Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Xiaoling on 2025/04/27 13:54
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,7 +25,6 @@ 25 25 26 26 = 1. Introduction = 27 27 28 - 29 29 == 1.1 What is LoRaWAN Distance Detection Sensor == 30 30 31 31 ((( ... ... @@ -269,10 +269,11 @@ 269 269 270 270 (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %) 271 271 |=(% style="width: 62.5px;" %)((( 272 -**Size(bytes)** 271 +**Size (bytes)** 273 273 )))|=(% style="width: 62.5px;" %)**2**|=**2**|=1|=2|=**1** 274 274 |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|((( 275 275 [[Distance>>||anchor="H2.3.2A0Distance"]] 275 + 276 276 (unit: mm) 277 277 )))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|((( 278 278 [[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]] ... ... @@ -301,9 +301,7 @@ 301 301 ))) 302 302 303 303 ((( 304 -For example, if the data you get from the register is __0x0B 0x05__, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** ** 305 - 306 -(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.** 304 +For example, if the data you get from the register is __0x0B 0x05__, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.** 307 307 ))) 308 308 309 309 ... ... @@ -325,6 +325,7 @@ 325 325 326 326 327 327 326 + 328 328 === 2.3.4 DS18B20 Temperature sensor === 329 329 330 330 ... ... @@ -430,8 +430,6 @@ 430 430 === 2.6.1 EU863-870 (EU868) === 431 431 432 432 ((( 433 - 434 - 435 435 (% style="color:blue" %)**Uplink:** 436 436 ))) 437 437 ... ... @@ -908,6 +908,7 @@ 908 908 909 909 910 910 908 + 911 911 == 2.8 Firmware Change Log == 912 912 913 913 ... ... @@ -1159,8 +1159,8 @@ 1159 1159 If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01. 1160 1160 ))) 1161 1161 1162 -* Example 1: Downlink Payload: 0100001E 1163 -* Example 2: Downlink Payload: 0100003C 1160 +* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds 1161 +* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds 1164 1164 ))) 1165 1165 ))) 1166 1166 ... ... @@ -1185,11 +1185,12 @@ 1185 1185 This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06. 1186 1186 ))) 1187 1187 1188 -* Example 1: Downlink Payload: 06000000 1189 -* Example 2: Downlink Payload: 06000003 1186 +* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1187 +* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1190 1190 1191 1191 1192 1192 1191 + 1193 1193 = 5. FAQ = 1194 1194 1195 1195 ... ... @@ -1240,6 +1240,7 @@ 1240 1240 1241 1241 1242 1242 1242 + 1243 1243 = 8. Packing Info = 1244 1244 1245 1245 ... ... @@ -1256,6 +1256,7 @@ 1256 1256 1257 1257 1258 1258 1259 + 1259 1259 = 9. Support = 1260 1260 1261 1261