Changes for page LDDS45 - LoRaWAN Distance Detection Sensor User Manual
Last modified by Mengting Qiu on 2025/02/26 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -71,6 +71,7 @@ 71 71 72 72 73 73 74 + 74 74 == 1.2 Features == 75 75 76 76 * LoRaWAN 1.0.3 Class A ... ... @@ -88,8 +88,6 @@ 88 88 * 8500mAh Battery for long term use 89 89 90 90 91 - 92 - 93 93 == 1.3 Specification == 94 94 95 95 === 1.3.1 Rated environmental conditions === ... ... @@ -137,8 +137,6 @@ 137 137 * Bottom water level monitoring 138 138 139 139 140 - 141 - 142 142 == 1.6 Pin mapping and power on == 143 143 144 144 ... ... @@ -299,8 +299,6 @@ 299 299 * If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00. 300 300 301 301 302 - 303 - 304 304 === 2.3.3 Interrupt Pin === 305 305 306 306 This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.3A0SetInterruptMode"]] for the hardware and software set up. ... ... @@ -875,8 +875,6 @@ 875 875 * Blink once when device transmit a packet. 876 876 877 877 878 - 879 - 880 880 == 2.8 Firmware Change Log == 881 881 882 882 ... ... @@ -903,66 +903,14 @@ 903 903 904 904 905 905 906 -= 3. Battery & How to replace = 907 907 908 -== 3.1 BatteryType==900 +== 2.10 Battery Analysis == 909 909 910 -((( 911 -LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter. 912 -))) 902 +=== 2.10.1 Battery Type === 913 913 914 -((( 915 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance. 916 -))) 904 +The LDDS75 battery is a combination of a 4000mAh or 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 917 917 918 -[[image:1654593587246-335.png]] 919 919 920 - 921 -Minimum Working Voltage for the LSPH01: 922 - 923 -LSPH01: 2.45v ~~ 3.6v 924 - 925 - 926 - 927 -== 3.2 Replace Battery == 928 - 929 -((( 930 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery. 931 -))) 932 - 933 -((( 934 -And make sure the positive and negative pins match. 935 -))) 936 - 937 - 938 - 939 -== 3.3 Power Consumption Analyze == 940 - 941 -((( 942 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 943 -))) 944 - 945 -((( 946 -Instruction to use as below: 947 -))) 948 - 949 - 950 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: 951 - 952 -[[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 953 - 954 - 955 -**Step 2**: Open it and choose 956 - 957 -* Product Model 958 -* Uplink Interval 959 -* Working Mode 960 - 961 -And the Life expectation in difference case will be shown on the right. 962 - 963 -[[image:1654593605679-189.png]] 964 - 965 - 966 966 The battery related documents as below: 967 967 968 968 * ((( ... ... @@ -975,33 +975,28 @@ 975 975 [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 976 976 ))) 977 977 978 -[[image:image-2022060 7172042-11.png]]919 + [[image:image-20220610172400-3.png]] 979 979 980 980 981 981 982 -=== 3.3.1BatteryNote===923 +=== 2.10.2 Replace the battery === 983 983 984 984 ((( 985 - TheLi-SICObattery isdesignedfor smallcurrent/long period application.It isnotgoodtouseahigh current,shortperiodtransmitmethod.Thecommendedminimumperiodforuseofthisbatteryis5minutes. If you use ashorter period time totransmitLoRa,then the batterylifemaybe decreased.926 +You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 986 986 ))) 987 987 988 - 989 - 990 -=== 3.3.2 Replace the battery === 991 - 992 992 ((( 993 - Youcan change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.930 + 994 994 ))) 995 995 996 996 ((( 997 -The default battery pack of LS PH01includes a ER26500plus super capacitor. If user can’t find this pack locally, they can find ER26500or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)934 +The default battery pack of LDDS75 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes) 998 998 ))) 999 999 1000 1000 1001 1001 939 += 3. Configure LDDS75 via AT Command or LoRaWAN Downlink = 1002 1002 1003 -= 4. Configure LDDS75 via AT Command or LoRaWAN Downlink = 1004 - 1005 1005 ((( 1006 1006 ((( 1007 1007 Use can configure LDDS75 via AT Command or LoRaWAN Downlink. ... ... @@ -1078,7 +1078,7 @@ 1078 1078 1079 1079 1080 1080 1081 -== 4.1 Access AT Commands ==1017 +== 3.1 Access AT Commands == 1082 1082 1083 1083 LDDS75 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS75 for using AT command, as below. 1084 1084 ... ... @@ -1100,7 +1100,7 @@ 1100 1100 1101 1101 1102 1102 1103 -== 4.2 Set Transmit Interval Time ==1039 +== 3.2 Set Transmit Interval Time == 1104 1104 1105 1105 Feature: Change LoRaWAN End Node Transmit Interval. 1106 1106 ... ... @@ -1130,7 +1130,7 @@ 1130 1130 1131 1131 1132 1132 1133 -== 4.3 Set Interrupt Mode ==1069 +== 3.3 Set Interrupt Mode == 1134 1134 1135 1135 Feature, Set Interrupt mode for GPIO_EXIT. 1136 1136 ... ... @@ -1150,15 +1150,16 @@ 1150 1150 * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode 1151 1151 * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger 1152 1152 1153 -= 5. FAQ = 1154 1154 1155 -= =5.1Whatis the frequency plan for LDDS75?==1090 += 4. FAQ = 1156 1156 1092 +== 4.1 What is the frequency plan for LDDS75? == 1093 + 1157 1157 LDDS75 use the same frequency as other Dragino products. User can see the detail from this link: [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]] 1158 1158 1159 1159 1160 1160 1161 -== 5.2 How to change the LoRa Frequency Bands/Region ==1098 +== 4.2 How to change the LoRa Frequency Bands/Region == 1162 1162 1163 1163 You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]]. 1164 1164 When downloading the images, choose the required image file for download. ... ... @@ -1165,20 +1165,20 @@ 1165 1165 1166 1166 1167 1167 1168 -== 5.3 Can I use LDDS75 in condensation environment? ==1105 +== 4.3 Can I use LDDS75 in condensation environment? == 1169 1169 1170 1170 LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0. 1171 1171 1172 1172 1173 1173 1174 -= 6. Trouble Shooting =1111 += 5. Trouble Shooting = 1175 1175 1176 -== 6.1 Why I can’t join TTN V3 in US915 / AU915 bands? ==1113 +== 5.1 Why I can’t join TTN V3 in US915 / AU915 bands? == 1177 1177 1178 1178 It is due to channel mapping. Please see below link: [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] 1179 1179 1180 1180 1181 -== 6.2 AT Command input doesn't work ==1118 +== 5.2 AT Command input doesn't work == 1182 1182 1183 1183 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 1184 1184 ... ... @@ -1187,7 +1187,7 @@ 1187 1187 ))) 1188 1188 1189 1189 1190 -= 7. Order Info =1127 += 6. Order Info = 1191 1191 1192 1192 1193 1193 Part Number **:** (% style="color:blue" %)**LDDS75-XX-YY** ... ... @@ -1209,9 +1209,10 @@ 1209 1209 * (% style="color:red" %)**4 **(%%)**: **4000mAh battery 1210 1210 * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery 1211 1211 1212 -= 8. Packing Info = 1213 1213 1150 += 7. Packing Info = 1214 1214 1152 + 1215 1215 **Package Includes**: 1216 1216 1217 1217 * LDDS75 LoRaWAN Distance Detection Sensor x 1 ... ... @@ -1223,7 +1223,8 @@ 1223 1223 * Package Size / pcs : cm 1224 1224 * Weight / pcs : g 1225 1225 1226 -= 9. Support = 1227 1227 1165 += 8. Support = 1166 + 1228 1228 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1229 1229 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].