<
From version < 162.10 >
edited by Xiaoling
on 2022/06/11 11:25
To version < 163.7 >
edited by Xiaoling
on 2022/06/11 13:52
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -13,6 +13,7 @@
13 13  
14 14  **Contents:**
15 15  
16 +{{toc/}}
16 16  
17 17  
18 18  
... ... @@ -21,6 +21,7 @@
21 21  
22 22  
23 23  
25 +
24 24  = 1.  Introduction =
25 25  
26 26  == 1.1 ​ What is LoRaWAN Distance Detection Sensor ==
... ... @@ -97,6 +97,9 @@
97 97  * IP66 Waterproof Enclosure
98 98  * 8500mAh Battery for long term use
99 99  
102 +
103 +
104 +
100 100  == 1.3  Specification ==
101 101  
102 102  === 1.3.1  Rated environmental conditions ===
... ... @@ -143,6 +143,9 @@
143 143  * Sewer
144 144  * Bottom water level monitoring
145 145  
151 +
152 +
153 +
146 146  == 1.6  Pin mapping and power on ==
147 147  
148 148  
... ... @@ -302,6 +302,9 @@
302 302  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
303 303  * If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00.
304 304  
313 +
314 +
315 +
305 305  === 2.3.3  Interrupt Pin ===
306 306  
307 307  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -1008,7 +1008,7 @@
1008 1008  
1009 1009  * (((
1010 1010  (((
1011 -AT Command Connection: See [[FAQ>>||anchor="H4.A0FAQ"]].
1022 +AT Command Connection: See [[FAQ>>||anchor="H5.A0FAQ"]].
1012 1012  )))
1013 1013  )))
1014 1014  * (((
... ... @@ -1151,7 +1151,6 @@
1151 1151  
1152 1152  
1153 1153  
1154 -
1155 1155  = 5.  FAQ =
1156 1156  
1157 1157  == 5.1  What is the frequency plan for LDDS45? ==
... ... @@ -1167,21 +1167,10 @@
1167 1167  
1168 1168  
1169 1169  
1170 -== 5.3  Can I use LDDS75 in condensation environment? ==
1171 -
1172 -LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0.
1173 -
1174 -
1175 -
1176 1176  = 6.  Trouble Shooting =
1177 1177  
1178 -== 6.1  Why I can’t join TTN V3 in US915 / AU915 bands? ==
1182 +== 6.1  AT Command input doesn't work ==
1179 1179  
1180 -It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1181 -
1182 -
1183 -== 6.2  AT Command input doesn't work ==
1184 -
1185 1185  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1186 1186  
1187 1187  (((
... ... @@ -1192,7 +1192,7 @@
1192 1192  = 7.  Order Info =
1193 1193  
1194 1194  
1195 -Part Number **:** (% style="color:blue" %)**LDDS75-XX-YY**
1194 +Part Number **:** (% style="color:blue" %)**LDDS45-XX**
1196 1196  
1197 1197  
1198 1198  (% style="color:blue" %)**XX**(%%)**: **The default frequency band
... ... @@ -1206,10 +1206,7 @@
1206 1206  * (% style="color:red" %)**IN865 **(%%)**:**  LoRaWAN IN865 band
1207 1207  * (% style="color:red" %)**CN470 **(%%)**:** LoRaWAN CN470 band
1208 1208  
1209 -(% style="color:blue" %)**YY**(%%): Battery Option
1210 1210  
1211 -* (% style="color:red" %)**4 **(%%)**: **4000mAh battery
1212 -* (% style="color:red" %)**8 **(%%)**:** 8500mAh battery
1213 1213  
1214 1214  = 8. ​ Packing Info =
1215 1215  
... ... @@ -1216,7 +1216,7 @@
1216 1216  
1217 1217  **Package Includes**:
1218 1218  
1219 -* LDDS75 LoRaWAN Distance Detection Sensor x 1
1215 +* LDDS45 LoRaWAN Distance Detection Sensor x 1
1220 1220  
1221 1221  **Dimension and weight**:
1222 1222  
... ... @@ -1225,6 +1225,8 @@
1225 1225  * Package Size / pcs : cm
1226 1226  * Weight / pcs : g
1227 1227  
1224 +
1225 +
1228 1228  = 9.  ​Support =
1229 1229  
1230 1230  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0