Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -435,7 +435,6 @@ 435 435 * Reply to non-confirmed packet: 14 00 436 436 437 437 438 - 439 439 == 2.8 Frequency Plans == 440 440 441 441 ((( ... ... @@ -491,6 +491,8 @@ 491 491 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 492 492 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 493 493 493 + 494 + 494 494 === 2.8.3 CN470-510 (CN470) === 495 495 496 496 Used in China, Default use CHE=1 ... ... @@ -739,6 +739,7 @@ 739 739 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 740 740 741 741 743 + 742 742 == 3.2 Set Interrupt Mode == 743 743 744 744 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -758,6 +758,7 @@ 758 758 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 759 759 760 760 763 + 761 761 == 3.3 Calibrate Sensor == 762 762 763 763 Detail See [[Calibration Guide>>||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -846,18 +846,19 @@ 846 846 847 847 848 848 852 += 4. Battery & How to replace = 849 849 854 +== 4.1 Battery Type == 850 850 851 - 852 -1. Battery & How to replace 853 -11. Battery Type 854 - 856 +((( 855 855 LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 858 +))) 856 856 857 - 860 +((( 858 858 The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 862 +))) 859 859 860 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image022.png]]864 +[[image:1654588469844-778.png]] 861 861 862 862 863 863 Minimum Working Voltage for the LSPH01: ... ... @@ -865,30 +865,36 @@ 865 865 LSPH01: 2.45v ~~ 3.6v 866 866 867 867 868 -1. 869 -11. Replace Battery 870 870 873 +== 4.2 Replace Battery == 874 + 875 +((( 871 871 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 877 +))) 872 872 879 +((( 873 873 And make sure the positive and negative pins match. 881 +))) 874 874 875 875 876 876 877 -1. 878 -11. Power Consumption Analyze 885 +== 4.3 Power Consumption Analyze == 879 879 887 +((( 880 880 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 889 +))) 881 881 882 - 891 +((( 883 883 Instruction to use as below: 893 +))) 884 884 885 885 886 -Step 1: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 896 +**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 887 887 888 888 [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 889 889 890 890 891 -Step 2: Open it and choose 901 +**Step 2**: Open it and choose 892 892 893 893 * Product Model 894 894 * Uplink Interval ... ... @@ -896,64 +896,62 @@ 896 896 897 897 And the Life expectation in difference case will be shown on the right. 898 898 899 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image023.png]]909 +[[image:1654588577573-122.png]] 900 900 901 901 902 902 The battery related documents as below: 903 903 904 -* [[Battery Dimension>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]], 905 -* [[Lithium-Thionyl Chloride Battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] datasheet 906 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 907 - 908 -|((( 909 -JST-XH-2P connector 914 +* ((( 915 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 910 910 ))) 917 +* ((( 918 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 919 +))) 920 +* ((( 921 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 922 +))) 911 911 912 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image024.png]]924 +[[image:image-20220607155856-8.png]] 913 913 914 914 915 915 916 -1. 917 -11. 918 -111. Battery Note 928 +=== 4.3.1 Battery Note === 919 919 930 +((( 920 920 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 932 +))) 921 921 922 922 923 -1. 924 -11. 925 -111. Replace the battery 926 926 936 +=== 4.3.2 Replace the battery === 937 + 927 927 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 928 928 929 - 930 930 The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 931 931 932 932 933 933 944 += 5. Use AT Command = 934 934 946 +== 5.1 Access AT Commands == 935 935 936 - 937 -1. Use AT Command 938 -11. Access AT Commands 939 - 940 940 LSPH01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSPH01 for using AT command, as below. 941 941 942 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image025.png]]950 +[[image:1654589001411-343.png]] 943 943 944 -Connection: 952 +**Connection:** 945 945 946 -USB TTL GND <~-~-~-~-> GND 954 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 947 947 948 -USB TTL TXD <~-~-~-~-> UART_RXD 956 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 949 949 950 -USB TTL RXD <~-~-~-~-> UART_TXD 958 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 951 951 952 952 953 -In the PC, you need to set the serial baud rate to **9600** to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 961 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSPH01. LSPH01 will output system info once power on as below: 954 954 955 955 956 - [[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image026.png]]964 + [[image:1654589062541-567.png]] 957 957 958 958 Valid AT Command please check [[Configure Device>>path:#Configure_Device]]. 959 959 ... ... @@ -960,17 +960,19 @@ 960 960 961 961 962 962 963 -1. FAQ 964 -11. How to change the LoRa Frequency Bands/Region 971 += 6. FAQ = 965 965 966 -You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 973 +== 6.1 How to change the LoRa Frequency Bands/Region == 974 + 975 +You can follow the instructions for [[how to upgrade image>>||anchor="H3.ConfigureLSPH01viaATCommandorLoRaWANDownlink"]]. 967 967 When downloading the images, choose the required image file for download. 968 968 969 969 970 970 971 -1. Trouble Shooting 972 -11. AT Commands input doesn’t work 980 += 7. Trouble Shooting = 973 973 982 +== 7.1 AT Commands input doesn’t work == 983 + 974 974 In the case if user can see the console output but can’t type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn’t send **ENTER** while press the send key, user need to add ENTER in their string. 975 975 976 976
- 1654588469844-778.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +75.8 KB - Content
- 1654588577573-122.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +138.2 KB - Content
- 1654589001411-343.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +546.2 KB - Content
- 1654589062541-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +144.0 KB - Content
- image-20220607155856-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.5 KB - Content