Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -55,7 +55,6 @@ 55 55 * IP68 rate for the Sensor Probe 56 56 * 8500mAh Battery for long term use 57 57 58 - 59 59 == 1.3 Probe Specification == 60 60 61 61 ... ... @@ -76,12 +76,10 @@ 76 76 * IP68 Protection 77 77 * Length: 3.5 meters 78 78 79 - 80 80 == 1.4 Applications == 81 81 82 82 * Smart Agriculture 83 83 84 - 85 85 == 1.5 Pin mapping and power on == 86 86 87 87 [[image:1654580482666-473.png]] ... ... @@ -269,6 +269,7 @@ 269 269 |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]] 270 270 271 271 269 + 272 272 === 2.3.7 Decode payload in The Things Network === 273 273 274 274 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -342,95 +342,77 @@ 342 342 343 343 344 344 343 +== 2.6 Installation and Maintain == 345 345 345 +=== 2.6.1 Before measurement === 346 346 347 -1. 348 -11. Installation and Maintain 349 -111. Before measurement 350 - 347 +((( 351 351 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 349 +))) 352 352 353 353 354 -1. 355 -11. 356 -111. Measurement 357 357 358 - **Measurementthe soil surface**353 +=== 2.6.2 Measurement === 359 359 360 360 361 - [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]] Choose the propermeasuring position.Splitthe surface soilaccording to the measured deep.356 +(% style="color:#4f81bd" %)**Measurement the soil surface:** 362 362 358 +[[image:1654584128046-287.png]] 363 363 360 +Choose the proper measuring position. Split the surface soil according to the measured deep. 361 + 364 364 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 365 365 366 - 367 367 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting. 368 368 369 - 370 370 Put soil over the probe after insert. And start to measure. 371 371 372 372 373 -**Measurement inside soil** 369 +(% style="color:#4f81bd" %)**Measurement inside soil:** 374 374 375 - 376 - 377 377 Dig a hole with diameter > 20CM. 378 378 379 - 380 380 Insert the probe inside, method like measure the surface. 381 381 382 382 383 -1. 384 -11. 385 -111. Maintain Probe 386 -1111. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 387 -1111. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 388 -1111. Probe reference electrode is also no strong, need to avoid strong force or hitting. 389 -1111. User should keep reference electrode wet while not use. 390 -1111. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 391 -1111. The probe is IP68 can be put in water. 392 392 393 -1. 394 -11. Calibration 377 +=== 2.6.3 Maintain Probe === 395 395 396 -User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 379 +1. ((( 380 +pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 381 +))) 382 +1. ((( 383 +After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 384 +))) 385 +1. ((( 386 +Probe reference electrode is also no strong, need to avoid strong force or hitting. 387 +))) 388 +1. ((( 389 +User should keep reference electrode wet while not use. 390 +))) 391 +1. ((( 392 +Avoid the probes to touch oily matter. Which will cause issue in accuracy. 393 +))) 394 +1. ((( 395 +The probe is IP68 can be put in water. 397 397 398 398 399 -**After stable, user can use below command to calibrate.** 398 + 399 +))) 400 400 401 +== 2.7 Calibration == 401 401 402 -|**pH buffer solution**|**AT Command to calibrate**|**Downlink Command**|**Read Cal Value** 403 -|**4.00**|**AT+PHCAL=4**|((( 404 -**0x13 04** 403 +User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 405 405 406 -**Reply with Calibrate payload** 407 -)))|((( 408 -**AT+PHCAL=?** 405 +After stable, user can use below command to calibrate. 409 409 410 -**Example 41,61,91** 411 -))) 412 -|**6.86**|**AT+PHCAL=6**|((( 413 -**0x13 06** 407 +[[image:image-20220607144936-3.png]] 414 414 415 -**Reply with Calibrate payload** 416 -)))|**AT+PHCAL=?** 417 -|**9.18**|**AT+PHCAL=9**|((( 418 -**0x13 09** 419 419 420 -**Reply with Calibrate payload** 421 -)))|**AT+PHCAL=?** 422 -|**Factory Default**|**AT+PHCAL=15**|((( 423 -**0x13 15** 424 424 425 -**Reply with Calibrate payload** 426 -)))|((( 427 -**AT+PHCAL=?** 411 +(% style="color:#037691" %)**Calibration Payload** 428 428 429 -**Example 151** 430 -))) 431 - 432 -Calibration Payload 433 - 413 +(% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 434 434 |((( 435 435 **Size** 436 436 ... ... @@ -445,25 +445,22 @@ 445 445 446 446 Calibrate value 447 447 )))|Reserve|((( 448 -[[Message>> path:#Message_Type]]428 +[[Message Type>>||anchor="H2.3.6MessageType"]] 449 449 450 -[[Type>>path:#Message_Type]] 451 - 452 452 Always 0x03 453 453 ))) 454 454 455 455 User can also send 0x14 downlink command to poll the current calibration payload. 456 456 435 +[[image:image-20220607145603-4.png]] 457 457 458 -|**Downlink Control Type**|**FPort**|**Type Code**|**Downlink payload size(bytes)** 459 -|Get Calibration Version Info|Any|14|2 460 - 461 461 * Reply to the confirmation package: 14 01 462 462 * Reply to non-confirmed packet: 14 00 463 463 464 -1. 465 -11. Frequency Plans 466 466 441 + 442 +Frequency Plans 443 + 467 467 The LSPH01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 468 468 469 469 1.
- 1654584128046-287.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +345.3 KB - Content
- image-20220607144936-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.6 KB - Content
- image-20220607145603-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +5.8 KB - Content