Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -428,7 +428,6 @@ 428 428 ))) 429 429 430 430 431 - 432 432 User can also send 0x14 downlink command to poll the current calibration payload. 433 433 434 434 [[image:image-20220607145603-4.png]] ... ... @@ -436,6 +436,7 @@ 436 436 * Reply to the confirmation package: 14 01 437 437 * Reply to non-confirmed packet: 14 00 438 438 438 + 439 439 == 2.8 Frequency Plans == 440 440 441 441 ((( ... ... @@ -491,6 +491,7 @@ 491 491 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 492 492 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 493 493 494 + 494 494 === 2.8.3 CN470-510 (CN470) === 495 495 496 496 Used in China, Default use CHE=1 ... ... @@ -557,6 +557,7 @@ 557 557 * Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 558 558 * Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 559 559 561 + 560 560 === 2.8.5 AS920-923 & AS923-925 (AS923) === 561 561 562 562 (% style="color:blue" %)**Default Uplink channel:** ... ... @@ -670,35 +670,30 @@ 670 670 * The sensor is detected when the device is turned on, and it will flash 4 times quickly when it is detected. 671 671 * Blink once when device transmit a packet. 672 672 675 + 673 673 == 2.10 Firmware Change Log == 674 674 678 + 675 675 **Firmware download link:** 676 676 677 677 [[http:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 678 678 679 679 680 -**Firmware Upgrade Method:[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] **684 +**Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 681 681 682 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction>>url:http://wiki.dragino.com/index.php?title=Firmware_Upgrade_Instruction_for_STM32_base_products#Introduction]] 683 683 684 684 688 += 3. Configure LSPH01 via AT Command or LoRaWAN Downlink = 685 685 686 - 687 - 688 - 689 -1. Configure LSPH01 via AT Command or LoRaWAN Downlink 690 - 691 691 Use can configure LSPH01 via AT Command or LoRaWAN Downlink. 692 692 693 -* AT Command Connection: See [[FAQ>> path:#AT_COMMAND]].694 -* LoRaWAN Downlink instruction for different platforms: 692 +* AT Command Connection: See [[FAQ>>||anchor="H6.FAQ"]]. 693 +* LoRaWAN Downlink instruction for different platforms: [[IoT LoRaWAN Server>>doc:Main.WebHome]] 695 695 696 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=Main_Page#Use_Note_for_Server>>url:http://wiki.dragino.com/index.php?title=Main_Page#Use_Note_for_Server]] 697 697 698 - 699 699 There are two kinds of commands to configure LSPH01, they are: 700 700 701 -* **General Commands**. 698 +* **(% style="color:#4F81BD" %) General Commands**. 702 702 703 703 These commands are to configure: 704 704 ... ... @@ -705,17 +705,15 @@ 705 705 * General system settings like: uplink interval. 706 706 * LoRaWAN protocol & radio related command. 707 707 708 -They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki: 705 +They are same for all Dragino Device which support DLWS-005 LoRaWAN Stack. These commands can be found on the wiki:[[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 709 709 710 -[[http:~~/~~/wiki.dragino.com/index.pHp?title=End_Device_Downlink_Command>>url:http://wiki.dragino.com/index.php?title=End_Device_Downlink_Command]] 711 711 708 +* **(% style="color:#4F81BD" %) Commands special design for LSPH01** 712 712 713 -* **Commands special design for LSPH01** 714 - 715 715 These commands only valid for LSPH01, as below: 716 716 717 717 718 -1. 713 +1. 719 719 11. Set Transmit Interval Time 720 720 721 721 Feature: Change LoRaWAN End Node Transmit Interval. ... ... @@ -745,7 +745,7 @@ 745 745 * Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 746 746 * Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 747 747 748 -1. 743 +1. 749 749 11. Set Interrupt Mode 750 750 751 751 Feature, Set Interrupt mode for GPIO_EXIT. ... ... @@ -778,7 +778,7 @@ 778 778 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 779 779 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 780 780 781 -1. 776 +1. 782 782 11. Calibrate Sensor 783 783 784 784 Detail See [[Calibration Guide>>path:#Calibration]] for the user of 0x13 and 0x14 downlink commands ... ... @@ -785,7 +785,7 @@ 785 785 786 786 787 787 788 -1. 783 +1. 789 789 11. Get Firmware Version Info 790 790 791 791 Feature: use downlink to get firmware version. ... ... @@ -894,7 +894,7 @@ 894 894 LSPH01: 2.45v ~~ 3.6v 895 895 896 896 897 -1. 892 +1. 898 898 11. Replace Battery 899 899 900 900 Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. ... ... @@ -903,7 +903,7 @@ 903 903 904 904 905 905 906 -1. 901 +1. 907 907 11. Power Consumption Analyze 908 908 909 909 Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. ... ... @@ -943,14 +943,14 @@ 943 943 944 944 945 945 1. 946 -11. 941 +11. 947 947 111. Battery Note 948 948 949 949 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 950 950 951 951 952 -1. 953 -11. 947 +1. 948 +11. 954 954 111. Replace the battery 955 955 956 956 You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.