From version < 159.5 >
edited by Xiaoling
on 2022/06/11 10:57
To version < 159.2 >
edited by Xiaoling
on 2022/06/11 10:46
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -71,6 +71,7 @@
71 71  
72 72  
73 73  
74 +
74 74  == ​1.2  Features ==
75 75  
76 76  * LoRaWAN 1.0.3 Class A
... ... @@ -88,9 +88,6 @@
88 88  * 8500mAh Battery for long term use
89 89  
90 90  
91 -
92 -
93 -
94 94  == 1.3  Specification ==
95 95  
96 96  === 1.3.1  Rated environmental conditions ===
... ... @@ -138,9 +138,6 @@
138 138  * Bottom water level monitoring
139 139  
140 140  
141 -
142 -
143 -
144 144  == 1.6  Pin mapping and power on ==
145 145  
146 146  
... ... @@ -300,6 +300,7 @@
300 300  * If the sensor value is 0x0000, it means system doesn’t detect ultrasonic sensor.
301 301  * If the sensor value lower than 0x001E (30mm), the sensor value will be 0x00.
302 302  
298 +
303 303  === 2.3.3  Interrupt Pin ===
304 304  
305 305  This data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H4.3A0SetInterruptMode"]] for the hardware and software set up.
... ... @@ -873,6 +873,7 @@
873 873  * Solid ON for 5 seconds once device successful Join the network.
874 874  * Blink once when device transmit a packet.
875 875  
872 +
876 876  == 2.8  ​Firmware Change Log ==
877 877  
878 878  
... ... @@ -899,66 +899,14 @@
899 899  
900 900  
901 901  
902 -= 3. Battery & How to replace =
903 903  
904 -== 3.1 Battery Type ==
900 +== 2.1 Battery Analysis ==
905 905  
906 -(((
907 -LSPH01 is equipped with a [[8500mAH ER26500 Li-SOCI2 battery>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]. The battery is un-rechargeable battery with low discharge rate targeting for 8~~10 years use. This type of battery is commonly used in IoT target for long-term running, such as water meter.
908 -)))
902 +=== 2.10.1  Battery Type ===
909 909  
910 -(((
911 -The discharge curve is not linear so can’t simply use percentage to show the battery level. Below is the battery performance.
912 -)))
904 +The LDDS75 battery is a combination of a 4000mAh or 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
913 913  
914 -[[image:1654593587246-335.png]]
915 915  
916 -
917 -Minimum Working Voltage for the LSPH01:
918 -
919 -LSPH01:  2.45v ~~ 3.6v
920 -
921 -
922 -
923 -== 3.2 Replace Battery ==
924 -
925 -(((
926 -Any battery with range 2.45 ~~ 3.6v can be a replacement. We recommend to use Li-SOCl2 Battery.
927 -)))
928 -
929 -(((
930 -And make sure the positive and negative pins match.
931 -)))
932 -
933 -
934 -
935 -== 3.3 Power Consumption Analyze ==
936 -
937 -(((
938 -Dragino Battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
939 -)))
940 -
941 -(((
942 -Instruction to use as below:
943 -)))
944 -
945 -
946 -**Step 1**: Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from:
947 -
948 -[[https:~~/~~/www.dragino.com/downloads/index.pHp?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
949 -
950 -
951 -**Step 2**: Open it and choose
952 -
953 -* Product Model
954 -* Uplink Interval
955 -* Working Mode
956 -
957 -And the Life expectation in difference case will be shown on the right.
958 -
959 -[[image:1654593605679-189.png]]
960 -
961 -
962 962  The battery related documents as below:
963 963  
964 964  * (((
... ... @@ -971,33 +971,28 @@
971 971  [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
972 972  )))
973 973  
974 -[[image:image-20220607172042-11.png]]
919 + [[image:image-20220610172400-3.png]]
975 975  
976 976  
977 977  
978 -=== 3.3.1 ​Battery Note ===
923 +=== 2.10.2  Replace the battery ===
979 979  
980 980  (((
981 -The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
926 +You can change the battery in the LDDS75.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
982 982  )))
983 983  
984 -
985 -
986 -=== ​3.3.2 Replace the battery ===
987 -
988 988  (((
989 -You can change the battery in the LSPH01.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won’t be voltage drop between battery and main board.
930 +
990 990  )))
991 991  
992 992  (((
993 -The default battery pack of LSPH01 includes a ER26500 plus super capacitor. If user cant find this pack locally, they can find ER26500 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
934 +The default battery pack of LDDS75 includes a ER18505 plus super capacitor. If user can't find this pack locally, they can find ER18505 or equivalence, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes)
994 994  )))
995 995  
996 996  
997 997  
939 += 3.  Configure LDDS75 via AT Command or LoRaWAN Downlink =
998 998  
999 -= 4.  Configure LDDS75 via AT Command or LoRaWAN Downlink =
1000 -
1001 1001  (((
1002 1002  (((
1003 1003  Use can configure LDDS75 via AT Command or LoRaWAN Downlink.
