Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -55,6 +55,8 @@ 55 55 * IP68 rate for the Sensor Probe 56 56 * 8500mAh Battery for long term use 57 57 58 + 59 + 58 58 == 1.3 Probe Specification == 59 59 60 60 ... ... @@ -75,10 +75,14 @@ 75 75 * IP68 Protection 76 76 * Length: 3.5 meters 77 77 80 + 81 + 78 78 == 1.4 Applications == 79 79 80 80 * Smart Agriculture 81 81 86 + 87 + 82 82 == 1.5 Pin mapping and power on == 83 83 84 84 [[image:1654580482666-473.png]] ... ... @@ -113,7 +113,7 @@ 113 113 ))) 114 114 115 115 ((( 116 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01.122 +**Step 1**: Create a device in TTN with the OTAA keys from LSPH01. 117 117 ))) 118 118 119 119 ((( ... ... @@ -150,7 +150,7 @@ 150 150 [[image:1654581517630-991.png]] 151 151 152 152 153 - (% style="color:blue" %)**Step 2**(%%): Power on LSPH01159 +**Step 2**: Power on LSPH01 154 154 155 155 156 156 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position). ... ... @@ -158,7 +158,7 @@ 158 158 [[image:image-20220607135918-2.png]] 159 159 160 160 161 - (% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel.167 +**Step 3:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 162 162 163 163 [[image:1654581590132-631.png]] 164 164 ... ... @@ -265,6 +265,8 @@ 265 265 |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 266 266 |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]] 267 267 274 + 275 + 268 268 === 2.3.7 Decode payload in The Things Network === 269 269 270 270 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -293,9 +293,9 @@ 293 293 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 294 294 295 295 296 - (% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.**304 +**Step 1: Be sure that your device is programmed and properly connected to the network at this time.** 297 297 298 - (% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:**306 +**Step 2: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:** 299 299 300 300 301 301 [[image:1654583683416-869.png]] ... ... @@ -304,9 +304,9 @@ 304 304 [[image:1654583694084-878.png]] 305 305 306 306 307 - (% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.**315 +**Step 3: Create an account or log in Datacake.** 308 308 309 - (% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.**317 +**Step 4: Create LSPH01 product.** 310 310 311 311 [[image:1654583711590-413.png]] 312 312 ... ... @@ -318,7 +318,7 @@ 318 318 [[image:1654583749683-259.png]] 319 319 320 320 321 - (% style="color:blue" %)**Step 5**(%%)**: add payload decode**329 +**Step 5: add payload decode** 322 322 323 323 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]] 324 324 ... ... @@ -340,65 +340,55 @@ 340 340 341 341 342 342 343 -== 2.6 Installation and Maintain == 351 +1. 352 +11. Installation and Maintain 353 +111. Before measurement 344 344 345 -=== 2.6.1 Before measurement === 346 - 347 -((( 348 348 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 349 -))) 350 350 351 351 358 +1. 359 +11. 360 +111. Measurement 352 352 353 - === 2.6.2Measurement===362 +**Measurement the soil surface** 354 354 355 355 356 - (%style="color:#4f81bd"%)**Measurement the soil surface:**365 +[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]] Choose the proper measuring position. Split the surface soil according to the measured deep. 357 357 358 -[[image:1654584128046-287.png]] 359 359 360 -Choose the proper measuring position. Split the surface soil according to the measured deep. 361 - 362 362 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 363 363 370 + 364 364 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting. 365 365 373 + 366 366 Put soil over the probe after insert. And start to measure. 367 367 368 368 369 - (% style="color:#4f81bd" %)**Measurement inside soil:**377 +**Measurement inside soil** 370 370 371 -Dig a hole with diameter > 20CM. 372 372 373 -Insert the probe inside, method like measure the surface. 374 374 381 +Dig a hole with diameter > 20CM. 375 375 376 376 377 - ===2.6.3MaintainProbe===384 +Insert the probe inside, method like measure the surface. 378 378 379 -1. ((( 380 -pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 381 -))) 382 -1. ((( 383 -After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 384 -))) 385 -1. ((( 386 -Probe reference electrode is also no strong, need to avoid strong force or hitting. 387 -))) 388 -1. ((( 389 -User should keep reference electrode wet while not use. 390 -))) 391 -1. ((( 392 -Avoid the probes to touch oily matter. Which will cause issue in accuracy. 393 -))) 394 -1. ((( 395 -The probe is IP68 can be put in water. 396 -))) 397 397 387 +1. 388 +11. 389 +111. Maintain Probe 390 +1111. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 391 +1111. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 392 +1111. Probe reference electrode is also no strong, need to avoid strong force or hitting. 393 +1111. User should keep reference electrode wet while not use. 394 +1111. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 395 +1111. The probe is IP68 can be put in water. 398 398 397 +1. 398 +11. Calibration 399 399 400 -2.7 Calibration 401 - 402 402 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 403 403 404 404
- 1654584128046-287.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -345.3 KB - Content