Summary

Details

Page properties
Content
... ... @@ -25,6 +25,7 @@
25 25  
26 26  = 1.  Introduction =
27 27  
28 +
28 28  == 1.1 ​ What is LoRaWAN Distance Detection Sensor ==
29 29  
30 30  (((
... ... @@ -268,11 +268,10 @@
268 268  
269 269  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:510px" %)
270 270  |=(% style="width: 62.5px;" %)(((
271 -**Size (bytes)**
272 +**Size(bytes)**
272 272  )))|=(% style="width: 62.5px;" %)**2**|=**2**|=1|=2|=**1**
273 273  |(% style="width:62.5px" %)**Value**|(% style="width:62.5px" %)[[BAT>>||anchor="H2.3.1A0BatteryInfo"]]|(((
274 274  [[Distance>>||anchor="H2.3.2A0Distance"]]
275 -
276 276  (unit: mm)
277 277  )))|[[Digital Interrupt (Optional)>>||anchor="H2.3.3A0InterruptPin"]]|(((
278 278  [[Temperature (Optional )>>||anchor="H2.3.4A0DS18B20Temperaturesensor"]]
... ... @@ -301,7 +301,9 @@
301 301  )))
302 302  
303 303  (((
304 -For example, if the data you get from the register is __0x0B 0x05__, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** 0B05(H) = 2821 (D) = 2821 mm.**
304 +For example, if the data you get from the register is __0x0B 0x05__, the distance between the sensor and the measured object is(% style="color:#4472c4" %)** **
305 +
306 +(% style="color:#4472c4" %)**0B05(H) = 2821 (D) = 2821 mm.**
305 305  )))
306 306  
307 307  
... ... @@ -323,7 +323,6 @@
323 323  
324 324  
325 325  
326 -
327 327  === 2.3.4  DS18B20 Temperature sensor ===
328 328  
329 329  
... ... @@ -429,6 +429,8 @@
429 429  === 2.6.1  EU863-870 (EU868) ===
430 430  
431 431  (((
433 +
434 +
432 432  (% style="color:blue" %)**Uplink:**
433 433  )))
434 434  
... ... @@ -905,7 +905,6 @@
905 905  
906 906  
907 907  
908 -
909 909  == 2.8  ​Firmware Change Log ==
910 910  
911 911  
... ... @@ -1157,8 +1157,8 @@
1157 1157  If the downlink payload=0100003C, it means set the END Node's Transmit Interval to 0x00003C=60(S), while type code is 01.
1158 1158  )))
1159 1159  
1160 -* Example 1: Downlink Payload: 0100001E ~/~/ Set Transmit Interval (TDC) = 30 seconds
1161 -* Example 2: Downlink Payload: 0100003C ~/~/ Set Transmit Interval (TDC) = 60 seconds
1162 +* Example 1: Downlink Payload: 0100001E  ~/~/ Set Transmit Interval (TDC) = 30 seconds
1163 +* Example 2: Downlink Payload: 0100003C  ~/~/ Set Transmit Interval (TDC) = 60 seconds
1162 1162  )))
1163 1163  )))
1164 1164  
... ... @@ -1183,12 +1183,11 @@
1183 1183  This means that the interrupt mode of the end node is set to 0x000003=3 (rising edge trigger), and the type code is 06.
1184 1184  )))
1185 1185  
1186 -* Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1187 -* Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1188 +* Example 1: Downlink Payload: 06000000  ~/~/ Turn off interrupt mode
1189 +* Example 2: Downlink Payload: 06000003  ~/~/ Set the interrupt mode to rising edge trigger
1188 1188  
1189 1189  
1190 1190  
1191 -
1192 1192  = 5.  FAQ =
1193 1193  
1194 1194  
... ... @@ -1239,7 +1239,6 @@
1239 1239  
1240 1240  
1241 1241  
1242 -
1243 1243  = 8. ​ Packing Info =
1244 1244  
1245 1245  
... ... @@ -1256,7 +1256,6 @@
1256 1256  
1257 1257  
1258 1258  
1259 -
1260 1260  = 9.  ​Support =
1261 1261  
1262 1262