Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Xiaoling on 2025/04/27 13:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -80,6 +80,7 @@ 80 80 * 8500mAh Battery for long term use 81 81 82 82 83 + 83 83 == 1.3 Specification == 84 84 85 85 === 1.3.1 Rated environmental conditions === ... ... @@ -126,6 +126,7 @@ 126 126 * Bottom water level monitoring 127 127 128 128 130 + 129 129 == 1.6 Pin mapping and power on == 130 130 131 131 ... ... @@ -295,7 +295,6 @@ 295 295 * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor. 296 296 * If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00. 297 297 298 - 299 299 === 2.3.3 Interrupt Pin === 300 300 301 301 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.3A0SetInterruptMode"]] for the hardware and software set up. ... ... @@ -873,7 +873,6 @@ 873 873 * Solid ON for 5 seconds once device successful Join the network. 874 874 * Blink once when device transmit a packet. 875 875 876 - 877 877 == 2.8 Firmware Change Log == 878 878 879 879 ... ... @@ -987,12 +987,12 @@ 987 987 === 3.3.2 Replace the battery === 988 988 989 989 ((( 990 -You can change the battery in the L DDS45.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.990 +You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board. 991 991 ))) 992 992 993 993 994 994 ((( 995 -The default battery pack of L DDS45includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).995 +The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user can’t find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 996 996 ))) 997 997 998 998 ... ... @@ -1091,7 +1091,7 @@ 1091 1091 1092 1092 1093 1093 ((( 1094 -In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS 45. LDDS45 will output system info once power on as below:1094 +In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LDDS75. LDDS75 will output system info once power on as below: 1095 1095 ))) 1096 1096 1097 1097 (% aria-label="image widget" contenteditable="false" role="region" tabindex="-1" %)[[image:1654917321722-210.png||data-widget="image"]](% title="Click and drag to resize" %) ... ... @@ -1148,7 +1148,6 @@ 1148 1148 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1149 1149 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1150 1150 1151 - 1152 1152 = 5. FAQ = 1153 1153 1154 1154 == 5.1 What is the frequency plan for LDDS45? == ... ... @@ -1192,7 +1192,6 @@ 1192 1192 * (% style="color:red" %)**IN865 **(%%)**:** LoRaWAN IN865 band 1193 1193 * (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band 1194 1194 1195 - 1196 1196 = 8. Packing Info = 1197 1197 1198 1198 ... ... @@ -1207,7 +1207,6 @@ 1207 1207 * Package Size / pcs : cm 1208 1208 * Weight / pcs : g 1209 1209 1210 - 1211 1211 = 9. Support = 1212 1212 1213 1213 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.