... ... @@ -1074,7 +1074,7 @@
1074 1074  
1075 1075  
1076 1076  
1077 -== 4.1  Access AT Commands ==
1017 +== 3.1  Access AT Commands ==
1078 1078  
1079 1079  LDDS75 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LDDS75 for using AT command, as below.
1080 1080  
... ... @@ -1096,7 +1096,7 @@
1096 1096  
1097 1097  
1098 1098  
1099 -== 4.2  Set Transmit Interval Time ==
1039 +== 3.2  Set Transmit Interval Time ==
1100 1100  
1101 1101  Feature: Change LoRaWAN End Node Transmit Interval.
1102 1102  
... ... @@ -1126,7 +1126,7 @@
1126 1126  
1127 1127  
1128 1128  
1129 -== 4.3  Set Interrupt Mode ==
1069 +== 3.3  Set Interrupt Mode ==
1130 1130  
1131 1131  Feature, Set Interrupt mode for GPIO_EXIT.
1132 1132  
... ... @@ -1146,15 +1146,16 @@
1146 1146  * Example 1: Downlink Payload: 06000000 ~/~/ Turn off interrupt mode
1147 1147  * Example 2: Downlink Payload: 06000003 ~/~/ Set the interrupt mode to rising edge trigger
1148 1148  
1149 -= 5.  FAQ =
1150 1150  
1151 -== 5.1  What is the frequency plan for LDDS75? ==
1090 += 4FAQ =
1152 1152  
1092 +== 4.1  What is the frequency plan for LDDS75? ==
1093 +
1153 1153  LDDS75 use the same frequency as other Dragino products. User can see the detail from this link:  [[Introduction>>doc:Main.End Device Frequency Band.WebHome||anchor="H1.Introduction"]]
1154 1154  
1155 1155  
1156 1156  
1157 -== 5.2  How to change the LoRa Frequency Bands/Region ==
1098 +== 4.2  How to change the LoRa Frequency Bands/Region ==
1158 1158  
1159 1159  You can follow the instructions for [[how to upgrade image>>||anchor="H2.8A0200BFirmwareChangeLog"]].
1160 1160  When downloading the images, choose the required image file for download. ​
... ... @@ -1161,20 +1161,20 @@
1161 1161  
1162 1162  
1163 1163  
1164 -== 5.3  Can I use LDDS75 in condensation environment? ==
1105 +== 4.3  Can I use LDDS75 in condensation environment? ==
1165 1165  
1166 1166  LDDS75 is not suitable to be used in condensation environment. Condensation on the LDDS75 probe will affect the reading and always got 0.
1167 1167  
1168 1168  
1169 1169  
1170 -= 6.  Trouble Shooting =
1111 += 5.  Trouble Shooting =
1171 1171  
1172 -== 6.1  Why I can’t join TTN V3 in US915 / AU915 bands? ==
1113 +== 5.1  Why I can’t join TTN V3 in US915 / AU915 bands? ==
1173 1173  
1174 1174  It is due to channel mapping. Please see below link:  [[Frequency band>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]]
1175 1175  
1176 1176  
1177 -== 6.2  AT Command input doesn't work ==
1118 +== 5.2  AT Command input doesn't work ==
1178 1178  
1179 1179  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1180 1180  
... ... @@ -1183,7 +1183,7 @@
1183 1183  )))
1184 1184  
1185 1185  
1186 -= 7.  Order Info =
1127 += 6.  Order Info =
1187 1187  
1188 1188  
1189 1189  Part Number **:** (% style="color:blue" %)**LDDS75-XX-YY**
... ... @@ -1205,9 +1205,10 @@
1205 1205  * (% style="color:red" %)**4 **(%%)**: **4000mAh battery
1206 1206  * (% style="color:red" %)**8 **(%%)**:** 8500mAh battery
1207 1207  
1208 -= 8. ​ Packing Info =
1209 1209  
1150 += 7. ​ Packing Info =
1210 1210  
1152 +
1211 1211  **Package Includes**:
1212 1212  
1213 1213  * LDDS75 LoRaWAN Distance Detection Sensor x 1
... ... @@ -1219,7 +1219,8 @@
1219 1219  * Package Size / pcs : cm
1220 1220  * Weight / pcs : g
1221 1221  
1222 -= 9.  ​Support =
1223 1223  
1165 += 8.  ​Support =
1166 +
1224 1224  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1225 1225  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]].
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0