From version < 162.12 >
edited by Xiaoling
on 2022/06/11 11:28
To version < 162.8 >
edited by Xiaoling
on 2022/06/11 11:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -97,6 +97,7 @@
97 97  * IP66 Waterproof Enclosure
98 98  * 8500mAh Battery for long term use
99 99  
100 +
100 100  == 1.3  Specification ==
101 101  
102 102  === 1.3.1  Rated environmental conditions ===
... ... @@ -143,6 +143,7 @@
143 143  * Sewer
144 144  * Bottom water level monitoring
145 145  
147 +
146 146  == 1.6  Pin mapping and power on ==
147 147  
148 148  
... ... @@ -302,6 +302,7 @@
302 302  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
303 303  * If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00.
304 304  
307 +
305 305  === 2.3.3  Interrupt Pin ===
306 306  
307 307  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -875,6 +875,7 @@
875 875  * Solid ON for 5 seconds once device successful Join the network.
876 876  * Blink once when device transmit a packet.
877 877  
881 +
878 878  == 2.8  ​Firmware Change Log ==
879 879  
880 880  
... ... @@ -1152,11 +1152,12 @@
1152 1152  
1153 1153  
1154 1154  
1159 +
1155 1155  = 5.  FAQ =
1156 1156  
1157 -== 5.1  What is the frequency plan for LDDS45? ==
1162 +== 5.1  What is the frequency plan for LDDS75? ==
1158 1158  
1159 -LDDS45 use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
1164 +LDDS75 use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
1160 1160  
1161 1161  
1162 1162  
... ... @@ -1167,10 +1167,21 @@
1167 1167  
1168 1168  
1169 1169  
1175 +== 5.3  Can I use LDDS75 in condensation environment? ==
1176 +
1177 +LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0.
1178 +
1179 +
1180 +
1170 1170  = 6.  Trouble Shooting =
1171 1171  
1172 -== 6.1  AT Command input doesn't work ==
1183 +== 6.1  Why I can’t join TTN V3 in US915 / AU915 bands? ==
1173 1173  
1185 +It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1186 +
1187 +
1188 +== 6.2  AT Command input doesn't work ==
1189 +
1174 1174  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1175 1175  
1176 1176  (((