Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -555,7 +555,6 @@ 555 555 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 556 556 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 557 557 558 - 559 559 === 2.8.5 AS920-923 & AS923-925 (AS923) === 560 560 561 561 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -737,18 +737,31 @@ 737 737 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 738 738 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 739 739 739 +1. 740 +11. Set Interrupt Mode 740 740 742 +Feature, Set Interrupt mode for GPIO_EXIT. 741 741 742 - ==3.2 Set Interrupt Mode==744 +**AT Command: AT+INTMOD** 743 743 744 -Feature, Set Interrupt mode for GPIO_EXIT. 746 +|**Command Example**|**Function**|**Response** 747 +|AT+INTMOD=?|Show current interrupt mode|((( 748 +0 745 745 746 - (% style="color:#037691" %)**AT Command: AT+INTMOD**750 +OK 747 747 748 -[[image:image-20220607153759-6.png]] 752 +the mode is 0 = No interruption 753 +))) 754 +|AT+INTMOD=2|((( 755 +Set Transmit Interval 749 749 757 +1. (Disable Interrupt), 758 +1. (Trigger by rising and falling edge), 759 +1. (Trigger by falling edge) 760 +1. (Trigger by rising edge) 761 +)))|OK 750 750 751 - (% style="color:#037691" %)**Downlink Command: 0x06**763 +**Downlink Command: 0x06** 752 752 753 753 Format: Command Code (0x06) followed by 3 bytes. 754 754 ... ... @@ -757,19 +757,20 @@ 757 757 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 758 758 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 759 759 760 -== 3.3 Calibrate Sensor == 772 +1. 773 +11. Calibrate Sensor 761 761 762 -Detail See [[Calibration Guide>> ||anchor="2.7Calibration"]] for the user of 0x13 and 0x14 downlink commands775 +Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands 763 763 764 764 765 765 779 +1. 780 +11. Get Firmware Version Info 766 766 767 -== 3.4 Get Firmware Version Info == 768 - 769 769 Feature: use downlink to get firmware version. 770 770 771 771 772 - (% style="color:#037691" %)**Downlink Command: 0x26**785 +**Downlink Command: 0x26** 773 773 774 774 775 775 |**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)**
- image-20220607153759-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -17.2 KB - Content