960 960 Valid AT Command please check [[Configure Device>>path:#Configure_Device]]. 961 961 ... ... @@ -962,38 +962,43 @@ 962 962 963 963 964 964 965 -1. FAQ 966 -11. How to change the LoRa Frequency Bands/Region 972 += 6. FAQ = 967 967 968 -You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 974 +== 6.1 How to change the LoRa Frequency Bands/Region == 975 + 976 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 969 969 When downloading the images, choose the required image file for download. 970 970 971 971 972 972 973 -1. Trouble Shooting 974 -11. AT Commands input doesn’t work 981 += 7. Trouble Shooting = 975 975 976 - Inthe case if user can see the console output but can’t type input to the device.Please check if you already include the **ENTER**while sendingout the command. Someserialtooldoesn’tsend **ENTER**while press the sendkey,user need to add ENTER in their string.983 +== 7.1 AT Commands input doesn’t work == 977 977 985 +In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 978 978 979 -1. Order Info 980 980 981 -Part Number: **LSPH01-XX** 982 982 989 += 8. Order Info = 983 983 984 - **XX**:Thedefault frequencyband991 +Part Number: (% style="color:blue" %)**LSPH01-XX** 985 985 986 -* **AS923**: LoRaWAN AS923 band 987 -* **AU915**: LoRaWAN AU915 band 988 -* **EU433**: LoRaWAN EU433 band 989 -* **EU868**: LoRaWAN EU868 band 990 -* **KR920**: LoRaWAN KR920 band 991 -* **US915**: LoRaWAN US915 band 992 -* **IN865**: LoRaWAN IN865 band 993 -* **CN470**: LoRaWAN CN470 band 994 994 995 - 1.PackingInfo994 +(% style="color:blue" %)**XX**(%%): The default frequency band 996 996 996 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band 997 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band 998 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band 999 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band 1000 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band 1001 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band 1002 +* (% style="color:red" %)**IN865**(%%): LoRaWAN IN865 band 1003 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band 1004 + 1005 + 1006 += 9. Packing Info = 1007 + 1008 + 997 997 **Package Includes**: 998 998 999 999 * LSPH01 LoRaWAN Soil Ph Sensor x 1
- 1654588469844-778.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +75.8 KB - Content
- 1654588577573-122.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +138.2 KB - Content
- 1654589001411-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +546.2 KB - Content
- 1654589062541-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.0 KB - Content
- image-20220607155856-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.5 KB - Content