Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -55,8 +55,6 @@ 55 55 * IP68 rate for the Sensor Probe 56 56 * 8500mAh Battery for long term use 57 57 58 - 59 - 60 60 == 1.3 Probe Specification == 61 61 62 62 ... ... @@ -77,14 +77,10 @@ 77 77 * IP68 Protection 78 78 * Length: 3.5 meters 79 79 80 - 81 - 82 82 == 1.4 Applications == 83 83 84 84 * Smart Agriculture 85 85 86 - 87 - 88 88 == 1.5 Pin mapping and power on == 89 89 90 90 [[image:1654580482666-473.png]] ... ... @@ -119,7 +119,7 @@ 119 119 ))) 120 120 121 121 ((( 122 -**Step 1**: Create a device in TTN with the OTAA keys from LSPH01. 116 +(% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LSPH01. 123 123 ))) 124 124 125 125 ((( ... ... @@ -156,7 +156,7 @@ 156 156 [[image:1654581517630-991.png]] 157 157 158 158 159 -**Step 2**: Power on LSPH01 153 +(% style="color:blue" %)**Step 2**(%%): Power on LSPH01 160 160 161 161 162 162 Put a Jumper on JP2 to power on the device. ( The Switch must be in FLASH position). ... ... @@ -164,7 +164,7 @@ 164 164 [[image:image-20220607135918-2.png]] 165 165 166 166 167 -**Step 3:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 161 +(% style="color:blue" %)**Step 3**(%%)**:** The LSPH01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 168 168 169 169 [[image:1654581590132-631.png]] 170 170 ... ... @@ -271,8 +271,6 @@ 271 271 |0x02|Reply configures info|[[Configure Info Payload>>||anchor="H3.4GetFirmwareVersionInfo"]] 272 272 |0x03|Reply Calibration Info|[[Calibration Payload>>||anchor="H2.7Calibration"]] 273 273 274 - 275 - 276 276 === 2.3.7 Decode payload in The Things Network === 277 277 278 278 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -301,9 +301,9 @@ 301 301 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: 302 302 303 303 304 -**Step 1: Be sure that your device is programmed and properly connected to the network at this time.** 296 +(% style="color:blue" %)**Step 1**(%%)**: Be sure that your device is programmed and properly connected to the network at this time.** 305 305 306 -**Step 2: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:** 298 +(% style="color:blue" %)**Step 2**(%%)**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:** 307 307 308 308 309 309 [[image:1654583683416-869.png]] ... ... @@ -312,9 +312,9 @@ 312 312 [[image:1654583694084-878.png]] 313 313 314 314 315 -**Step 3: Create an account or log in Datacake.** 307 +(% style="color:blue" %)**Step 3**(%%)**: Create an account or log in Datacake.** 316 316 317 -**Step 4: Create LSPH01 product.** 309 +(% style="color:blue" %)**Step 4**(%%)**: Create LSPH01 product.** 318 318 319 319 [[image:1654583711590-413.png]] 320 320 ... ... @@ -326,7 +326,7 @@ 326 326 [[image:1654583749683-259.png]] 327 327 328 328 329 -**Step 5: add payload decode** 321 +(% style="color:blue" %)**Step 5**(%%)**: add payload decode** 330 330 331 331 Download Datacake decoder from: [[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/LSPH01/Decoder/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSNPK01/Decoder/]] 332 332 ... ... @@ -348,55 +348,65 @@ 348 348 349 349 350 350 351 -1. 352 -11. Installation and Maintain 353 -111. Before measurement 343 +== 2.6 Installation and Maintain == 354 354 345 +=== 2.6.1 Before measurement === 346 + 347 +((( 355 355 If the LSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 349 +))) 356 356 357 357 358 -1. 359 -11. 360 -111. Measurement 361 361 362 - **Measurementthe soil surface**353 +=== 2.6.2 Measurement === 363 363 364 364 365 - [[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image021.png]] Choose the propermeasuring position.Splitthe surface soilaccording to the measured deep.356 +(% style="color:#4f81bd" %)**Measurement the soil surface:** 366 366 358 +[[image:1654584128046-287.png]] 367 367 360 +Choose the proper measuring position. Split the surface soil according to the measured deep. 361 + 368 368 Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 369 369 370 - 371 371 Slowly insert the probe to the measure point. Don’t use large force which will break the probe. Make sure not shake when inserting. 372 372 373 - 374 374 Put soil over the probe after insert. And start to measure. 375 375 376 376 377 -**Measurement inside soil** 369 +(% style="color:#4f81bd" %)**Measurement inside soil:** 378 378 371 +Dig a hole with diameter > 20CM. 379 379 373 +Insert the probe inside, method like measure the surface. 380 380 381 -Dig a hole with diameter > 20CM. 382 382 383 383 384 - Inserttheprobeinside, method likemeasurethe surface.377 +=== 2.6.3 Maintain Probe === 385 385 379 +1. ((( 380 +pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 381 +))) 382 +1. ((( 383 +After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 384 +))) 385 +1. ((( 386 +Probe reference electrode is also no strong, need to avoid strong force or hitting. 387 +))) 388 +1. ((( 389 +User should keep reference electrode wet while not use. 390 +))) 391 +1. ((( 392 +Avoid the probes to touch oily matter. Which will cause issue in accuracy. 393 +))) 394 +1. ((( 395 +The probe is IP68 can be put in water. 396 +))) 386 386 387 -1. 388 -11. 389 -111. Maintain Probe 390 -1111. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 391 -1111. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 392 -1111. Probe reference electrode is also no strong, need to avoid strong force or hitting. 393 -1111. User should keep reference electrode wet while not use. 394 -1111. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 395 -1111. The probe is IP68 can be put in water. 396 396 397 -1. 398 -11. Calibration 399 399 400 +2.7 Calibration 401 + 400 400 User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 401 401 402 402
- 1654584128046-287.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +345.3 KB - Content